메뉴 건너뛰기




Volumn 24, Issue 6, 2000, Pages 446-449

Particles released from the Gyro C1E3 during simulated extracorporeal circulation

Author keywords

Centrifugal pump; Left ventricular assist device; Micro particle release; Percutaneous cardiopulmonary support; Roller pump; Spallation

Indexed keywords

FIBER OPTIC SENSORS; GYROSCOPES; LEFT VENTRICULAR ASSIST DEVICES; PUMPS; ROLLERS (MACHINE COMPONENTS);

EID: 0033932255     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.2000.06628.x     Document Type: Article
Times cited : (9)

References (14)
  • 2
    • 0020035507 scopus 로고
    • Spallation and migration of silicone from blood-pump tubing in patients on hemodialysis
    • 2. Leong AS, Disney AP, Gove DW. Spallation and migration of silicone from blood-pump tubing in patients on hemodialysis. N Engl J Med 1982;306(3):135-40.
    • (1982) N Engl J Med , vol.306 , Issue.3 , pp. 135-140
    • Leong, A.S.1    Disney, A.P.2    Gove, D.W.3
  • 4
    • 0028835332 scopus 로고
    • Centrifugal and roller pumps - Are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass?
    • 4. Steinbrueckner BE, Steigerwald U, Keller F, Neukam K, Elert O, Babin-Ebell J. Centrifugal and roller pumps - Are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass? Heart Vessels 1995;10(1): 46-53.
    • (1995) Heart Vessels , vol.10 , Issue.1 , pp. 46-53
    • Steinbrueckner, B.E.1    Steigerwald, U.2    Keller, F.3    Neukam, K.4    Elert, O.5    Babin-Ebell, J.6
  • 7
    • 0002876068 scopus 로고
    • Structural ceramics in orthopedics
    • Cameron HU, ed. St. Louis, MO: Mosby
    • 7. Clarke IC, Willmann G. Structural ceramics in orthopedics. In: Cameron HU, ed. Bone Implant Interface. St. Louis, MO: Mosby, 1994:203-52.
    • (1994) Bone Implant Interface , pp. 203-252
    • Clarke, I.C.1    Willmann, G.2
  • 10
    • 0025261061 scopus 로고
    • Particle spallation and plasticizer (DEHP) release from extracorporeal circuit tubing materials
    • 10. Hoenich NA, Thompson J, Varini E, McCabe J, Appleton D. Particle spallation and plasticizer (DEHP) release from extracorporeal circuit tubing materials. Artif Organs 1990;13(1): 55-62.
    • (1990) Artif Organs , vol.13 , Issue.1 , pp. 55-62
    • Hoenich, N.A.1    Thompson, J.2    Varini, E.3    McCabe, J.4    Appleton, D.5
  • 12
    • 0016560092 scopus 로고
    • Artificial heart. III. Development of efficient atraumatic blood pump. A review of the literature concerning in vitro testing of blood pumps for hemolysis
    • 12. Kletschka HD, Rafferty EH, Olsen DA, Clausen EW, Hubbard LC, Robinson AR, Larson WH. Artificial heart. III. Development of efficient atraumatic blood pump. A review of the literature concerning in vitro testing of blood pumps for hemolysis. Minn Med 1975;58(10):757-81.
    • (1975) Minn Med , vol.58 , Issue.10 , pp. 757-781
    • Kletschka, H.D.1    Rafferty, E.H.2    Olsen, D.A.3    Clausen, E.W.4    Hubbard, L.C.5    Robinson, A.R.6    Larson, W.H.7
  • 13
    • 0032216640 scopus 로고    scopus 로고
    • Serum S100 beta release after coronary artery bypass grafting: Roller versus centrifugal pump
    • 13. Ashraf S, Bhattacharya K, Zacharias S, Kaul P, Kay PH, Watterson KG. Serum S100 beta release after coronary artery bypass grafting: Roller versus centrifugal pump. Ann Thorac Surg 1998;66(6):1958-62.
    • (1998) Ann Thorac Surg , vol.66 , Issue.6 , pp. 1958-1962
    • Ashraf, S.1    Bhattacharya, K.2    Zacharias, S.3    Kaul, P.4    Kay, P.H.5    Watterson, K.G.6
  • 14
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surface and their effect on long-term ultra high molecular weight polyethylene wear
    • 14. Davidson JA. Characteristics of metal and ceramic total hip bearing surface and their effect on long-term ultra high molecular weight polyethylene wear. Clin Ortho 1993;294: 361-78.
    • (1993) Clin Ortho , vol.294 , pp. 361-378
    • Davidson, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.