1
-
-
0023422081
-
Representative sampling of ground water from short screened boreholes
-
Barber, C., and G.B. Davis. 1987. Representative sampling of ground water from short screened boreholes. Ground Water 25, no. 5: 581-587.
-
(1987)
Ground Water
, vol.25
, Issue.5
, pp. 581-587
-
-
Barber, C.1
Davis, G.B.2
-
2
-
-
85034001552
-
Sample program purpose and design considerations
-
December 2, at Dallas, Texas
-
Barcelona, M.J. 1993. Sample program purpose and design considerations. Paper read at Ground Water Sampling - A Workshop Summary, December 2, at Dallas, Texas.
-
(1993)
Ground Water Sampling - A Workshop Summary
-
-
Barcelona, M.J.1
-
3
-
-
0028093904
-
Reproducible well-purging procedures and VOC stabilization criteria for ground water sampling
-
Barcelona, M.J., H.A. Wehrmann, and M.D. Varljen. 1994. Reproducible well-purging procedures and VOC stabilization criteria for ground water sampling. Ground Water 32, no. 1: 12-22.
-
(1994)
Ground Water
, vol.32
, Issue.1
, pp. 12-22
-
-
Barcelona, M.J.1
Wehrmann, H.A.2
Varljen, M.D.3
-
4
-
-
84980300582
-
The relationship between monitoring well and aquifer solute concentrations
-
Chiang, C., C. Dawson, and G. Raven. 1995. The relationship between monitoring well and aquifer solute concentrations. Ground Water 33, no. 5: 718-726.
-
(1995)
Ground Water
, vol.33
, Issue.5
, pp. 718-726
-
-
Chiang, C.1
Dawson, C.2
Raven, G.3
-
5
-
-
0030106368
-
Bias in ground water data caused by well-bore flow in long screen wells
-
Church, P.E., and G.E. Granato. 1996. Bias in ground water data caused by well-bore flow in long screen wells. Ground Water 34, no. 2: 262-273.
-
(1996)
Ground Water
, vol.34
, Issue.2
, pp. 262-273
-
-
Church, P.E.1
Granato, G.E.2
-
6
-
-
84980279865
-
Simulation of sampling and hydraulic tests to assess a hybrid monitoring well design
-
Cohen, R.M., and R.R. Rabold. 1988. Simulation of sampling and hydraulic tests to assess a hybrid monitoring well design. Ground Water Monitoring Review 8, no. 1: 51-59.
-
(1988)
Ground Water Monitoring Review
, vol.8
, Issue.1
, pp. 51-59
-
-
Cohen, R.M.1
Rabold, R.R.2
-
7
-
-
0027555215
-
Effects of small-scale vertical variations in well-screen inflow rates and concentrations of organic compounds on the collection of representative ground water quality samples
-
Gibs, J., G.A. Brown, K.S. Turner, C.L. MacLeod, J.C. Jelinski, and S.A. Koehnlein. 1993. Effects of small-scale vertical variations in well-screen inflow rates and concentrations of organic compounds on the collection of representative ground water quality samples. Ground Water 31, no. 2: 201-208.
-
(1993)
Ground Water
, vol.31
, Issue.2
, pp. 201-208
-
-
Gibs, J.1
Brown, G.A.2
Turner, K.S.3
MacLeod, C.L.4
Jelinski, J.C.5
Koehnlein, S.A.6
-
8
-
-
0023524246
-
Monitoring well installation, purging, and sampling techniques - Part 1: Conceptualizations
-
Keely, J.F., and K. Boateng. 1987. Monitoring well installation, purging, and sampling techniques - Part 1: Conceptualizations. Ground Water 25, no. 3: 300-313.
-
(1987)
Ground Water
, vol.25
, Issue.3
, pp. 300-313
-
-
Keely, J.F.1
Boateng, K.2
-
10
-
-
0031105337
-
Plume distortion and apparent attenuation due to concentration averaging in monitoring wells
-
Martin-Hayden, J.M., and G.A. Robbins. 1997. Plume distortion and apparent attenuation due to concentration averaging in monitoring wells. Ground Water 35, no. 2: 339-346.
-
(1997)
Ground Water
, vol.35
, Issue.2
, pp. 339-346
-
-
Martin-Hayden, J.M.1
Robbins, G.A.2
-
11
-
-
0026359366
-
Mass balance evaluation of monitoring well purging. Part II: Field tests at a gasoline contamination site
-
Martin-Hayden, J.M., G.A. Robbins, and R.D. Bristol. 1991. Mass balance evaluation of monitoring well purging. Part II: Field tests at a gasoline contamination site. Journal of Contaminant Hydrology 8, no. 3/4: 225-241.
-
(1991)
Journal of Contaminant Hydrology
, vol.8
, Issue.3-4
, pp. 225-241
-
-
Martin-Hayden, J.M.1
Robbins, G.A.2
Bristol, R.D.3
-
12
-
-
85038058826
-
Detailed investigations of monitoring well borehole flow and mixing resulting in artificial groundwater data variability
-
April 29
-
Martin-Hayden, J.M., and N.B. Zieske. 1997. Detailed investigations of monitoring well borehole flow and mixing resulting in artificial groundwater data variability. Paper read at Eos, Transactions, American Geophysical Union 1997 Spring Meeting, April 29.
-
(1997)
Eos, Transactions, American Geophysical Union 1997 Spring Meeting
-
-
Martin-Hayden, J.M.1
Zieske, N.B.2
-
13
-
-
0027545384
-
Passive sampling of groundwater monitoring wells without purging: Multilevel well chemistry and tracer disappearance
-
Powell, R.M., and R.W. Puls. 1993. Passive sampling of groundwater monitoring wells without purging: Multilevel well chemistry and tracer disappearance. Journal of Contaminant Hydrology 12, no. 1/2: 51-77.
-
(1993)
Journal of Contaminant Hydrology
, vol.12
, Issue.1-2
, pp. 51-77
-
-
Powell, R.M.1
Puls, R.W.2
-
15
-
-
0024607856
-
Bias in groundwater samples caused by wellbore flow
-
Reilly, T.E., O.L. Frank, and G.D. Bennet. 1989. Bias in groundwater samples caused by wellbore flow. ASCE, Journal of Hydraulic Engineering 115: 270-276.
-
(1989)
ASCE, Journal of Hydraulic Engineering
, vol.115
, pp. 270-276
-
-
Reilly, T.E.1
Frank, O.L.2
Bennet, G.D.3
-
16
-
-
0027657382
-
Effects of physical and chemical heterogeneity on water-quality samples obtained from wells
-
Reilly, T.E., and J. Gibs. 1993. Effects of physical and chemical heterogeneity on water-quality samples obtained from wells. Ground Water 31, no. 5: 805-813.
-
(1993)
Ground Water
, vol.31
, Issue.5
, pp. 805-813
-
-
Reilly, T.E.1
Gibs, J.2
-
17
-
-
0032128363
-
Experimental evaluation of factors affecting temporal variability of water samples obtained from long-screen wells
-
Reilly, T.E., and D.R. LeBlanc. 1998. Experimental evaluation of factors affecting temporal variability of water samples obtained from long-screen wells. Ground Water 36, no. 4: 566-576.
-
(1998)
Ground Water
, vol.36
, Issue.4
, pp. 566-576
-
-
Reilly, T.E.1
LeBlanc, D.R.2
-
18
-
-
0024476460
-
Influence of using purged and partially penetrating monitoring wells on contaminant detection, mapping and modeling
-
Robbins, G.A. 1989. Influence of using purged and partially penetrating monitoring wells on contaminant detection, mapping and modeling. Ground Water 27, no. 2: 155-162.
-
(1989)
Ground Water
, vol.27
, Issue.2
, pp. 155-162
-
-
Robbins, G.A.1
-
19
-
-
0026359365
-
Mass balance evaluation of monitoring well purging. Part I: Theoretical models and implications for representative sampling
-
Robbins, G.A., and J.M. Martin-Hayden. 1991. Mass balance evaluation of monitoring well purging. Part I: Theoretical models and implications for representative sampling. Journal of Contaminant Hydrology 8, no. 3/4: 203-224.
-
(1991)
Journal of Contaminant Hydrology
, vol.8
, Issue.3-4
, pp. 203-224
-
-
Robbins, G.A.1
Martin-Hayden, J.M.2
-
20
-
-
0026108865
-
Importance of closely spaced vertical sampling in delineating chemical and microbial gradients in groundwater studies
-
Smith, R.L., R.W. Harvey, and D.R. LeBlanc. 1991. Importance of closely spaced vertical sampling in delineating chemical and microbial gradients in groundwater studies. Journal of Contaminant Hydrology 7: 285-300.
-
(1991)
Journal of Contaminant Hydrology
, vol.7
, pp. 285-300
-
-
Smith, R.L.1
Harvey, R.W.2
LeBlanc, D.R.3
|