The effect of lung injury and excessive lung fluid, on impedance cardiac output measurements, in the critically ill

Author keywords

Bioimpedance; Cardiac output; Lung injury score; Pulmonary oedema; Sepsis; Thermodilution

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTERY CATHETER; ARTICLE; CLINICAL ARTICLE; CRITICAL ILLNESS; DISEASE ASSOCIATION; FEMALE; HEART OUTPUT; HUMAN; HUMAN TISSUE; IMPEDANCE; LUNG EDEMA; LUNG FLUID; LUNG INJURY; MALE; MEASUREMENT; SEPSIS; THERMODILUTION;

EID: 0033948116     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001340051232     Document Type: Article
Times cited : (49)

References (35)
  • 1
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients
    • 1. Connors AF Jr, Speroff T, Dawson NV, et al (1996) The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA 276: 889-897
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors A.F., Jr.1    Speroff, T.2    Dawson, N.V.3
  • 2
    • 0027201173 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output - Not ready for prime time
    • 2. Clarke DE, Raffin TA (1993) Thoracic electrical bioimpedance measurement of cardiac output - not ready for prime time. Crit Care Med 21: 1111-1112
    • (1993) Crit Care Med , vol.21 , pp. 1111-1112
    • Clarke, D.E.1    Raffin, T.A.2
  • 3
    • 0027303341 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients
    • 3. Sageman WS, Amundson DE (1993) Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients. Crit Care Med 21: 1139-1142
    • (1993) Crit Care Med , vol.21 , pp. 1139-1142
    • Sageman, W.S.1    Amundson, D.E.2
  • 4
    • 0030823296 scopus 로고    scopus 로고
    • Electrical bioimpedance for noninvasive measurement of cardiac output
    • 4. Weil MH (1997) Electrical bioimpedance for noninvasive measurement of cardiac output. Crit Care Med 25: 1455
    • (1997) Crit Care Med , vol.25 , pp. 1455
    • Weil, M.H.1
  • 5
    • 0027458319 scopus 로고
    • Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis
    • 5. Young JD, McQuillan P (1993) Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis. Br J Anaesth 70: 58-62
    • (1993) Br J Anaesth , vol.70 , pp. 58-62
    • Young, J.D.1    McQuillan, P.2
  • 6
    • 0030914204 scopus 로고    scopus 로고
    • Noninvasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man
    • 6. Critchley LA, Conway F, Anderson PJ, Tomlinson B, Critchley JA (1997) Noninvasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man. Clin Auton Res 7: 97-101
    • (1997) Clin Auton Res , vol.7 , pp. 97-101
    • Critchley, L.A.1    Conway, F.2    Anderson, P.J.3    Tomlinson, B.4    Critchley, J.A.5
  • 8
    • 0025835443 scopus 로고
    • Comparison and reproducibility of transthoracic bioimpedance and dual beam doppler ultrasound measurement of cardiac function in healthy volunteers
    • 8. Ng HW, Walley T, Tsao Y, Breckenridge AM (1991) Comparison and reproducibility of transthoracic bioimpedance and dual beam Doppler ultrasound measurement of cardiac function in healthy volunteers. Br J Clin Pharmacol 32: 275-282
    • (1991) Br J Clin Pharmacol , vol.32 , pp. 275-282
    • Ng, H.W.1    Walley, T.2    Tsao, Y.3    Breckenridge, A.M.4
  • 9
    • 0026613990 scopus 로고
    • Impedance cardiography using the Sramek-Bernstein method: Accuracy and variability at rest and during exercise
    • 9. Thomas SH (1992) Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise. Br J Clin Pharmacol 34: 467-476
    • (1992) Br J Clin Pharmacol , vol.34 , pp. 467-476
    • Thomas, S.H.1
  • 10
    • 0031966373 scopus 로고    scopus 로고
    • Lung fluid and impedance cardiography
    • 10. Critchley LA, Critchley JA (1998) Lung fluid and impedance cardiography. Anaesthesia 53: 369-372
    • (1998) Anaesthesia , vol.53 , pp. 369-372
    • Critchley, L.A.1    Critchley, J.A.2
  • 11
    • 0022152605 scopus 로고
    • Evaluation of the portable chest roentgenogram for quantitating extravascular lung water in critically ill adults
    • 11. Halperin BD, Feeley TW, Mihm FG, Chiles C, Guthaner DF, Blank NE (1985) Evaluation of the portable chest roentgenogram for quantitating extravascular lung water in critically ill adults. Chest 88: 649-652
    • (1985) Chest , vol.88 , pp. 649-652
    • Halperin, B.D.1    Feeley, T.W.2    Mihm, F.G.3    Chiles, C.4    Guthaner, D.F.5    Blank, N.E.6
  • 12
    • 0023719313 scopus 로고
    • An expanded definition of the adult respiratory distress syndrome
    • 12. Murray JF, Matthay MA, Luce JM, Flick MR (1988) An expanded definition of the adult respiratory distress syndrome. Am Rev Respir Dis 138: 720-723
    • (1988) Am Rev Respir Dis , vol.138 , pp. 720-723
    • Murray, J.F.1    Matthay, M.A.2    Luce, J.M.3    Flick, M.R.4
  • 14
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • 14. Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15: 85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 15. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8: 307-310
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0022872571 scopus 로고
    • Comparison of transthoracic electrical impedance and thermodilution methods for measuring cardiac output
    • 16. Donovan KD, Dobb GJ, Woods WP, Hockings B (1986) Comparison of transthoracic electrical impedance and thermodilution methods for measuring cardiac output. Crit Care Med 14: 1038-1044
    • (1986) Crit Care Med , vol.14 , pp. 1038-1044
    • Donovan, K.D.1    Dobb, G.J.2    Woods, W.P.3    Hockings, B.4
  • 17
    • 0024364123 scopus 로고
    • Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation
    • 17. Preiser JC, Daper A, Parquier JN, Contempre B, Vincent JL (1989) Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation. Intensive Care Med 15: 221-223
    • (1989) Intensive Care Med , vol.15 , pp. 221-223
    • Preiser, J.C.1    Daper, A.2    Parquier, J.N.3    Contempre, B.4    Vincent, J.L.5
  • 18
    • 0025361628 scopus 로고
    • Noninvasive cardiac output: Simultaneous comparison of two different methods with thermodilution
    • 18. Wong DH, Tremper KK, Stemmer EA, et al (1990) Noninvasive cardiac output: simultaneous comparison of two different methods with thermodilution. Anesthesiology 72: 784-792
    • (1990) Anesthesiology , vol.72 , pp. 784-792
    • Wong, D.H.1    Tremper, K.K.2    Stemmer, E.A.3
  • 19
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • 19. Bernstein DP (1986) A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale. Crit Care Med 14: 904-909
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 20
    • 0031830393 scopus 로고    scopus 로고
    • Impedance cardiography. The impact of new technology
    • 20. Critchley LA (1998) Impedance cardiography. The impact of new technology. Anaesthesia 53: 677-684
    • (1998) Anaesthesia , vol.53 , pp. 677-684
    • Critchley, L.A.1
  • 21
    • 0020332490 scopus 로고
    • The measurement of extravascular lung water by thermal-green dye indicator dilution
    • 21. Lewis FR, Elings VB, Hill SL, Christensen JM (1982) The measurement of extravascular lung water by thermal-green dye indicator dilution. Ann N Y Acad Sci 384: 394-410
    • (1982) Ann N Y Acad Sci , vol.384 , pp. 394-410
    • Lewis, F.R.1    Elings, V.B.2    Hill, S.L.3    Christensen, J.M.4
  • 22
    • 0014884061 scopus 로고    scopus 로고
    • Impedance plethysmography: A noninvasive means of monitoring the thoracic surgery patient
    • 22. Van de Water JM, Miller IT, Milne EN, et al (1997) Impedance plethysmography: a noninvasive means of monitoring the thoracic surgery patient. J Thorac Cardiovasc Surg 60: 641-647
    • (1997) J Thorac Cardiovasc Surg , vol.60 , pp. 641-647
    • Van De Water, J.M.1    Miller, I.T.2    Milne, E.N.3
  • 23
    • 0024822374 scopus 로고
    • Noninvasive estimation of extravascular lung water using bioimpedance
    • 23. Spinale FG, Reines HD, Cook MC, Crawford FA (1989) Noninvasive estimation of extravascular lung water using bioimpedance. J Surg Res 47: 535-540
    • (1989) J Surg Res , vol.47 , pp. 535-540
    • Spinale, F.G.1    Reines, H.D.2    Cook, M.C.3    Crawford, F.A.4
  • 24
    • 0025369372 scopus 로고    scopus 로고
    • Bioimpedance: A novel method for the determination of extravascular lung water
    • 24. Zellner JL, Spinale FG, Crawford FA (1999) Bioimpedance: a novel method for the determination of extravascular lung water. J Surg Res 48: 454-459
    • (1999) J Surg Res , vol.48 , pp. 454-459
    • Zellner, J.L.1    Spinale, F.G.2    Crawford, F.A.3
  • 25
    • 0018643024 scopus 로고
    • Evaluation of transthoracic electrical impedance in the diagnosis of pulmonary edema
    • 25. Fein A, Grossman RF, Jones JG, Goodman PC, Murray JF (1979) Evaluation of transthoracic electrical impedance in the diagnosis of pulmonary edema. Circulation 60: 1156-1160
    • (1979) Circulation , vol.60 , pp. 1156-1160
    • Fein, A.1    Grossman, R.F.2    Jones, J.G.3    Goodman, P.C.4    Murray, J.F.5
  • 26
    • 85047677418 scopus 로고    scopus 로고
    • Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure
    • 26. Spinale FG, Hendrick DA, Crawford FA, Carabello BA (1999) Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure. Cardiovasc Res 24: 423-429
    • (1999) Cardiovasc Res , vol.24 , pp. 423-429
    • Spinale, F.G.1    Hendrick, D.A.2    Crawford, F.A.3    Carabello, B.A.4
  • 27
    • 0021990279 scopus 로고
    • Transthoracic electrical impedance as an index of extracellular fluid volume in man
    • 27. Roos JC, Koomans HA, Boer P, Dorhout Mees EJ (1985) Transthoracic electrical impedance as an index of extracellular fluid volume in man. Intensive Care Med 11: 39-42
    • (1985) Intensive Care Med , vol.11 , pp. 39-42
    • Roos, J.C.1    Koomans, H.A.2    Boer, P.3    Dorhout Mees, E.J.4
  • 29
    • 0021886055 scopus 로고
    • The radiologic distinction of cardiogenic and noncardiogenic edema
    • 29. Milne EN, Pistolesi M, Miniati M, Giuntini C (1985) The radiologic distinction of cardiogenic and noncardiogenic edema. AJR Am J Roentgenol 144: 879-894
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 879-894
    • Milne, E.N.1    Pistolesi, M.2    Miniati, M.3    Giuntini, C.4
  • 30
    • 0019448880 scopus 로고
    • The radiographic detection of acute pulmonary oedema. A comparison of radiographic appearances, densitometry and lung water in dogs
    • 30. Snashall PD, Keyes SJ, Morgan BM, et al (1981) The radiographic detection of acute pulmonary oedema. A comparison of radiographic appearances, densitometry and lung water in dogs. Br J Radiol 54: 277-288
    • (1981) Br J Radiol , vol.54 , pp. 277-288
    • Snashall, P.D.1    Keyes, S.J.2    Morgan, B.M.3
  • 31
    • 0022979027 scopus 로고
    • Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • 31. Bernstein DP (1986) Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit Care Med 14: 898-901
    • (1986) Crit Care Med , vol.14 , pp. 898-901
    • Bernstein, D.P.1
  • 32
    • 0027971947 scopus 로고
    • Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation
    • 32. Shoemaker WC, Wo CC, Bishop MH, et al (1994) Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation. Crit Care Med 22: 1907-1912
    • (1994) Crit Care Med , vol.22 , pp. 1907-1912
    • Shoemaker, W.C.1    Wo, C.C.2    Bishop, M.H.3
  • 33
    • 0029056066 scopus 로고
    • Cardiac output measurement: Lack of agreement between thermodilution and thoracic electric bioimpedance in two clinical settings
    • 33. Atallah MM, Demain AD (1995) Cardiac output measurement: lack of agreement between thermodilution and thoracic electric bioimpedance in two clinical settings. J Clin Anesth 7: 182-185
    • (1995) J Clin Anesth , vol.7 , pp. 182-185
    • Atallah, M.M.1    Demain, A.D.2
  • 34
    • 0022975760 scopus 로고
    • Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients
    • 34. Appel PL, Kram HB, Mackabee J, Fleming AW, Shoemaker WC (1986) Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med 14: 933-935
    • (1986) Crit Care Med , vol.14 , pp. 933-935
    • Appel, P.L.1    Kram, H.B.2    Mackabee, J.3    Fleming, A.W.4    Shoemaker, W.C.5
  • 35


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.