Volumn 15, Issue 1, 2000, Pages 93-101

The anatomic basis for the concept of lateralized femoral stems: A frontal plane radiographic study of the proximal femur

Author keywords

Femoral anatomy; Femoral stem design; Total hip replacement

Indexed keywords

ADULT; AGED; ARTICLE; FEMALE; FEMUR; FEMUR SHAFT; HUMAN; MAJOR CLINICAL STUDY; MALE; METAPHYSIS; OSTEOARTHRITIS; OSTEOTOMY; PELVIS RADIOGRAPHY; TOTAL HIP PROSTHESIS;

EID: 0033971473     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(00)91337-8     Document Type: Article
Times cited : (94)

References (25)
  • 1
    • 0026771982 scopus 로고
    • Failure of cementless fixation of the femoral component in total hip arthroplasty
    • Otani T, Whiteside L: Failure of cementless fixation of the femoral component in total hip arthroplasty. Orthop Clin North Am 23:335, 1992
    • (1992) Orthop Clin North Am , vol.23 , pp. 335
    • Otani, T.1    Whiteside, L.2
  • 2
    • 0023759917 scopus 로고
    • Design and fabrication of cementless hip stems
    • Walker PS, Robertson DD: Design and fabrication of cementless hip stems. Clin Orthop 235:25, 1988
    • (1988) Clin Orthop , vol.235 , pp. 25
    • Walker, P.S.1    Robertson, D.D.2
  • 3
    • 0023161998 scopus 로고
    • Strains and micromotions of pressfit femoral stem prosthesis
    • Walker PS, Schneeweis D, Murphy S: Strains and micromotions of pressfit femoral stem prosthesis. J Biomech 20:693, 1987
    • (1987) J Biomech , vol.20 , pp. 693
    • Walker, P.S.1    Schneeweis, D.2    Murphy, S.3
  • 4
    • 0024951004 scopus 로고
    • Cementless total hip arthroplasty using the anatomic medullary locking stem: Results using a survivorship analysis
    • Engh CA, Massin P: Cementless total hip arthroplasty using the anatomic medullary locking stem: results using a survivorship analysis. Clin Orthop 249:141, 1989
    • (1989) Clin Orthop , vol.249 , pp. 141
    • Engh, C.A.1    Massin, P.2
  • 5
    • 0028344842 scopus 로고
    • Relative motion of hip stems under load: An in vitro study of symmetrical, asymmetrical and custom asymmetrical designs
    • Hua J, Walker PS: Relative motion of hip stems under load: an in vitro study of symmetrical, asymmetrical and custom asymmetrical designs. J Bone Joint Surg Am 76:95, 1994
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 95
    • Hua, J.1    Walker, P.S.2
  • 6
    • 0024591258 scopus 로고
    • Torsional stability of the femoral component of hip arthroplasty: Response to an anteriorly applied load
    • Nunn D, Freeman MA, Tanner KE, et al: Torsional stability of the femoral component of hip arthroplasty: response to an anteriorly applied load. J Bone Joint Surg Br 71:452, 1989
    • (1989) J Bone Joint Surg Br , vol.71 , pp. 452
    • Nunn, D.1    Freeman, M.A.2    Tanner, K.E.3
  • 7
    • 0027405949 scopus 로고
    • Torsional fixation of a modular femoral hip component
    • Ohl MD, Whiteside LA, McCarthy DS, et al: Torsional fixation of a modular femoral hip component. Clin Orthop 287:135, 1993
    • (1993) Clin Orthop , vol.287 , pp. 135
    • Ohl, M.D.1    Whiteside, L.A.2    McCarthy, D.S.3
  • 8
    • 0025285358 scopus 로고
    • Femoral stem fixation in hip replacement: A biomechanical comparison of cementless and cemented prostheses
    • Phillips TW, Messieh SS, McDonald PD: Femoral stem fixation in hip replacement: a biomechanical comparison of cementless and cemented prostheses. J Bone Joint Surg Br 72:431, 1990
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 431
    • Phillips, T.W.1    Messieh, S.S.2    McDonald, P.D.3
  • 9
    • 0026602161 scopus 로고
    • Torsional fixation of the femoral component in total hip arthroplasty
    • Sugiyama H, Whiteside LA, Engh CA: Torsional fixation of the femoral component in total hip arthroplasty. Clin Orthop 275:187, 1992
    • (1992) Clin Orthop , vol.275 , pp. 187
    • Sugiyama, H.1    Whiteside, L.A.2    Engh, C.A.3
  • 10
    • 0024957650 scopus 로고
    • Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission
    • Sugiyama H, Whiteside LA, Kaiser AD: Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission. Clin Orthop 249:122, 1989
    • (1989) Clin Orthop , vol.249 , pp. 122
    • Sugiyama, H.1    Whiteside, L.A.2    Kaiser, A.D.3
  • 11
    • 0027712397 scopus 로고
    • Etude anatomique et extensométrique concernant la collerette d'appui et le manche de la prothèse, base de la conception d'une prothèse anatomique
    • Blaimont P, Delronge B, Smeyers B, et al: Etude anatomique et extensométrique concernant la collerette d'appui et le manche de la prothèse, base de la conception d'une prothèse anatomique. Acta Orthop Belg 59 (suppl 1):170, 1993
    • (1993) Acta Orthop Belg , vol.59 , Issue.1 SUPPL. , pp. 170
    • Blaimont, P.1    Delronge, B.2    Smeyers, B.3
  • 12
    • 0023789202 scopus 로고
    • The anatomic basis of femoral component design
    • Noble PC, Alexander JW, Lindahl LJ, et al: The anatomic basis of femoral component design. Clin Orthop 235:148, 1988
    • (1988) Clin Orthop , vol.235 , pp. 148
    • Noble, P.C.1    Alexander, J.W.2    Lindahl, L.J.3
  • 13
    • 0026599455 scopus 로고
    • The morphology of the proximal femur: A three dimensional radiographic analysis
    • Rubin PJ, Leyvraz PF, Aubaniac JM, et al: The morphology of the proximal femur: a three dimensional radiographic analysis. J Bone Joint Surg Br 74:28, 1992
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 28
    • Rubin, P.J.1    Leyvraz, P.F.2    Aubaniac, J.M.3
  • 14
    • 0019057926 scopus 로고
    • Dislocation in total hip arthroplasties
    • Fackler CD, Poss R: Dislocation in total hip arthroplasties. Clin Orthop 151:169, 1980
    • (1980) Clin Orthop , vol.151 , pp. 169
    • Fackler, C.D.1    Poss, R.2
  • 15
    • 0028805203 scopus 로고
    • Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty
    • McGrory BJ, Morrey BF, Cahalan TD, et al: Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br 77:865, 1995
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 865
    • McGrory, B.J.1    Morrey, B.F.2    Cahalan, T.D.3
  • 16
    • 0029146236 scopus 로고
    • The effect of aging on the shape of the proximal femur
    • Noble PC, Box GG, Kamaric E, et al: The effect of aging on the shape of the proximal femur. Clin Orthop 316:31, 1995
    • (1995) Clin Orthop , vol.316 , pp. 31
    • Noble, P.C.1    Box, G.G.2    Kamaric, E.3
  • 17
    • 0023257925 scopus 로고
    • The relationship of neck orientation to the shape of the proximal femur
    • Clark JM, Freeman MA, Witham D: The relationship of neck orientation to the shape of the proximal femur. J Arthroplasty 2:99, 1987
    • (1987) J Arthroplasty , vol.2 , pp. 99
    • Clark, J.M.1    Freeman, M.A.2    Witham, D.3
  • 18
    • 0018877406 scopus 로고
    • The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction
    • Crowninshield RD, Brand RA, Johnston RC, et al: The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction. Clin Orthop 146:71, 1980
    • (1980) Clin Orthop , vol.146 , pp. 71
    • Crowninshield, R.D.1    Brand, R.A.2    Johnston, R.C.3
  • 19
    • 0027732951 scopus 로고
    • Mechanical failure of the femoral component in cemented total hip replacement - A finite element evaluation
    • Jansson V, Refior HJ: Mechanical failure of the femoral component in cemented total hip replacement - a finite element evaluation. Arch Orthop Trauma Surg 113:23, 1993
    • (1993) Arch Orthop Trauma Surg , vol.113 , pp. 23
    • Jansson, V.1    Refior, H.J.2
  • 20
    • 0023903955 scopus 로고
    • Cementless madreporic polarised total hip prostheses: A ten year review of 2688 cases
    • Lord G, Marotte JH, Blanchard JP, et al: Cementless madreporic polarised total hip prostheses: a ten year review of 2688 cases. Rev Chir Orthop 74:3, 1988
    • (1988) Rev Chir Orthop , vol.74 , pp. 3
    • Lord, G.1    Marotte, J.H.2    Blanchard, J.P.3
  • 21
    • 0031657175 scopus 로고    scopus 로고
    • Ten year survivorship of the Zweymüller prosthesis in cementless primary total hip arthroplasty
    • Delaunay C, Kapandji IA: Ten year survivorship of the Zweymüller prosthesis in cementless primary total hip arthroplasty. Rev Chir Orthop 84:421, 1998
    • (1998) Rev Chir Orthop , vol.84 , pp. 421
    • Delaunay, C.1    Kapandji, I.A.2
  • 22
    • 0023946442 scopus 로고
    • The uncemented porous coated anatomic total hip prosthesis: Two-year results of a prospective consecutive series
    • Callaghan JJ, Dysart SH, Savory CG: The uncemented porous coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg Am 70:337, 1988
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 337
    • Callaghan, J.J.1    Dysart, S.H.2    Savory, C.G.3
  • 23
    • 0023174950 scopus 로고
    • Two-year follow-up of the PCA uncemented total hip replacement
    • Brand RA (ed): Mosby, St Louis
    • Hedley AK, Gruen TAW, Borden LS, et al: Two-year follow-up of the PCA uncemented total hip replacement, p 225. In Brand RA (ed): The hip. Mosby, St Louis, 1987
    • (1987) The Hip , pp. 225
    • Hedley, A.K.1    Gruen, T.A.W.2    Borden, L.S.3
  • 24
    • 0026604238 scopus 로고
    • Results of 203 total hip replacements using a smooth cementless femoral component
    • Duparc J, Massin P: Results of 203 total hip replacements using a smooth cementless femoral component. J Bone Joint Surg Br 74:251, 1992
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 251
    • Duparc, J.1    Massin, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.