메뉴 건너뛰기




Volumn 45, Issue 6, 2000, Pages 636-645

Special problems in aerosol delivery: Artificial airways

Author keywords

Deposition; Endotracheal tube; Intubation; Mechanical ventilation; Metered dose inhaler; Nebulizer; Tracheostomy tube

Indexed keywords

AEROSOL; AIRWAY; ARTIFICIAL VENTILATION; CONFERENCE PAPER; DRUG DELIVERY SYSTEM; ENDOTRACHEAL TUBE; METERED DOSE INHALER; NEBULIZER;

EID: 0033944037     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (45)

References (35)
  • 1
    • 33745758072 scopus 로고    scopus 로고
    • Airway and suction equipment
    • Branson RD, Hess DR, Chatburn RL, editors. Philadelphia: JB Lippincott
    • Hess D, Branson R. Airway and suction equipment. In: Branson RD, Hess DR, Chatburn RL, editors. Respiratory care equipment, 2nd ed Philadelphia: JB Lippincott: 1998: 157-186.
    • (1998) Respiratory Care Equipment, 2nd Ed , pp. 157-186
    • Hess, D.1    Branson, R.2
  • 2
    • 0012000025 scopus 로고
    • Anatomical subdivisions of the volume of the respiratory dead space and effect of position of the jaw
    • Nunn JF, Campbell EJM, Peckett BW Anatomical subdivisions of the volume of the respiratory dead space and effect of position of the jaw. J Appl Physiol 1959;14 174-176.
    • (1959) J Appl Physiol , vol.14 , pp. 174-176
    • Nunn, J.F.1    Campbell, E.J.M.2    Peckett, B.W.3
  • 5
    • 0017234033 scopus 로고
    • Aerosol penetrance: A sensitive index of peripheral airways obstruction
    • Dolovich MB, Sanchis J, Rossman C, Newhouse MT. Aerosol penetrance: a sensitive index of peripheral airways obstruction J Appl Physiol 1976;40(3):468-471.
    • (1976) J Appl Physiol , vol.40 , Issue.3 , pp. 468-471
    • Dolovich, M.B.1    Sanchis, J.2    Rossman, C.3    Newhouse, M.T.4
  • 6
    • 0018823886 scopus 로고
    • Experimental measurement and empirical modelling of the regional deposition of inhaled particles in humans
    • Chan TL, Lippmann M. Experimental measurement and empirical modelling of the regional deposition of inhaled particles in humans Am J Ind Hyg Assoc J 1980;41(6):399-409.
    • (1980) Am J Ind Hyg Assoc J , vol.41 , Issue.6 , pp. 399-409
    • Chan, T.L.1    Lippmann, M.2
  • 8
    • 0020617352 scopus 로고
    • Respiratory mechanics during halothane anesthesia and anesthesia-paralysis in humans
    • Behrakis PK, Higgs BD, Baydur A, Zin WA, Milic-Emili J. Respiratory mechanics during halothane anesthesia and anesthesia-paralysis in humans. J Appl Physiol 1983;55(4):1085-1092
    • (1983) J Appl Physiol , vol.55 , Issue.4 , pp. 1085-1092
    • Behrakis, P.K.1    Higgs, B.D.2    Baydur, A.3    Zin, W.A.4    Milic-Emili, J.5
  • 9
    • 0024394440 scopus 로고
    • In vitro versus in vivo comparison of endotracheal tube airflow resistance
    • Wright PE, Marini JJ, Bernard GR. In vitro versus in vivo comparison of endotracheal tube airflow resistance. Am Rev Respir Dis 1989;140(1):10-16.
    • (1989) Am Rev Respir Dis , vol.140 , Issue.1 , pp. 10-16
    • Wright, P.E.1    Marini, J.J.2    Bernard, G.R.3
  • 11
    • 0019377972 scopus 로고
    • Deposition of pressurized aerosols in the human respiratory tract
    • Newman SP, Pavia D, Moren F, Sheahan NF, Clarke SW. Deposition of pressurized aerosols in the human respiratory tract. Thorax 1981;36(1):52-55.
    • (1981) Thorax , vol.36 , Issue.1 , pp. 52-55
    • Newman, S.P.1    Pavia, D.2    Moren, F.3    Sheahan, N.F.4    Clarke, S.W.5
  • 12
    • 0021997262 scopus 로고
    • Fractional deposition from a jet nebulizer. How it differs from a metered-dose inhaler
    • Lewis RA, Fleming JS. Fractional deposition from a jet nebulizer. how it differs from a metered-dose inhaler. Br J Dis Chest 1985; 79(4):361-367.
    • (1985) Br J Dis Chest , vol.79 , Issue.4 , pp. 361-367
    • Lewis, R.A.1    Fleming, J.S.2
  • 13
    • 0026051588 scopus 로고
    • Aerosol consensus statement. Consensus conference on aerosol delivery
    • Aerosol consensus statement. Consensus conference on aerosol delivery. Chest 1991;100(4):1106-1109.
    • (1991) Chest , vol.100 , Issue.4 , pp. 1106-1109
  • 14
    • 0030845450 scopus 로고    scopus 로고
    • Inhaled bronchodilator therapy in mechanically ventilated patients
    • Dhand R, Tobin MJ. Inhaled bronchodilator therapy in mechanically ventilated patients. Am J Respir Crit Care Med 1997;156(1):3-10.
    • (1997) Am J Respir Crit Care Med , vol.156 , Issue.1 , pp. 3-10
    • Dhand, R.1    Tobin, M.J.2
  • 15
    • 6744223040 scopus 로고
    • Aerosol deposition to the lungs by MDI in ventilated patients: Endotracheal tubes vs tracheostomy
    • Fuller H, Dolovich M, Turpie F, Posmituck G, Wong Pack W, Newhouse M. Aerosol deposition to the lungs by MDI in ventilated patients: endotracheal tubes vs tracheostomy (abstract). Chest 1990; 98(2 Suppl):27S.
    • (1990) Chest , vol.98 , Issue.2 SUPPL.
    • Fuller, H.1    Dolovich, M.2    Turpie, F.3    Posmituck, G.4    Wong Pack, W.5    Newhouse, M.6
  • 16
    • 0022616324 scopus 로고
    • The delivery of therapeutic aerosols through endotracheal tubes
    • Ahrens RC, Ries RA, Popendorf W, Wiese JA. The delivery of therapeutic aerosols through endotracheal tubes. Pediatr Pulmonol 1986;2(1):19-26.
    • (1986) Pediatr Pulmonol , vol.2 , Issue.1 , pp. 19-26
    • Ahrens, R.C.1    Ries, R.A.2    Popendorf, W.3    Wiese, J.A.4
  • 18
    • 0030011457 scopus 로고    scopus 로고
    • Determinants of aerosolized albuterol delivery to mechanically ventilated infants
    • Coleman DM, Kelly HW, McWilliams BC. Determinants of aerosolized albuterol delivery to mechanically ventilated infants. Chest 1996;109(6):1607-1613.
    • (1996) Chest , vol.109 , Issue.6 , pp. 1607-1613
    • Coleman, D.M.1    Kelly, H.W.2    McWilliams, B.C.3
  • 19
    • 0024410061 scopus 로고
    • Delivery efficiency of metered dose aerosols given via endotracheal tubes
    • Crogan SJ, Bishop MJ. Delivery efficiency of metered dose aerosols given via endotracheal tubes. Anesthesiology 1989;70(6):1008-1010.
    • (1989) Anesthesiology , vol.70 , Issue.6 , pp. 1008-1010
    • Crogan, S.J.1    Bishop, M.J.2
  • 20
    • 0025947563 scopus 로고
    • High-efficiency delivery of salbutamol with a metered-dose inhaler in narrow tracheal tubes and catheters
    • Taylor RH, Lerman J. High-efficiency delivery of salbutamol with a metered-dose inhaler in narrow tracheal tubes and catheters. Anesthesiology 1991;74(2):360-363.
    • (1991) Anesthesiology , vol.74 , Issue.2 , pp. 360-363
    • Taylor, R.H.1    Lerman, J.2
  • 21
    • 0025174713 scopus 로고
    • Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients comparison of dose to the lungs
    • Fuller HD, Dolovich MB, Posmituck G, Pack WW, Newhouse MT. Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients comparison of dose to the lungs. Am Rev Respir Dis 1990,141(2):440-444.
    • (1990) Am Rev Respir Dis , vol.141 , Issue.2 , pp. 440-444
    • Fuller, H.D.1    Dolovich, M.B.2    Posmituck, G.3    Pack, W.W.4    Newhouse, M.T.5
  • 22
    • 85012519236 scopus 로고
    • Aerosol delivery during mechanical ventilation: A predicitve in vitro lung model
    • Fuller HD, Dolovich MB, Chambers C, Newhouse MT. Aerosol delivery during mechanical ventilation: a predicitve in vitro lung model J Aerosol Med 1992,5 251-259.
    • (1992) J Aerosol Med , vol.5 , pp. 251-259
    • Fuller, H.D.1    Dolovich, M.B.2    Chambers, C.3    Newhouse, M.T.4
  • 23
    • 0029081287 scopus 로고
    • Albuterol delivery in a model of mechanical ventilation, comparison of metered-dose inhaler and nebulizer efficiency
    • Diot P, Morra L, Smaldone GC. Albuterol delivery in a model of mechanical ventilation, comparison of metered-dose inhaler and nebulizer efficiency Am J Respir Crit Care Med 1995;152(4 pt 1):1391-1394.
    • (1995) Am J Respir Crit Care Med , vol.152 , Issue.4 PART 1 , pp. 1391-1394
    • Diot, P.1    Morra, L.2    Smaldone, G.C.3
  • 24
    • 0033022823 scopus 로고    scopus 로고
    • A comparison of bronchodilator therapy delivered by nebulization and metered-dose inhaler in mechanically ventilated patients
    • Marik P, Hogan J, Krikorian J. A comparison of bronchodilator therapy delivered by nebulization and metered-dose inhaler in mechanically ventilated patients Chest 1999;115(6):1653-1657.
    • (1999) Chest , vol.115 , Issue.6 , pp. 1653-1657
    • Marik, P.1    Hogan, J.2    Krikorian, J.3
  • 25
    • 0026782880 scopus 로고
    • Evaluation of a reservoir device for metered-dose bronchodilator delivery to intubated adults: An in vitro study
    • Rau JL, Harwood RJ, Groff JL Evaluation of a reservoir device for metered-dose bronchodilator delivery to intubated adults: an in vitro study Chest 1992,102(3):924-930
    • (1992) Chest , vol.102 , Issue.3 , pp. 924-930
    • Rau, J.L.1    Harwood, R.J.2    Groff, J.L.3
  • 26
    • 0032900977 scopus 로고    scopus 로고
    • Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors
    • Fink JB, Dhand R, Grychowski J, Fahey PJ, Tobin MJ. Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors. Am J Respir Crit Care Med 1999;159(1): 63-68.
    • (1999) Am J Respir Crit Care Med , vol.159 , Issue.1 , pp. 63-68
    • Fink, J.B.1    Dhand, R.2    Grychowski, J.3    Fahey, P.J.4    Tobin, M.J.5
  • 27
    • 0023473104 scopus 로고
    • Effects of nebulizer mode and position in a mechanical ventilator circuit on dose effciency
    • Hughes JM, Saez J. Effects of nebulizer mode and position in a mechanical ventilator circuit on dose effciency. Respir Care 1987; 32(12):1131-1135
    • (1987) Respir Care , vol.32 , Issue.12 , pp. 1131-1135
    • Hughes, J.M.1    Saez, J.2
  • 28
    • 0026728835 scopus 로고
    • Delivery of a nebulized aerosol to a lung model during mechanical ventilation: Effect of ventilator settings and nebulizer type, position, and volume of fill
    • O'Doherty MJ, Thomas SHL, Page CJ, Treacher DF, Nunan TO. Delivery of a nebulized aerosol to a lung model during mechanical ventilation: effect of ventilator settings and nebulizer type, position, and volume of fill. Am Rev Respir Dis 1992;146(2):383-388.
    • (1992) Am Rev Respir Dis , vol.146 , Issue.2 , pp. 383-388
    • O'Doherty, M.J.1    Thomas, S.H.L.2    Page, C.J.3    Treacher, D.F.4    Nunan, T.O.5
  • 30
    • 0028873969 scopus 로고
    • Effect of a spacer on pulmonary aerosol deposition-from a jet nebulizer during mechanical ventilation
    • Harvey CJ, O'Doherty MJ, Page CJ, Thomas SHL, Nunan TO, Treacher DF. Effect of a spacer on pulmonary aerosol deposition-from a jet nebulizer during mechanical ventilation Thorax 1995; 50(1):50-53.
    • (1995) Thorax , vol.50 , Issue.1 , pp. 50-53
    • Harvey, C.J.1    O'Doherty, M.J.2    Page, C.J.3    Thomas, S.H.L.4    Nunan, T.O.5    Treacher, D.F.6
  • 31
    • 0028040181 scopus 로고
    • Aerosol deposition in mechanically ventilated patients, optimizing nebulizer delivery
    • O'Riordan TG, Palmer LB, Smaldone GC. Aerosol deposition in mechanically ventilated patients, optimizing nebulizer delivery Am J Respir Crit Care Med 1994;149(1):214-219
    • (1994) Am J Respir Crit Care Med , vol.149 , Issue.1 , pp. 214-219
    • O'Riordan, T.G.1    Palmer, L.B.2    Smaldone, G.C.3
  • 32
    • 0027454256 scopus 로고
    • Delivery of ultrasonic nebulized aerosols to a lung model during mechancial ventilation
    • Thomas SHL, O'Doherty MJ, Page CJ, Treacher DF, Nunan TO. Delivery of ultrasonic nebulized aerosols to a lung model during mechancial ventilation. Am Rev Respir Dis 1993;148(4 Pt 1):872-877
    • (1993) Am Rev Respir Dis , vol.148 , Issue.4 PART 1 , pp. 872-877
    • Thomas, S.H.L.1    O'Doherty, M.J.2    Page, C.J.3    Treacher, D.F.4    Nunan, T.O.5
  • 33
    • 0030887597 scopus 로고    scopus 로고
    • Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation
    • Harvey CJ, O'Doherty MJ, Page CJ, Thomas SHL, Nunan TO, Treacher DF. Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation. Eur Respir J 1997; 10(4):905-909.
    • (1997) Eur Respir J , vol.10 , Issue.4 , pp. 905-909
    • Harvey, C.J.1    O'Doherty, M.J.2    Page, C.J.3    Thomas, S.H.L.4    Nunan, T.O.5    Treacher, D.F.6
  • 34
    • 0345050289 scopus 로고    scopus 로고
    • Heliox improves aerosol delivery from MDI during mechanical ventilation; an in vitro model
    • Fink J, Dhand R, Navin D, Fahey P, Tobin MJ. Heliox improves aerosol delivery from MDI during mechanical ventilation; an in vitro model (abstract). Am J Respir Crit Care Med 1997;155: A770.
    • (1997) Am J Respir Crit Care Med , vol.155
    • Fink, J.1    Dhand, R.2    Navin, D.3    Fahey, P.4    Tobin, M.J.5
  • 35
    • 0033027165 scopus 로고    scopus 로고
    • Bronchodilator therapy in mechanically ventilated patients
    • Fink JB, Tobin MJ, Dhand R. Bronchodilator therapy in mechanically ventilated patients. Respir Care 1999;44(1):53-69.
    • (1999) Respir Care , vol.44 , Issue.1 , pp. 53-69
    • Fink, J.B.1    Tobin, M.J.2    Dhand, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.