메뉴 건너뛰기




Volumn 46, Issue 7, 2000, Pages 989-990

Influence of hemolysis on the measurement of S-100β protein and neuron-specific enolase plasma concentrations during coronary artery bypass grafting

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN; NEURON SPECIFIC ENOLASE; PROTEIN S;

EID: 0033942105     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/46.7.989     Document Type: Article
Times cited : (59)

References (10)
  • 1
    • 0028952018 scopus 로고
    • Signs of brain cell injury during open heart operations: Past and present
    • Aberg T. Signs of brain cell injury during open heart operations: past and present. Ann Thorac Surg 1995;59:1312-5.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1312-1315
    • Aberg, T.1
  • 3
    • 0031727852 scopus 로고    scopus 로고
    • Serum and CSF levels of neuron-specific enolase (NSE) in cardiac surgery with cardiopulmonary bypass: A marker of brain injury?
    • Schmitt B, Bauersfeld U, Schmid ER, Tuchschmid P, Molinari L, Fanconi S, et al. Serum and CSF levels of neuron-specific enolase (NSE) in cardiac surgery with cardiopulmonary bypass: a marker of brain injury? Brain Dev 1998;20:536-9.
    • (1998) Brain Dev , vol.20 , pp. 536-539
    • Schmitt, B.1    Bauersfeld, U.2    Schmid, E.R.3    Tuchschmid, P.4    Molinari, L.5    Fanconi, S.6
  • 7
    • 0022457726 scopus 로고
    • Value of derivative spectrophotometry for the determination of plasma and urinary hemoglobin. Comparison with the method using Allen's correction
    • Taulier A, Levillain P, Lemonnier A. Value of derivative spectrophotometry for the determination of plasma and urinary hemoglobin. Comparison with the method using Allen's correction. Ann Biol Clin Paris 1986;44:242-8.
    • (1986) Ann Biol Clin Paris , vol.44 , pp. 242-248
    • Taulier, A.1    Levillain, P.2    Lemonnier, A.3
  • 9
    • 0030922644 scopus 로고    scopus 로고
    • Neuron-specific enolase and Sangtec 100 assays during cardiac surgery: Part III. Does haemolysis affect their accuracy?
    • Gao F, Harris DN, Sapsed-Byrne S. Neuron-specific enolase and Sangtec 100 assays during cardiac surgery: part III. Does haemolysis affect their accuracy? Perfusion 1997;12:171-7.
    • (1997) Perfusion , vol.12 , pp. 171-177
    • Gao, F.1    Harris, D.N.2    Sapsed-Byrne, S.3
  • 10
    • 0025072263 scopus 로고
    • New solid-phase enzyme immunoassay of neuron-specific enolase in serum: Effect of storage, temperature, lipemia, icterus and hemolysis
    • Mercer DW, Virji MA, Barry GE, Piper ML. New solid-phase enzyme immunoassay of neuron-specific enolase in serum: effect of storage, temperature, lipemia, icterus and hemolysis. Clin Chem 1990;36:1519.
    • (1990) Clin Chem , vol.36 , pp. 1519
    • Mercer, D.W.1    Virji, M.A.2    Barry, G.E.3    Piper, M.L.4