메뉴 건너뛰기




Volumn 45, Issue 2, 2000, Pages 267-277

Photon fluence perturbation correction factors for solid state detectors irradiated in kilovoltage photon beams

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM FLUORIDE; LITHIUM DERIVATIVE; LITHIUM FLUORIDE; WATER;

EID: 0033953977     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/45/2/302     Document Type: Article
Times cited : (12)

References (16)
  • 2
    • 0023138959 scopus 로고
    • PRESTA - The parameter reduced electron step size algorithm for electron Monte Carlo transport
    • Bielajew A F and Rogers D W O 1987 PRESTA - the parameter reduced electron step size algorithm for electron Monte Carlo transport Nucl. Instrum. Methods B 18 165-81
    • (1987) Nucl. Instrum. Methods B , vol.18 , pp. 165-181
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 3
    • 0022535571 scopus 로고
    • The dependence of the mass energy absorption coefficient ratios on the beam size and depth in a phantom
    • Cunningham J R, Woo M, Rogers D W O and Bielajew A F 1986 The dependence of the mass energy absorption coefficient ratios on the beam size and depth in a phantom Med. Phys. 13 496-502
    • (1986) Med. Phys. , vol.13 , pp. 496-502
    • Cunningham, J.R.1    Woo, M.2    Rogers, D.W.O.3    Bielajew, A.F.4
  • 4
  • 5
    • 0001351569 scopus 로고
    • Tables of x-rays mass attenuation coefficients and mass energy absorption coefficient 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest
    • NISTIR 5632
    • Hubbell J H and Seltzer S M 1995 Tables of x-rays mass attenuation coefficients and mass energy absorption coefficient 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest NIST Report NISTIR 5632
    • (1995) NIST Report
    • Hubbell, J.H.1    Seltzer, S.M.2
  • 6
    • 0029846001 scopus 로고    scopus 로고
    • Code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential)
    • Institution of Physics and Engineering in Medicine and Biology (IPEMB) 1996 Code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential) Phys. Med. Biol. 41 2605-25
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2605-2625
  • 8
    • 0002435589 scopus 로고
    • Depth and field-size dependence of ratios of mass energy absorption coefficient, water to air, for kV x-rays dosimetry
    • Vienna, 1993 IAEA-SM-330/17 (Vienna: IAEA)
    • Knight R T and Nahum A E 1994 Depth and field-size dependence of ratios of mass energy absorption coefficient, water to air, for kV x-rays dosimetry Proc. Int. Symp. on Measurement Assurance in Dosimetry (Vienna, 1993) IAEA-SM-330/17 (Vienna: IAEA) 361-79
    • (1994) Proc. Int. Symp. on Measurement Assurance in Dosimetry , pp. 361-379
    • Knight, R.T.1    Nahum, A.E.2
  • 9
    • 0006698877 scopus 로고
    • PhD Thesis University of London (Available as internal report ICR-PHYS-1/92 from the Physics Department, Institute of Cancer Research, Sutton SM2 5PT, UK)
    • Ma C-M 1992 Monte Carlo simulation of dosimeter response using transputers PhD Thesis University of London (Available as internal report ICR-PHYS-1/92 from the Physics Department, Institute of Cancer Research, Sutton SM2 5PT, UK)
    • (1992) Monte Carlo Simulation of Dosimeter Response Using Transputers
    • Ma, C.-M.1
  • 10
    • 0027250302 scopus 로고
    • Calculation of absorbed dose ratios using correlated Monte Carlo sampling
    • Ma C-M and Nahum A E 1993 Calculation of absorbed dose ratios using correlated Monte Carlo sampling Med. Phys. 20 1189-99
    • (1993) Med. Phys. , vol.20 , pp. 1189-1199
    • Ma, C.-M.A.1    Nahum, A.E.2
  • 12
    • 0029922271 scopus 로고    scopus 로고
    • Quality dependence of LiF-TLD in megavoltage photon beams: Monte Carlo simulation and experiments
    • Mobit P N, Mayles P and Nahum A E 1996 Quality dependence of LiF-TLD in megavoltage photon beams: Monte Carlo simulation and experiments Phys. Med. Biol. 41 379-98
    • (1996) Phys. Med. Biol. , vol.41 , pp. 379-398
    • Mobit, P.N.1    Mayles, P.2    Nahum, A.E.3
  • 13
    • 0030837107 scopus 로고    scopus 로고
    • An EGS4 Monte Carlo examination of general cavity
    • Mobit P N, Nahum A E and Mayles P 1997 An EGS4 Monte Carlo examination of general cavity Phys. Med. Biol. 42 1319-34
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1319-1334
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3
  • 14
    • 0031855026 scopus 로고    scopus 로고
    • A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams
    • Mobit P N, Nahum A E and Mayles P 1998 A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams Phys. Med. Biol. 43 2015-32
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2015-2032
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3
  • 15
    • 0029821641 scopus 로고    scopus 로고
    • Perturbation effects in dosimetry: Part I. Kilovoltage x-rays and electrons
    • Nahum A E 1996 Perturbation effects in dosimetry: Part I. Kilovoltage x-rays and electrons Phys. Med. Biol. 41 1531-80
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1531-1580
    • Nahum, A.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.