Volumn 16, Issue 1, 2000, Pages 13-21

Computerized left ventricular pressure-volume relationships (pV-loops) using disposable angiographic tip transducer pigtail catheters

Author keywords

Left ventricular angiogram; Millar pigtail catheter; Myocardial compliance; Pressure volume relationship

Indexed keywords

ANGIOGRAPHY; ANGIOPLASTY; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY DILATATION; DIGITAL COMPUTER; FUNCTIONAL ASSESSMENT; HEART CATHETERIZATION; HEART HEMODYNAMICS; HEART LEFT VENTRICLE FUNCTION; HEART VALVE SURGERY; HUMAN; PRESSURE VOLUME CURVE; TRANSDUCER; TRANSLUMINAL VALVULOPLASTY; WAVEFORM;

EID: 0033999161     PISSN: 01679899     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1006349123217     Document Type: Article
Times cited : (3)

References (9)
  • 2
    • 0023796309 scopus 로고
    • Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man
    • Kass DA, Midei M, Graves W, Brinker JA, Maughan WL. Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man. Cath Cardiovasc Diagn 1988; 15: 192-202.
    • (1988) Cath Cardiovasc Diagn , vol.15 , pp. 192-202
    • Kass, D.A.1    Midei, M.2    Graves, W.3    Brinker, J.A.4    Maughan, W.L.5
  • 4
    • 0021854779 scopus 로고
    • Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts
    • Burkhoff D, Van Der Velde ET, Kass D, Baan J, Maughan WL, Sagawa K. Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts. Circulation 1985; 72: 440-447.
    • (1985) Circulation , vol.72 , pp. 440-447
    • Burkhoff, D.1    Van Der Velde, E.T.2    Kass, D.3    Baan, J.4    Maughan, W.L.5    Sagawa, K.6
  • 5
    • 0025020618 scopus 로고
    • Simultaneous conductance catheter and dimension assessment of left ventricle volume in the intact animal
    • Applegate RJ, Cheng CP, Little WC. Simultaneous conductance catheter and dimension assessment of left ventricle volume in the intact animal. Circulation 1990; 81: 638-648.
    • (1990) Circulation , vol.81 , pp. 638-648
    • Applegate, R.J.1    Cheng, C.P.2    Little, W.C.3
  • 6
    • 0025062577 scopus 로고
    • The conductance method of left ventricular volume estimation. Methodological limitations put into perspective
    • Burkhoff D. The conductance method of left ventricular volume estimation. Methodological limitations put into perspective (editorial comment). Circulation 1990; 81: 703-706.
    • (1990) Circulation , vol.81 , pp. 703-706
    • Burkhoff, D.1
  • 7
    • 0029874060 scopus 로고    scopus 로고
    • Automated determination of left ventricular volume curves from bi-plane digital angiography without explicit use of edge detection algorithms
    • Raff U, Vargas PF, Groves BM. Automated determination of left ventricular volume curves from bi-plane digital angiography without explicit use of edge detection algorithms. Int J Cardiac Imaging 1996; 12: 31-45.
    • (1996) Int J Cardiac Imaging , vol.12 , pp. 31-45
    • Raff, U.1    Vargas, P.F.2    Groves, B.M.3
  • 8
    • 0000713480 scopus 로고
    • The use of biplane angiocardiography for the measurement of left ventricular volume in man
    • Dodge HT, Sandler H, Ballew DW, Lord JD Jr. The use of biplane angiocardiography for the measurement of left ventricular volume in man. Am Heart J 1960; 60: 762-776.
    • (1960) Am Heart J , vol.60 , pp. 762-776
    • Dodge, H.T.1    Sandler, H.2    Ballew, D.W.3    Lord J.D., Jr.4
  • 9
    • 84886625118 scopus 로고
    • Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections
    • Wynne J, Green LH, Mann T, Levin D, Grossman W. Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections. Am J Cardiol 1978; 41: 726-732.
    • (1978) Am J Cardiol , vol.41 , pp. 726-732
    • Wynne, J.1    Green, L.H.2    Mann, T.3    Levin, D.4    Grossman, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.