메뉴 건너뛰기




Volumn 26, Issue 1, 2000, Pages 63-71

High-frequency color flow imaging of the microcirculation

Author keywords

Angiogenesis; Blood flow; Blood velocity; Color Doppler imaging; Color flow mapping; Doppler ultrasound; High frequency ultrasound; Microcirculation; Microvascular morphology

Indexed keywords

COLOR IMAGE PROCESSING; DOPPLER EFFECT; MEDICAL IMAGING; MICROCIRCULATION; MORPHOLOGY; OPTICAL RESOLVING POWER; ULTRASONIC TRANSDUCERS;

EID: 0033983896     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00101-5     Document Type: Article
Times cited : (93)

References (31)
  • 2
    • 0014884119 scopus 로고
    • Thickness, cross-sectional areas, and depth of invasion in the prognosis of cutaneous melanoma
    • Breslow A. Thickness, cross-sectional areas, and depth of invasion in the prognosis of cutaneous melanoma. Ann Surg. 172:1970;902-908.
    • (1970) Ann Surg , vol.172 , pp. 902-908
    • Breslow, A.1
  • 3
    • 0026829847 scopus 로고
    • Initialization for improved IIR filter performance
    • Chornoby S. Initialization for improved IIR filter performance. IEEE Trans Signal Processing. 40:1992;543-550.
    • (1992) IEEE Trans Signal Processing , vol.40 , pp. 543-550
    • Chornoby, S.1
  • 5
    • 0030931135 scopus 로고    scopus 로고
    • A high frequency pulsed-wave Doppler ultrasound system for the detection of blood flow in the microcirculation
    • Christopher D.A., Burns P.N., Starkoski B.G., Foster F.S. A high frequency pulsed-wave Doppler ultrasound system for the detection of blood flow in the microcirculation. Ultrasound Med Biol. 23:1997;997-1015.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 997-1015
    • Christopher, D.A.1    Burns, P.N.2    Starkoski, B.G.3    Foster, F.S.4
  • 7
    • 0004228932 scopus 로고
    • Ph.D.Thesis, Erasmus University, Rotterdam, The Netherlands
    • de Kroon M. Acoustic backscatter in arteries. Ph.D.Thesis, Erasmus University, Rotterdam, The Netherlands, 1993.
    • (1993) Acoustic Backscatter in Arteries
    • De Kroon, M.1
  • 8
    • 0026077013 scopus 로고
    • A new wideband spread target maximum likelihood estimator for blood velocity estimation, Part I: The theory
    • Ferrara K., Algazi V.R. A new wideband spread target maximum likelihood estimator for blood velocity estimation, Part I The theory . IEEE Trans Ultrason Ferroelec Freq Contr. 38:1991;1-16.
    • (1991) IEEE Trans Ultrason Ferroelec Freq Contr , vol.38 , pp. 1-16
    • Ferrara, K.1    Algazi, V.R.2
  • 12
    • 0023909330 scopus 로고
    • Determinants of tumor blood flow: A review
    • Jain R.K. Determinants of tumor blood flow A review . Cancer Res. 48:1988;2641-2658.
    • (1988) Cancer Res , vol.48 , pp. 2641-2658
    • Jain, R.K.1
  • 13
    • 0030669894 scopus 로고    scopus 로고
    • Quantitative angiogenesis assays: Progress and problems
    • Jain R.K., Schlenger K., Hockel M., Yuan F. Quantitative angiogenesis assays Progress and problems . Nature Med. 3:1997;1203-1208.
    • (1997) Nature Med , vol.3 , pp. 1203-1208
    • Jain, R.K.1    Schlenger, K.2    Hockel, M.3    Yuan, F.4
  • 15
    • 0029378406 scopus 로고
    • On the performance of regression and step-initialized IIR clutter filters for color Doppler systems in diagnostic medical ultrasound
    • Kadi A.R., Loupas T. On the performance of regression and step-initialized IIR clutter filters for color Doppler systems in diagnostic medical ultrasound. IEEE Trans Ultrason Ferroelec Freq Contr. 42:1995;927-937.
    • (1995) IEEE Trans Ultrason Ferroelec Freq Contr , vol.42 , pp. 927-937
    • Kadi, A.R.1    Loupas, T.2
  • 18
    • 0028397298 scopus 로고
    • Fabrication and characterization of high frequency (40-100 MHz) spherically shaped ceramic transducers
    • Lockwood G.R., Foster F.S. Fabrication and characterization of high frequency (40-100 MHz) spherically shaped ceramic transducers. IEEE Trans Ultrason Ferroelec Freq Contr. 41:1994;225-230.
    • (1994) IEEE Trans Ultrason Ferroelec Freq Contr , vol.41 , pp. 225-230
    • Lockwood, G.R.1    Foster, F.S.2
  • 19
    • 0026066451 scopus 로고
    • Measurement of the ultrasonic properties of vascular tissue and blood from 35 to 65 MHz
    • Lockwood G.R., Ryan L.K., Hunt J.W., Foster F.S. Measurement of the ultrasonic properties of vascular tissue and blood from 35 to 65 MHz. Ultrasound Med Biol. 17:1991;653-666.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 653-666
    • Lockwood, G.R.1    Ryan, L.K.2    Hunt, J.W.3    Foster, F.S.4
  • 20
    • 0029344303 scopus 로고
    • Experimental evaluation of velocity and power estimation for ultrasound blood flow imaging by means of a two-dimensional autocorrelation approach
    • Loupas T., Peterson R.B., Gill R.W. Experimental evaluation of velocity and power estimation for ultrasound blood flow imaging by means of a two-dimensional autocorrelation approach. IEEE Trans Ultrason Ferroelec Freq Contr. 42:1995;689-699.
    • (1995) IEEE Trans Ultrason Ferroelec Freq Contr , vol.42 , pp. 689-699
    • Loupas, T.1    Peterson, R.B.2    Gill, R.W.3
  • 21
    • 0029344834 scopus 로고
    • An axial velocity estimator for ultrasound blood flow imaging based on a full evaluation of the Doppler equation using a 2-dimensional autocorrelation approach
    • Loupas T., Powers J.E., Gill R.W. An axial velocity estimator for ultrasound blood flow imaging based on a full evaluation of the Doppler equation using a 2-dimensional autocorrelation approach. IEEE Trans Ultrason Ferroelec Freq Contr. 42:1995;672-688.
    • (1995) IEEE Trans Ultrason Ferroelec Freq Contr , vol.42 , pp. 672-688
    • Loupas, T.1    Powers, J.E.2    Gill, R.W.3
  • 22
    • 0026525544 scopus 로고
    • Skin capillary metrics and hemodynamics in the hairless mouse
    • Mayrovitz H.N. Skin capillary metrics and hemodynamics in the hairless mouse. Microvasc Res. 43:1992;46-59.
    • (1992) Microvasc Res , vol.43 , pp. 46-59
    • Mayrovitz, H.N.1
  • 23
    • 0000649462 scopus 로고    scopus 로고
    • Imaging instrumentation for ultrasound contrast agents
    • In: Nanda NC, Reinhard S, Goldberg BB, eds. Dordrecht, The Netherlands: Kluwer Academic Press
    • Powers JE, Burns PN, Souquet J. Imaging instrumentation for ultrasound contrast agents. In: Nanda NC, Reinhard S, Goldberg BB, eds. Advances in echo imaging using contrast enhancement. Dordrecht, The Netherlands: Kluwer Academic Press, 1997.
    • (1997) Advances in Echo Imaging Using Contrast Enhancement
    • Powers, J.E.1    Burns, P.N.2    Souquet, J.3
  • 24
    • 0028273083 scopus 로고
    • Power Doppler US: A potentially useful alternative to mean frequency based color Doppler
    • Rubin J.M., Bude R.O., Carson P.L., Bree R.L., Adler R.S. Power Doppler US A potentially useful alternative to mean frequency based color Doppler . Radiology. 190:1994;853-856.
    • (1994) Radiology , vol.190 , pp. 853-856
    • Rubin, J.M.1    Bude, R.O.2    Carson, P.L.3    Bree, R.L.4    Adler, R.S.5
  • 25
    • 0024394809 scopus 로고
    • The design and fabrication of high frequency poly (vinylidene flouride) transducers
    • Sherar M.D., Foster F.S. The design and fabrication of high frequency poly (vinylidene flouride) transducers. Ultrason Imaging. 11:1989;75-94.
    • (1989) Ultrason Imaging , vol.11 , pp. 75-94
    • Sherar, M.D.1    Foster, F.S.2
  • 29
    • 0031349076 scopus 로고    scopus 로고
    • Application of high frequency broadband ultrasound for high resolution blood flow measurement
    • Vogt M., Ermert H. Application of high frequency broadband ultrasound for high resolution blood flow measurement. Proc IEEE Ultrason Symp. 2:1997;1243-1246.
    • (1997) Proc IEEE Ultrason Symp , vol.2 , pp. 1243-1246
    • Vogt, M.1    Ermert, H.2
  • 30
    • 0026083903 scopus 로고
    • Tumor angiogenesis and metastasis - correlation with invasive breast carcinoma
    • Weidner N., Semple J.P., Welch W.R., Folkman J. Tumor angiogenesis and metastasis - correlation with invasive breast carcinoma. N Engl J Med. 106:1991;1-8.
    • (1991) N Engl J Med , vol.106 , pp. 1-8
    • Weidner, N.1    Semple, J.P.2    Welch, W.R.3    Folkman, J.4
  • 31
    • 84944296578 scopus 로고
    • Ultrasound characterization of ocular tissue in the frequency range from 50 MHz to 100 MHz
    • Ye S.G., Harasiewicz K.A., Pavlin C.J., Foster F.S. Ultrasound characterization of ocular tissue in the frequency range from 50 MHz to 100 MHz. Proc IEEE Ultrason Symp. 2:1992;1107-1112.
    • (1992) Proc IEEE Ultrason Symp , vol.2 , pp. 1107-1112
    • Ye, S.G.1    Harasiewicz, K.A.2    Pavlin, C.J.3    Foster, F.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.