메뉴 건너뛰기




Volumn 46, Issue 1, 2000, Pages 65-69

Variable flow Doppler for hemodialysis access evaluation: Theory and clinical feasibility

Author keywords

[No Author keywords available]

Indexed keywords

DIALYSIS; DOPPLER EFFECT; FLOW MEASUREMENT; FLOW PATTERNS; PATIENT TREATMENT; ULTRASONIC MEASUREMENT;

EID: 0033956672     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-200001000-00018     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 0031463650 scopus 로고    scopus 로고
    • Predictive measures of vascular access thrombosis: A prospective study
    • May RE, Himmelfarb J, Yenicesu M, et al: Predictive measures of vascular access thrombosis: a prospective study. Kidney Int 52: 1656-1662, 1997.
    • (1997) Kidney Int , vol.52 , pp. 1656-1662
    • May, R.E.1    Himmelfarb, J.2    Yenicesu, M.3
  • 3
    • 0032170885 scopus 로고    scopus 로고
    • Predictive value of access blood flow in detecting access thrombosis
    • Wang E, Schneditz D, Nepomuceno C, et al: Predictive value of access blood flow in detecting access thrombosis. ASAIO J 44: M555-M558, 1998.
    • (1998) ASAIO J , vol.44
    • Wang, E.1    Schneditz, D.2    Nepomuceno, C.3
  • 4
    • 0028836053 scopus 로고
    • Study of vascular access by angiodynography
    • Kirshbaum B, Compton A: Study of vascular access by angiodynography. Am J Kidney Dis 25: 22-25, 1995.
    • (1995) Am J Kidney Dis , vol.25 , pp. 22-25
    • Kirshbaum, B.1    Compton, A.2
  • 5
    • 0027670411 scopus 로고
    • Duplex and color sonography of hemodialysis arteriovenous fistulas and grafts
    • Findley DE, Longley DC, Foshager MC, Letourneau JG: Duplex and color sonography of hemodialysis arteriovenous fistulas and grafts. Radiographics 13: 983-999, 1993.
    • (1993) Radiographics , vol.13 , pp. 983-999
    • Findley, D.E.1    Longley, D.C.2    Foshager, M.C.3    Letourneau, J.G.4
  • 6
    • 0031907829 scopus 로고    scopus 로고
    • The role of color-flow Doppler ultrasound in the management of hemodialysis accesses
    • Sands J: The role of color-flow Doppler ultrasound in the management of hemodialysis accesses. ASAIO J 44: 41-43, 1998.
    • (1998) ASAIO J , vol.44 , pp. 41-43
    • Sands, J.1
  • 8
    • 0029048657 scopus 로고
    • Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenosis prior to thrombosis
    • Besarab A, Sullivan KL, Ross RP, Moritz MJ: Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenosis prior to thrombosis. Kidney Int 47: 1364-1373, 1995.
    • (1995) Kidney Int , vol.47 , pp. 1364-1373
    • Besarab, A.1    Sullivan, K.L.2    Ross, R.P.3    Moritz, M.J.4
  • 9
    • 0031930135 scopus 로고    scopus 로고
    • The prevention of access failure: Pressure monitoring
    • Besarab A, Frinak S: The prevention of access failure: Pressure monitoring. ASAIO J 44: 35-37, 1998.
    • (1998) ASAIO J , vol.44 , pp. 35-37
    • Besarab, A.1    Frinak, S.2
  • 11
    • 0030933211 scopus 로고    scopus 로고
    • The relationship of recirculation to access blood flow
    • Besarab A, Sherman R: The relationship of recirculation to access blood flow. Am J Kidney Dis 29: 223-229, 1997.
    • (1997) Am J Kidney Dis , vol.29 , pp. 223-229
    • Besarab, A.1    Sherman, R.2
  • 12
    • 0031882934 scopus 로고    scopus 로고
    • Hemodialysis access: In-line methods
    • Depner TA: Hemodialysis access: in-line methods. ASAIO J 44: 38-39, 1998.
    • (1998) ASAIO J , vol.44 , pp. 38-39
    • Depner, T.A.1
  • 13
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • Krivitski NM: Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 48:244-250, 1995.
    • (1995) Kidney Int , vol.48 , pp. 244-250
    • Krivitski, N.M.1
  • 14
    • 0030372749 scopus 로고    scopus 로고
    • Access flow measurements in Hemodialysis Patients: In vivo validation of an ultrasound dilution technique
    • Brosman PJ, Boereboom FTJ, Bakker CJ, et al: Access flow measurements in Hemodialysis Patients: In vivo validation of an ultrasound dilution technique. J Am Soc Nephrol 7: 966-969, 1996.
    • (1996) J Am Soc Nephrol , vol.7 , pp. 966-969
    • Brosman, P.J.1    Boereboom, F.T.J.2    Bakker, C.J.3
  • 15
    • 0031931496 scopus 로고    scopus 로고
    • A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate
    • Lindsay RM, Bradfield E, Rothera C, Kianfar C, Malek P, Blake PG: A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate. ASAIO J 44: 62-67, 1998.
    • (1998) ASAIO J , vol.44 , pp. 62-67
    • Lindsay, R.M.1    Bradfield, E.2    Rothera, C.3    Kianfar, C.4    Malek, P.5    Blake, P.G.6
  • 16
    • 4243806653 scopus 로고
    • Non-invasive quantitative measurement of hemodialysis access graft (HG) flow
    • Abstract 23
    • Keen M, Presig P, Gotch F: Non-invasive quantitative measurement of hemodialysis access graft (HG) flow (Abstract 23). J Am Soc Nephrol 17: 68a, 1985.
    • (1985) J Am Soc Nephrol , vol.17
    • Keen, M.1    Presig, P.2    Gotch, F.3
  • 17
    • 0025457138 scopus 로고
    • Pressure effects on roller pump flow during hemodialysis
    • Depner TA, Rizwan S, Sasi TA: Pressure effects on roller pump flow during hemodialysis. ASAIO Trans 31: M456-M459, 1990.
    • (1990) ASAIO Trans , vol.31
    • Depner, T.A.1    Rizwan, S.2    Sasi, T.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.