Improved dialyzer reuse after use of a population pharmacodynamic model to determine heparin doses

Author keywords

Anticoagulation; Dialyzer reuse; Hemodialysis (HD); Heparin; Modeling

Indexed keywords

ANTICOAGULANT AGENT; HEPARIN;

EID: 0033960937     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0272-6386(00)70306-4     Document Type: Article
Times cited : (21)

References (14)
  • 1
    • 0021714617 scopus 로고
    • Heparin elimination and hemostasis in hemodialysis
    • S Wilhelmsson L-E Lins Heparin elimination and hemostasis in hemodialysis Clin Nephrol 22 1984 303 306
    • (1984) Clin Nephrol , vol.22 , pp. 303-306
    • Wilhelmsson, S1    Lins, L-E2
  • 2
    • 0025064960 scopus 로고
    • Pharmacokinetics and pharmacodynamics of heparin during hemodialysis: Interpatient and intrapatient variability
    • RJ Kandrotas P Gal JB Douglas J Deterding Pharmacokinetics and pharmacodynamics of heparin during hemodialysis: Interpatient and intrapatient variability Pharmacotherapy 10 1990 349 356
    • (1990) Pharmacotherapy , vol.10 , pp. 349-356
    • Kandrotas, RJ1    Gal, P2    Douglas, JB3    Deterding, J4
  • 4
    • 0028349576 scopus 로고
    • Adaptive control of anticoagulation during hemodialysis
    • TC Jannett MG Wise NH Shanklin PW Sanders Adaptive control of anticoagulation during hemodialysis Kidney Int 45 1994 912 915
    • (1994) Kidney Int , vol.45 , pp. 912-915
    • Jannett, TC1    Wise, MG2    Shanklin, NH3    Sanders, PW4
  • 5
    • 0031781431 scopus 로고    scopus 로고
    • Prediction of anticoagulation during hemodialysis by population kinetics and an artificial neural network
    • BP Smith RA Ward ME Brier Prediction of anticoagulation during hemodialysis by population kinetics and an artificial neural network Artif Organs 22 1998 731 739
    • (1998) Artif Organs , vol.22 , pp. 731-739
    • Smith, BP1    Ward, RA2    Brier, ME3
  • 6
    • 0027688501 scopus 로고
    • Second-generation logarithmic estimates of single-pool variable volume Kt/V: An analysis of error
    • JT Daugirdas Second-generation logarithmic estimates of single-pool variable volume Kt/V: An analysis of error J Am Soc Nephrol 4 1993 1205 1213
    • (1993) J Am Soc Nephrol , vol.4 , pp. 1205-1213
    • Daugirdas, JT1
  • 7
    • 0031883074 scopus 로고    scopus 로고
    • National surveillance of dialysis-associated diseases in the United States, 1995
    • JI Tokars ER Miller MJ Alter MJ Arduino National surveillance of dialysis-associated diseases in the United States, 1995 ASAIO J 44 1998 98 107
    • (1998) ASAIO J , vol.44 , pp. 98-107
    • Tokars, JI1    Miller, ER2    Alter, MJ3    Arduino, MJ4
  • 8
    • 0019234518 scopus 로고
    • Mass transport in reused dialyzers
    • FA Gotch Mass transport in reused dialyzers Proc Dial Transplant Forum 10 1980 81 85
    • (1980) Proc Dial Transplant Forum , vol.10 , pp. 81-85
    • Gotch, FA1
  • 9
    • 0029382464 scopus 로고
    • Heparinization for routine hemodialysis
    • RA Ward Heparinization for routine hemodialysis Adv Ren Replace Ther 2 1995 362 370
    • (1995) Adv Ren Replace Ther , vol.2 , pp. 362-370
    • Ward, RA1
  • 10
    • 0029621219 scopus 로고
    • Effects of haemodialysis on coagulation and platelets: Are we measuring membrane biocompatibility?
    • RA Ward Effects of haemodialysis on coagulation and platelets: Are we measuring membrane biocompatibility? Nephrol Dial Transplant 10 suppl 10 1995 S12 S17
    • (1995) Nephrol Dial Transplant , vol.10 , Issue.suppl 10 , pp. S12-S17
    • Ward, RA1
  • 11
    • 85120112067 scopus 로고
    • Reuse of Hemodialyzers (ANSI/AAMI RD47-1993)
    • Association for the Advancement of Medical Instrumentation Reuse of Hemodialyzers (ANSI/AAMI RD47-1993) 1993 Association for the Advancement of Medical Instrumentation Arlington, VA
    • (1993)
    • Association for the Advancement of Medical Instrumentation1
  • 13
    • 0028345633 scopus 로고
    • Effect of heparin modeling on delivered hemodialysis therapy
    • SS Wei PW Ellis MO Magnusson EP Paganini Effect of heparin modeling on delivered hemodialysis therapy Am J Kidney Dis 23 1994 389 393
    • (1994) Am J Kidney Dis , vol.23 , pp. 389-393
    • Wei, SS1    Ellis, PW2    Magnusson, MO3    Paganini, EP4
  • 14
    • 0011801531 scopus 로고
    • Heparin as an anticoagulant during extracorporeal circulation
    • H Ireland PB Rylance P Kesteven Heparin as an anticoagulant during extracorporeal circulation DA Lane U Lindahl Heparin. Chemical and Biological Properties, Clinical Applications 1989 Arnold London, England 549 574
    • (1989) , pp. 549-574
    • Ireland, H1    Rylance, PB2    Kesteven, P3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.