-
1
-
-
0031929179
-
Fluid pressure may cause periprosthetic osteolysis. Particles are not the only thing
-
ASPENBERG P, VAN DER VIS H : Fluid pressure may cause periprosthetic osteolysis. Particles are not the only thing. Acta Orthop Scand, 1998, 69, 1-4.
-
(1998)
Acta Orthop Scand
, vol.69
, pp. 1-4
-
-
Aspenberg, P.1
Van Der Vis, H.2
-
2
-
-
0027208262
-
Extensive osteolysis around an aseptic stable Total Knee Replacement
-
BERRY DJ, WOLD LE, RAND JA : Extensive osteolysis around an aseptic stable Total Knee Replacement. Clin Orthop, 1993, 293, 204-207.
-
(1993)
Clin Orthop
, vol.293
, pp. 204-207
-
-
Berry, D.J.1
Wold, L.E.2
Rand, J.A.3
-
3
-
-
0028580091
-
Osteolysis of the distal femur after Total Knee Arthroplasty
-
CADAMBI A, ENGH GA, VINH TN : Osteolysis of the distal femur after Total Knee Arthroplasty. J Arthropl, 1994,6, 574-579.
-
(1994)
J Arthropl
, vol.6
, pp. 574-579
-
-
Cadambi, A.1
Engh, G.A.2
Vinh, T.N.3
-
4
-
-
0342442823
-
Different messenger ribonucleic acid expression in agressive versus periprosthetic lysis
-
CHANG Y, JIRANEK WA, VAUGHAN P, CARDEA JA : Different messenger ribonucleic acid expression in agressive versus periprosthetic lysis. Clin Orthop, 1998, 352, 95-104.
-
(1998)
Clin Orthop
, vol.352
, pp. 95-104
-
-
Chang, Y.1
Jiranek, W.A.2
Vaughan, P.3
Cardea, J.A.4
-
5
-
-
0028039066
-
A biochemical, histologic and immunohistochemical analysis of membranes obtained from failed cemented and uncemented total knee arthroplasty
-
CHIBA J, SCHWENDEMAN LE, BOOTH RE, CROSSET LS, RUBASH HE : A biochemical, histologic and immunohistochemical analysis of membranes obtained from failed cemented and uncemented total knee arthroplasty. Clin Orthop, 1994, 299, 114-124.
-
(1994)
Clin Orthop
, vol.299
, pp. 114-124
-
-
Chiba, J.1
Schwendeman, L.E.2
Booth, R.E.3
Crosset, L.S.4
Rubash, H.E.5
-
6
-
-
0028825118
-
The posterior stabilized total knee prosthesis. Assesment of polyethylene damage and osteolysis after a ten year minimum follow-up
-
COLIZZA WA, INSALL JN, SCUDERI GR : The posterior stabilized total knee prosthesis. Assesment of polyethylene damage and osteolysis after a ten year minimum follow-up. J Bone Joint Surg, 1995,77 A, 1713-1720.
-
(1995)
J Bone Joint Surg
, vol.77 A
, pp. 1713-1720
-
-
Colizza, W.A.1
Insall, J.N.2
Scuderi, G.R.3
-
7
-
-
0026773329
-
Corrosion between components of modular femoral hip prosthesis
-
COLLIER JP, SURPRENANT VA, JENSEN RE, MAYO MB, SURPRENANT HP : Corrosion between components of modular femoral hip prosthesis. J Bone Joint Surg, 1992, 74B, 511-517.
-
(1992)
J Bone Joint Surg
, vol.74 B
, pp. 511-517
-
-
Collier, J.P.1
Surprenant, V.A.2
Jensen, R.E.3
Mayo, M.B.4
Surprenant, H.P.5
-
8
-
-
0024058346
-
Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report
-
ENGH CH : Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report J Bone Joint Surg, 1988, 70 A, 1093-1096.
-
(1988)
J Bone Joint Surg
, vol.70 A
, pp. 1093-1096
-
-
Engh, C.H.1
-
9
-
-
0026527293
-
Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
-
ENGH GA, DWYER KA, HANES CK : Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg, 1992, 74 B, 9-17.
-
(1992)
J Bone Joint Surg
, vol.74 B
, pp. 9-17
-
-
Engh, G.A.1
Dwyer, K.A.2
Hanes, C.K.3
-
10
-
-
0024950156
-
The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system
-
EWALD FC : The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop, 1989, 248, 9-12.
-
(1989)
Clin Orthop
, vol.248
, pp. 9-12
-
-
Ewald, F.C.1
-
11
-
-
0028849719
-
Effect of component fixation method on osteolysis in TKA
-
EZZET KA, GARCIA R, BARRACK RL : Effect of component fixation method on osteolysis in TKA. Clin Orthop, 1995, 321, 86-91.
-
(1995)
Clin Orthop
, vol.321
, pp. 86-91
-
-
Ezzet, K.A.1
Garcia, R.2
Barrack, R.L.3
-
12
-
-
0032388708
-
Phosphatase acide tartrate résistante (TRAP) et cytologie des membranes pseudo-synoviales
-
FRAYSSINET P, GINESTE L, PRIMOUT I, GUILHEM A : Phosphatase acide tartrate résistante (TRAP) et cytologie des membranes pseudo-synoviales. Bul Assoc Anat, 1998, 82, 256, 9-11.
-
(1998)
Bul Assoc Anat
, vol.82
, Issue.256
, pp. 9-11
-
-
Frayssinet, P.1
Gineste, L.2
Primout, I.3
Guilhem, A.4
-
13
-
-
0017129995
-
Extensive localized bone resorption in the femur following total hip replacement
-
HARRIS WH, SCHILLER AL, SCHOLLER JM, FREIBERG RA, SCOTT R : Extensive localized bone resorption in the femur following total hip replacement. J Bone Joint Surg, 1976, 58A, 612-618.
-
(1976)
J Bone Joint Surg
, vol.58 A
, pp. 612-618
-
-
Harris, W.H.1
Schiller, A.L.2
Scholler, J.M.3
Freiberg, R.A.4
Scott, R.5
-
14
-
-
0029973991
-
Characterisation of debris adjacent to failed knee implants of 3 different designs
-
HIRAKAWA K, BAUER TW, STULBERG BN, WILDE AH, BORDENL LS : Characterisation of debris adjacent to failed knee implants of 3 different designs. Clin Orthop, 1996, 331, 151-158.
-
(1996)
Clin Orthop
, vol.331
, pp. 151-158
-
-
Hirakawa, K.1
Bauer, T.W.2
Stulberg, B.N.3
Wilde, A.H.4
Bordenl, L.S.5
-
15
-
-
0028587748
-
Comparison of interface membranes obtained from failed cemented and cementless hip and knee protheses
-
HORIKOSHI M, MACAULAY W, BOOTH RE, CROSSETT LS, RUBASH HE : Comparison of interface membranes obtained from failed cemented and cementless hip and knee protheses. Clin Orthop, 1994, 309, 69-87.
-
(1994)
Clin Orthop
, vol.309
, pp. 69-87
-
-
Horikoshi, M.1
Macaulay, W.2
Booth, R.E.3
Crossett, L.S.4
Rubash, H.E.5
-
16
-
-
0027260321
-
Studies of the mechanism which the mechanical failure of PPMA leads to bone resorption
-
HOROWITZ SM, DOTY SB, LANE JM, BURSTEIN AH : Studies of the mechanism which the mechanical failure of PPMA leads to bone resorption. J Bone Joint Surg, 1993 75A, 802-813.
-
(1993)
J Bone Joint Surg
, vol.75 A
, pp. 802-813
-
-
Horowitz, S.M.1
Doty, S.B.2
Lane, J.M.3
Burstein, A.H.4
-
17
-
-
0031938258
-
Wear and osteolysis in total joint replacement
-
KADOYA Y, KOBAYASHI A, OHASHI H : Wear and osteolysis in total joint replacement. Acta Orthop Scand, 1998, 69, 4-16.
-
(1998)
Acta Orthop Scand
, vol.69
, pp. 4-16
-
-
Kadoya, Y.1
Kobayashi, A.2
Ohashi, H.3
-
18
-
-
0028923420
-
Osteolysis around cementless porous coated anatomic knee prostheses
-
KIM YH, OH JH, OH SH : Osteolysis around cementless porous coated anatomic knee prostheses. J Bone Joint Surg, 1995, 77B, 236-241.
-
(1995)
J Bone Joint Surg
, vol.77 B
, pp. 236-241
-
-
Kim, Y.H.1
Oh, J.H.2
Oh, S.H.3
-
19
-
-
0028842839
-
Screw osteolysis after cementless total knee replacement
-
LEWIS PL, RORABECK CH, BOURNE RB : Screw osteolysis after cementless total knee replacement. Clin Orthop, 1995, 321, 173-177.
-
(1995)
Clin Orthop
, vol.321
, pp. 173-177
-
-
Lewis, P.L.1
Rorabeck, C.H.2
Bourne, R.B.3
-
20
-
-
0028057541
-
Wear debris an environmental issue in total joints replacement
-
MANLEY MT, SEREKIAN MS : Wear debris an environmental issue in total joints replacement. Clin Orthop, 1994, 298, 137-146.
-
(1994)
Clin Orthop
, vol.298
, pp. 137-146
-
-
Manley, M.T.1
Serekian, M.S.2
-
21
-
-
0029120016
-
Periprosthetic osteolysis in total hip athroplasty : The role of particulate wear debris
-
MALONEY WJ, SMITH RL : Periprosthetic osteolysis in total hip athroplasty : the role of particulate wear debris. J Bone Joint Surg, 1995, 77A, 1448-1461.
-
(1995)
J Bone Joint Surg
, vol.77 A
, pp. 1448-1461
-
-
Maloney, W.J.1
Smith, R.L.2
-
22
-
-
85062112917
-
Osteolysis after TKA review of 25 cases treated with and without tibial component revision
-
PETERS PC, ENGH GH, KIMBERLY AD, VINH TN : Osteolysis after TKA review of 25 cases treated with and without tibial component revision. Clin Orthop, 1994, 309, 33-43.
-
(1994)
Clin Orthop
, vol.309
, pp. 33-43
-
-
Peters, P.C.1
Engh, G.H.2
Kimberly, A.D.3
Vinh, T.N.4
-
23
-
-
0026784175
-
Osteolysis after total knee arthroplasty without cement
-
PETERS PC, ENGH GH, DWYER KA, VINH TN : Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg, 1992, 74 A, 864-876.
-
(1992)
J Bone Joint Surg
, vol.74 A
, pp. 864-876
-
-
Peters, P.C.1
Engh, G.H.2
Dwyer, K.A.3
Vinh, T.N.4
-
24
-
-
0026328948
-
Cement or cementless fixation in total knee replacement
-
RAND JA : Cement or cementless fixation in total knee replacement. Clin Orthop, 1991 273, 52-62.
-
(1991)
Clin Orthop
, vol.273
, pp. 52-62
-
-
Rand, J.A.1
-
25
-
-
0028785801
-
Catastrophic Osteolysis in total knee arthroplasty
-
ROBINSON EJ, BOURNE RB, RORABECK CH : Catastrophic Osteolysis in total knee arthroplasty. Clin Orthop, 1995, 321, 98-105.
-
(1995)
Clin Orthop
, vol.321
, pp. 98-105
-
-
Robinson, E.J.1
Bourne, R.B.2
Rorabeck, C.H.3
-
26
-
-
0028832556
-
Effect of porous-coating configuration on tibial osteolysis after TKA
-
WHITESIDE LA : Effect of porous-coating configuration on tibial osteolysis after TKA. Clin Orthop, 1995, 321, 92-97.
-
(1995)
Clin Orthop
, vol.321
, pp. 92-97
-
-
Whiteside, L.A.1
-
27
-
-
0017462028
-
Reactions of the articular capsule to wear products of artificial joint prostheses
-
WILLERT HG : Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res, 1977, 11, 157-164.
-
(1977)
J Biomed Mater Res
, vol.11
, pp. 157-164
-
-
Willert, H.G.1
-
28
-
-
0016251286
-
Reaction of bone to methacrylate after hip arthroplasty. A long-term gross, light microscopic, and scanning electron microscopic study
-
WILLERT HG, LUDWIG J, SEMTLITSCH M : Reaction of bone to methacrylate after hip arthroplasty. A long-term gross, light microscopic, and scanning electron microscopic study. J Bone Joint Surg, 1974, 56 A, 1368-1382.
-
(1974)
J Bone Joint Surg
, vol.56 A
, pp. 1368-1382
-
-
Willert, H.G.1
Ludwig, J.2
Semtlitsch, M.3
|