The first-year experience with the dual chamber ICD

Author keywords

Dual chamber pacing; Implantable cardioverter defibrillator; Permanent pacemakers; Sudden death; Ventricular fibrillation; Ventricular tachycardia

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CONGESTIVE HEART FAILURE; CONTROLLED STUDY; DEFIBRILLATOR; FEMALE; FLUOROSCOPY; HEART ATRIUM FIBRILLATION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HEMATOMA; HUMAN; INFECTION; MAJOR CLINICAL STUDY; MALE; PROSPECTIVE STUDY; SICK SINUS SYNDROME; SINUS BRADYCARDIA; SUDDEN DEATH; THORAX RADIOGRAPHY; TREATMENT INDICATION; UNITED STATES;

EID: 0033966672     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2000.tb00645.x     Document Type: Article
Times cited : (17)

References (11)
  • 1
    • 0028077584 scopus 로고
    • Feasiblity of concomitant implantation of permanent transvenous pacemaker and defibrillator systems
    • 1. Blanck Z, Niazi I, Axtell K, et al. Feasiblity of concomitant implantation of permanent transvenous pacemaker and defibrillator systems. Am J Cardiol 1994; 74:1249-1253.
    • (1994) Am J Cardiol , vol.74 , pp. 1249-1253
    • Blanck, Z.1    Niazi, I.2    Axtell, K.3
  • 2
    • 0028589916 scopus 로고
    • Safety of pacemaker implantation in patients with transvenous (nonthoracotomy) implantable cardioverter defibrillators
    • 2. Clemo HF, Ellenbogen KA, Belz MK, et al. Safety of pacemaker implantation in patients with transvenous (nonthoracotomy) implantable cardioverter defibrillators. PACE 1994; 17:2285-2291.
    • (1994) PACE , vol.17 , pp. 2285-2291
    • Clemo, H.F.1    Ellenbogen, K.A.2    Belz, M.K.3
  • 3
    • 0008944025 scopus 로고
    • Interactions between transvenous nonthoracotomy cardioverter defibrillators
    • 3. Geiger MJ, O'Neill P, Sharma A, et al. Interactions between transvenous nonthoracotomy cardioverter defibrillators. PACE 1994; 20:177-181.
    • (1994) PACE , vol.20 , pp. 177-181
    • Geiger, M.J.1    O'Neill, P.2    Sharma, A.3
  • 4
    • 0008955122 scopus 로고
    • How frequently is dual chamber pacing indicated in patients with implantable cardioverter defibrillator?
    • 4. Andrews NP, Gudgel R, Evans JJ, et al. How frequently is dual chamber pacing indicated in patients with implantable cardioverter defibrillator? PACE 1994; 17:274-279.
    • (1994) PACE , vol.17 , pp. 274-279
    • Andrews, N.P.1    Gudgel, R.2    Evans, J.J.3
  • 5
    • 0032104051 scopus 로고    scopus 로고
    • Indications for implantation of a dual-chamber pacemaker combined with an implantable cardioverter-defibrillator
    • 5. Higgins SL, Williams SK, Pak JP, et al. Indications for implantation of a dual-chamber pacemaker combined with an implantable cardioverter-defibrillator. Am J Cardiol 1998; 81:1360-1366.
    • (1998) Am J Cardiol , vol.81 , pp. 1360-1366
    • Higgins, S.L.1    Williams, S.K.2    Pak, J.P.3
  • 6
    • 0032053695 scopus 로고    scopus 로고
    • ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: A report of the American College of Cardiology /American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation)
    • 6. Gregoratos G, Cheitlin MD, Conill A, et al. ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: A report of the American College of Cardiology /American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). J Am Coll Cardiol 1998; 31:1175-1209.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 1175-1209
    • Gregoratos, G.1    Cheitlin, M.D.2    Conill, A.3
  • 8
    • 0025648389 scopus 로고
    • Intravascular lead extraction using locking stylets, sheaths and other techniques
    • 8. Fearnot NE, Smith HJ, Goode LB, et al. Intravascular lead extraction using locking stylets, sheaths and other techniques. PACE 1990; 13:1864-1870.
    • (1990) PACE , vol.13 , pp. 1864-1870
    • Fearnot, N.E.1    Smith, H.J.2    Goode, L.B.3
  • 9
    • 0029051875 scopus 로고
    • The subcutaneous array: A new adjunct for the transvenous ICD to lower defibrillation thresholds
    • 9. Higgins SL, Alexander DC, Kuypers CJ, et al. The subcutaneous array: A new adjunct for the transvenous ICD to lower defibrillation thresholds. PACE 1995; 18:1540-1548.
    • (1995) PACE , vol.18 , pp. 1540-1548
    • Higgins, S.L.1    Alexander, D.C.2    Kuypers, C.J.3
  • 10
    • 85038056377 scopus 로고    scopus 로고
    • August 28, 1998. Personal Communication
    • 10. Voshage-Stahl L. August 28, 1998. Personal Communication.
    • Voshage-Stahl, L.1
  • 11
    • 0031830607 scopus 로고    scopus 로고
    • Triple chamber pacemaker for end-stage heart failure in a patient with a previously implanted automatic defibrillator
    • 11. Le Franc P, Didier K, Lacroix D, et al. Triple chamber pacemaker for end-stage heart failure in a patient with a previously implanted automatic defibrillator. PACE 1998; 21:1672-1675.
    • (1998) PACE , vol.21 , pp. 1672-1675
    • Le Franc, P.1    Didier, K.2    Lacroix, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.