메뉴 건너뛰기




Volumn 38, Issue 1, 2000, Pages 17-25

A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method

Author keywords

Autonomic regulation; Cardiovascular haemodynamic monitoring; Cardiovascular variables; Electrical admittance plethysmography; Haemodynamic fluctuations; Volume compensation method

Indexed keywords

BIOMEDICAL EQUIPMENT; CARDIOVASCULAR SYSTEM; COMPUTER AIDED DIAGNOSIS; ELECTROPHYSIOLOGY; HEMODYNAMICS; PLETHYSMOGRAPHY; PORTABLE EQUIPMENT; PSYCHOPHYSIOLOGY; SUBJECTIVE TESTING; TIME SERIES ANALYSIS;

EID: 0033968787     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02344683     Document Type: Article
Times cited : (54)

References (29)
  • 1
    • 0015395148 scopus 로고
    • Systolic time intervals as measures of the contractile state of the left ventricular myocardium in man
    • AHMED, S. S., LEVINSON, G. E., SCHWARTZ, C. J. and ETTINGER, P. O. (1972): 'Systolic time intervals as measures of the contractile state of the left ventricular myocardium in man', Circulation, 46, pp. 559-571
    • (1972) Circulation , vol.46 , pp. 559-571
    • Ahmed, S.S.1    Levinson, G.E.2    Schwartz, C.J.3    Ettinger, P.O.4
  • 2
    • 0022979027 scopus 로고
    • Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • BERNSTEIN, D. P. (1986): 'Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance', Crit. Care Med., 14, pp. 898-901
    • (1986) Crit. Care Med. , vol.14 , pp. 898-901
    • Bernstein, D.P.1
  • 3
    • 0028151648 scopus 로고
    • Autonomic cardiac control. II. Noninvasive indices and basal response as revealed by autonomic blockades
    • CACIOPPO, J. T., BERNTSON, G. G., BINKLEY, P. F., QUIGLEY, K. S., UCHINO, B. N. and FIELDSTONE, A. (1994): 'Autonomic cardiac control. II. Noninvasive indices and basal response as revealed by autonomic blockades', Psychophysiology, 31, pp. 586-598
    • (1994) Psychophysiology , vol.31 , pp. 586-598
    • Cacioppo, J.T.1    Berntson, G.G.2    Binkley, P.F.3    Quigley, K.S.4    Uchino, B.N.5    Fieldstone, A.6
  • 8
    • 0017293837 scopus 로고
    • Transthoracic admittance plethysmography for measuring cardiac output
    • ITO, H., YAMAKOSHI, K. and TOGAWA, T. (1976): 'Transthoracic admittance plethysmography for measuring cardiac output', J. Appl. Physiol., 40, pp. 451-454
    • (1976) J. Appl. Physiol. , vol.40 , pp. 451-454
    • Ito, H.1    Yamakoshi, K.2    Togawa, T.3
  • 9
    • 0025965933 scopus 로고
    • Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method
    • KAWARADA, A., SHIMAZU, H., ITO, H. and YAMAKOSHI, K. (1991): 'Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method', Med. Biol. Eng. Comput., 29, pp. 56-62
    • (1991) Med. Biol. Eng. Comput. , vol.29 , pp. 56-62
    • Kawarada, A.1    Shimazu, H.2    Ito, H.3    Yamakoshi, K.4
  • 10
    • 0025362862 scopus 로고
    • An evaluation of the ensemble averaged impedance cardiogram
    • KELSEY, R. M. and GUETHLEIN, W. (1990): 'An evaluation of the ensemble averaged impedance cardiogram', Psychophysiology, 27, pp. 24-33
    • (1990) Psychophysiology , vol.27 , pp. 24-33
    • Kelsey, R.M.1    Guethlein, W.2
  • 11
    • 84981642933 scopus 로고
    • Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system
    • KUBICEK, W., PATTERSON, R. P. and WITSOE, D. A. (1970): 'Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system', Ann. NY Acad Sci., 170, pp. 724-732
    • (1970) Ann. NY Acad Sci. , vol.170 , pp. 724-732
    • Kubicek, W.1    Patterson, R.P.2    Witsoe, D.A.3
  • 13
    • 0343247306 scopus 로고
    • Non-invasive and ambulatory monitoring system for cardiovascular haemodynamic variables - A special interest in comparison test for long-term continuous monitoring of cardiac output determined by invasive and present non-invasive method
    • MAKI, H., NAKAGAWARA, M., YAMAKOSHI, K., NAKASHIMA, K. and MAEKAWA, M. (1995): 'Non-invasive and ambulatory monitoring system for cardiovascular haemodynamic variables - A special interest in comparison test for long-term continuous monitoring of cardiac output determined by invasive and present non-invasive method', Jpn. J. Med. Electron. Biol. Eng., 33, (suppl.), p. 123
    • (1995) Jpn. J. Med. Electron. Biol. Eng. , vol.33 , Issue.SUPPL. , pp. 123
    • Maki, H.1    Nakagawara, M.2    Yamakoshi, K.3    Nakashima, K.4    Maekawa, M.5
  • 15
    • 0002220170 scopus 로고
    • Photoelectric measurement of blood pressure, volume and flow in finger
    • PENAZ, J, (1973): 'Photoelectric measurement of blood pressure, volume and flow in finger'. Dig. 10th ICMBE, p. 104
    • (1973) Dig. 10th ICMBE , pp. 104
    • Penaz, J.1
  • 17
    • 0022812781 scopus 로고
    • Motion artifact from spot and band electrodes during impedance cardiography
    • QU, M., ZHANG, Y., WEBSTER, J. G. and TOMPKINS, W. J. (1986): 'Motion artifact from spot and band electrodes during impedance cardiography', IEEE Trans., BME-33, pp. 1029-1035
    • (1986) IEEE Trans. , vol.BME-33 , pp. 1029-1035
    • Qu, M.1    Zhang, Y.2    Webster, J.G.3    Tompkins, W.J.4
  • 18
    • 0025797449 scopus 로고
    • SA nodal parasympathectomy delineates autonomic control of heart rate power spectrum
    • RANDALL, D. C., BROWN, D. R., RAISCH, R. M., YINGLING, J. D. and RANDALL, W. C. (1991): 'SA nodal parasympathectomy delineates autonomic control of heart rate power spectrum', Am. J. Physiol., 260, pp. H985-H988
    • (1991) Am. J. Physiol. , vol.260
    • Randall, D.C.1    Brown, D.R.2    Raisch, R.M.3    Yingling, J.D.4    Randall, W.C.5
  • 20
    • 0031793753 scopus 로고    scopus 로고
    • Ambulatory impedance cardiography: A feasibility study
    • SHERWOOD, A., MCFETRIDGE, J. and HUTCHESON, S. (1998): 'Ambulatory impedance cardiography: a feasibility study', J. Appl. Physiol., 85, pp. 2365-2369
    • (1998) J. Appl. Physiol. , vol.85 , pp. 2365-2369
    • Sherwood, A.1    Mcfetridge, J.2    Hutcheson, S.3
  • 21
    • 0030292987 scopus 로고    scopus 로고
    • Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method
    • TANAKA, S. and YAMAKOSHI, K. (1996): 'Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method', Med. Biol. Eng. Comput., 34, pp. 441-447
    • (1996) Med. Biol. Eng. Comput. , vol.34 , pp. 441-447
    • Tanaka, S.1    Yamakoshi, K.2
  • 23
    • 0018547136 scopus 로고
    • Indirect measurement of instantaneous arterial blood pressure in the rat
    • YAMAKOSHI, K., SHIMAZU, H. and TOGAWA, T. (1979): 'Indirect measurement of instantaneous arterial blood pressure in the rat', Am J. Physiol., 237, pp. H632-H637
    • (1979) Am J. Physiol. , vol.237
    • Yamakoshi, K.1    Shimazu, H.2    Togawa, T.3
  • 24
    • 0018910811 scopus 로고
    • Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique
    • YAMAKOSHI, K., SHIMAZU, H. and TOGAWA, T. (1980a): 'Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique', IEEE Trans., BME-27, pp. 150-155
    • (1980) IEEE Trans. , vol.BME-27 , pp. 150-155
    • Yamakoshi, K.1    Shimazu, H.2    Togawa, T.3
  • 25
    • 0018910810 scopus 로고
    • Noninvasive measurement of hematocrit by electrical admittance plethysmography technique
    • YAMAKOSHI, K., SHIMAZU, H., TOGAWA, T., FUKUOKA, M. and ITO, H. (1980b): 'Noninvasive measurement of hematocrit by electrical admittance plethysmography technique', IEEE Trans., BME-27, pp. 156-161
    • (1980) IEEE Trans. , vol.BME-27 , pp. 156-161
    • Yamakoshi, K.1    Shimazu, H.2    Togawa, T.3    Fukuoka, M.4    Ito, H.5
  • 26
    • 0020137641 scopus 로고
    • New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1; Model experiment
    • YAMAKOSHI, K., SHIMAZU, H., SHIBATA, M. and KAMIYA, A. (1982a): 'New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1; Model experiment', Med. Biol. Eng. Comput., 20, pp. 307-313
    • (1982) Med. Biol. Eng. Comput. , vol.20 , pp. 307-313
    • Yamakoshi, K.1    Shimazu, H.2    Shibata, M.3    Kamiya, A.4
  • 27
    • 0020137931 scopus 로고
    • New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2; Correlation study
    • YAMAKOSHI, K., SHIMAZU, H., SHIBATA, M. and KAMIYA, A. (1982b): 'New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2; Correlation study', Med. Biol. Eng. Comput., 20, pp. 314-318
    • (1982) Med. Biol. Eng. Comput. , vol.20 , pp. 314-318
    • Yamakoshi, K.1    Shimazu, H.2    Shibata, M.3    Kamiya, A.4
  • 28
    • 0020816081 scopus 로고
    • Non-invasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique
    • YAMAKOSHI, K., KAMIYA, A., SHIMAZU, H., ITO, H. and TOGAWA, T. (1983): 'Non-invasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique', Med. Biol. Eng. Comput., 21, pp. 557-565
    • (1983) Med. Biol. Eng. Comput. , vol.21 , pp. 557-565
    • Yamakoshi, K.1    Kamiya, A.2    Shimazu, H.3    Ito, H.4    Togawa, T.5
  • 29
    • 0028851867 scopus 로고
    • Voltage clamp method for the use of electrical admittance plethysmography in human body segments
    • YAMAKOSHI, K. and NAKAGAWARA, M. (1995): 'Voltage clamp method for the use of electrical admittance plethysmography in human body segments', Med. Biol. Eng. Compt., 33, pp. 740-743
    • (1995) Med. Biol. Eng. Compt. , vol.33 , pp. 740-743
    • Yamakoshi, K.1    Nakagawara, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.