메뉴 건너뛰기




Volumn 12, Issue 1, 2000, Pages 171-176

Potential MR hazard to patients with metallic heart valves: The Lenz effect

Author keywords

Artificial heart valve; Mechanical; MRI; Safety

Indexed keywords

BORON; CARBON; CHROMIUM; FERROMAGNETIC MATERIAL; IRON; MANGANESE; METAL; MOLYBDENUM; NICKEL; PHOSPHORUS; SILICON; TITANIUM; TUNGSTEN;

EID: 0033945859     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/1522-2586(200007)12:1<171::AID-JMRI19>3.0.CO;2-W     Document Type: Article
Times cited : (48)

References (24)
  • 2
    • 0028509215 scopus 로고
    • Ex vivo evaluation of ferromagnetism heating, and artifacts produced by heart valve prostheses exposed to a 1.5 T system
    • Shellock F., Morisoli S. Ex vivo evaluation of ferromagnetism heating, and artifacts produced by heart valve prostheses exposed to a 1.5 T system. J Magn Reson Imaging 1994;4:756-758.
    • (1994) J Magn Reson Imaging , vol.4 , pp. 756-758
    • Shellock, F.1    Morisoli, S.2
  • 4
    • 0023708255 scopus 로고
    • Randell P, Kohman L, Scalzetti E, Szeverenyi N, Panicek D. MRI of prosthetic cardiac valves in vitro and in vivo. Am J Cardiol 1988; 62: 1988;62:973-976.
    • (1988) Am J Cardiol , vol.62 , pp. 973-976
  • 5
    • 0022802163 scopus 로고
    • Effect of magnetic fields used in MRI on 15 prosthetic heart valves
    • Hassler M, le Bas J, Wolf E. Effect of magnetic fields used in MRI on 15 prosthetic heart valves. J Radiol 1986;67:661-666.
    • (1986) J Radiol , vol.67 , pp. 661-666
    • Hassler, M.1    Le Bas, J.2    Wolf, E.3
  • 7
    • 0000047610 scopus 로고
    • MRI of prosthetic heart valves
    • Soulen R. MRI of prosthetic heart valves [Letter]. Radiology 1986; 158:279.
    • (1986) Radiology , vol.158 , pp. 279
    • Soulen, R.1
  • 8
    • 0032802121 scopus 로고    scopus 로고
    • MRI in patients with intraspinal bullets
    • Shellock F. MRI in patients with intraspinal bullets [Letter]. J Magn Reson Imaging 1999;10:107.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 107
    • Shellock, F.1
  • 11
    • 0342339763 scopus 로고
    • Flow dynamics across the Bjork-Shiley tilting disc valve in the mitral position
    • Kalmanson D, editor. London: Edward Arnold
    • Bjork V. Henze A. Flow dynamics across the Bjork-Shiley Tilting disc valve in the mitral position. In: Kalmanson D, editor. The mitral valve; a pluridisciplinary approach. London: Edward Arnold; 1976. p 239-245.
    • (1976) The Mitral Valve; a Pluridisciplinary Approach , pp. 239-245
    • Bjork, V.1    Henze, A.2
  • 12
    • 0006728510 scopus 로고
    • Cardiovascular implants
    • New York: Van Vostrand Reinhold
    • Lynch W. Cardiovascular implants. In: Implants. New York: Van Vostrand Reinhold; 1982. p 48-94
    • (1982) Implants , pp. 48-94
    • Lynch, W.1
  • 13
    • 0022216290 scopus 로고
    • Experimental study of physiological pulsatile flow past valve prostheses in a model of human aorta - II. Tilting disc valves and the effect of orientation
    • Chandran K, Khalighi B, Chen C-J. Experimental study of physiological pulsatile flow past valve prostheses in a model of human aorta - II. Tilting disc valves and the effect of orientation. J Biomech 1985;18:773-780.
    • (1985) J Biomech , vol.18 , pp. 773-780
    • Chandran, K.1    Khalighi, B.2    Chen, C.-J.3
  • 18
    • 0006728511 scopus 로고
    • Clinical laboratory assessment of prosthetic heart valves
    • Barbenel J, Fisher A, Gaylor J, Angerson W, Sheldon C, editors. Oxford: Clarendon Press
    • Wheatley D. Clinical laboratory assessment of prosthetic heart valves. In: Barbenel J, Fisher A, Gaylor J, Angerson W, Sheldon C, editors. Blood flow in artificial organs and cardiovascular prostheses. Oxford: Clarendon Press; 1989. p 14-21.
    • (1989) Blood Flow in Artificial Organs and Cardiovascular Prostheses , pp. 14-21
    • Wheatley, D.1
  • 19
  • 20
    • 0028877216 scopus 로고
    • Evaluation of tilting disc valves after fatigue life testing: Preliminary results within a comparison program
    • Barbaro V, Boccanera G, Daniele C, Grigioni M, Palombo A. Evaluation of tilting disc valves after fatigue life testing: preliminary results within a comparison program. Artif Organs 1995;19:921-927.
    • (1995) Artif Organs , vol.19 , pp. 921-927
    • Barbaro, V.1    Boccanera, G.2    Daniele, C.3    Grigioni, M.4    Palombo, A.5
  • 21
    • 0022643216 scopus 로고
    • A comparative in vitro study of the closing characteristics of Bjork-Shiley and Bicer-Val tilting disc mitral valve prostheses
    • Willshaw P, Biagetti M, Pichel R. A comparative in vitro study of the closing characteristics of Bjork-Shiley and Bicer-Val tilting disc mitral valve prostheses. J Biomed Eng 1986;8:43-48.
    • (1986) J Biomed Eng , vol.8 , pp. 43-48
    • Willshaw, P.1    Biagetti, M.2    Pichel, R.3
  • 22
    • 0022668967 scopus 로고
    • Design of a function test apparatus for prosthetic heart valves. Initial results in the mitral position
    • Fisher J, Jack J, Wheatley D. Design of a function test apparatus for prosthetic heart valves. Initial results in the mitral position. Clin Phys Physiol Meas 1986;6:63-73.
    • (1986) Clin Phys Physiol Meas , vol.6 , pp. 63-73
    • Fisher, J.1    Jack, J.2    Wheatley, D.3
  • 23
    • 0027173880 scopus 로고
    • Placement of ferromagnetic aneurysm clip in a magnetic field with fatal outcome
    • Klucznik R, Carrier D, Pyka R, Haid R. Placement of ferromagnetic aneurysm clip in a magnetic field with fatal outcome. Radiology 1993;187:855-856.
    • (1993) Radiology , vol.187 , pp. 855-856
    • Klucznik, R.1    Carrier, D.2    Pyka, R.3    Haid, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.