메뉴 건너뛰기




Volumn 43, Issue 2, 2000, Pages 247-264

Can fetal-pelvic disproportion be predicted

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER ASSISTED TOMOGRAPHY; CONFERENCE PAPER; FETUS RISK; LABOR; NUCLEAR MAGNETIC RESONANCE IMAGING; PELVIMETRY; PELVIS; ULTRASOUND; VAGINAL DELIVERY;

EID: 0033923988     PISSN: 00099201     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003081-200006000-00004     Document Type: Conference Paper
Times cited : (32)

References (73)
  • 1
    • 0018902712 scopus 로고
    • Fetal response to cephalopelvic disproportion
    • Stewart KS, Philpott RH. Fetal response to cephalopelvic disproportion. Br J Obstet Gynaecol. 1980;87:641-649.
    • (1980) Br J Obstet Gynaecol , vol.87 , pp. 641-649
    • Stewart, K.S.1    Philpott, R.H.2
  • 2
    • 0029822091 scopus 로고    scopus 로고
    • Comparison of a trial of labor with an elective second cesarean section
    • McMahon MJ, Luther ER, Bowes WA, Olshan AF. Comparison of a trial of labor with an elective second cesarean section. N Engl J Med. 1996;336:689-695.
    • (1996) N Engl J Med , vol.336 , pp. 689-695
    • McMahon, M.J.1    Luther, E.R.2    Bowes, W.A.3    Olshan, A.F.4
  • 4
    • 0342796876 scopus 로고
    • Pelvicephalometry
    • Ball RP. Pelvicephalometry. Radiology. 1938;31:188-197.
    • (1938) Radiology , vol.31 , pp. 188-197
    • Ball, R.P.1
  • 5
    • 0343231465 scopus 로고
    • The clinical application of roentgen pelvimetry and a study of the results in 1,100 white women
    • Thorns H. The clinical application of roentgen pelvimetry and a study of the results in 1,100 white women. Am J Obstet Gynecol. 1941;42:957-975.
    • (1941) Am J Obstet Gynecol , vol.42 , pp. 957-975
    • Thorns, H.1
  • 6
    • 0001546678 scopus 로고
    • A practical technique for roentgen pelvimetry with a new positioning
    • Colcher AE, Sussman WA. A practical technique for roentgen pelvimetry with a new positioning. AJR Am J Roentgenol. 1944;51:207-214.
    • (1944) AJR Am J Roentgenol , vol.51 , pp. 207-214
    • Colcher, A.E.1    Sussman, W.A.2
  • 7
    • 0015375888 scopus 로고
    • A modification of the Colcher-Sussman technique of x-ray pelvimetry
    • Brown RC. A modification of the Colcher-Sussman technique of x-ray pelvimetry. AJR Am J Roentgenol. 1972;115:623-629.
    • (1972) AJR Am J Roentgenol , vol.115 , pp. 623-629
    • Brown, R.C.1
  • 8
    • 0342361986 scopus 로고
    • A simple technique and new instrument for rapid roentgen pelvimetry
    • Snow W, Lewis F. A simple technique and new instrument for rapid roentgen pelvimetry. AJR Am J Roentgenol. 1940;43: 132-137.
    • (1940) AJR Am J Roentgenol , vol.43 , pp. 132-137
    • Snow, W.1    Lewis, F.2
  • 10
    • 0001204618 scopus 로고
    • Criteria of inlet contraction. What is their value?
    • Kaltreider DF. Criteria of inlet contraction. What is their value? Am J Obstet Gynecol. 1951;62:600-606.
    • (1951) Am J Obstet Gynecol , vol.62 , pp. 600-606
    • Kaltreider, D.F.1
  • 11
    • 0019512623 scopus 로고
    • The predictability of labor outcome from a comparison of birth weight and x-ray pelvimetry
    • Jagani N, Schulman H, Chandra P, Gonzalez R, Fleischer A. The predictability of labor outcome from a comparison of birth weight and x-ray pelvimetry. Am J Obstet Gynecol. 1981;139:507-511.
    • (1981) Am J Obstet Gynecol , vol.139 , pp. 507-511
    • Jagani, N.1    Schulman, H.2    Chandra, P.3    Gonzalez, R.4    Fleischer, A.5
  • 12
    • 0001045648 scopus 로고
    • Estimation of pelvic capacity
    • Mengert WF. Estimation of pelvic capacity. JAMA. 1948;138:169-174.
    • (1948) JAMA , vol.138 , pp. 169-174
    • Mengert, W.F.1
  • 13
    • 0022518252 scopus 로고
    • The fetal-pelvic index as an indicator of fetal-pelvic disproportion: A preliminary report
    • Morgan MA, Thurnau GR, Fishburne JI. The fetal-pelvic index as an indicator of fetal-pelvic disproportion: A preliminary report. Am J Obstet Gynecol. 1986;155: 608-613.
    • (1986) Am J Obstet Gynecol , vol.155 , pp. 608-613
    • Morgan, M.A.1    Thurnau, G.R.2    Fishburne, J.I.3
  • 15
    • 77049279645 scopus 로고
    • Correlation of cephalopelvimetry to obstetrical outcome with special reference to radiologic disproportion
    • Schwartz GS, Kirkpatrick RH, Tovell HMM. Correlation of cephalopelvimetry to obstetrical outcome with special reference to radiologic disproportion. Radiology. 1956;67:854-862.
    • (1956) Radiology , vol.67 , pp. 854-862
    • Schwartz, G.S.1    Kirkpatrick, R.H.2    Tovell, H.M.M.3
  • 16
    • 0342796874 scopus 로고
    • X-ray pelvimetry and the outcome of labor
    • Steer CM. X-ray pelvimetry and the outcome of labor. Am J Obstet Gynecol. 1958; 76:118-131.
    • (1958) Am J Obstet Gynecol , vol.76 , pp. 118-131
    • Steer, C.M.1
  • 17
    • 0343667130 scopus 로고
    • Criteria of midplane contraction: What is their value?
    • Kaltreider DF. Criteria of midplane contraction: What is their value? Am J Obstet Gynecol. 1952;63:393-399.
    • (1952) Am J Obstet Gynecol , vol.63 , pp. 393-399
    • Kaltreider, D.F.1
  • 18
    • 0342361985 scopus 로고
    • The prediction and management of outlet dystocia
    • Kaltreider DF. The prediction and management of outlet dystocia. Am J Obstet Gynecol. 1954;67:1049-1066.
    • (1954) Am J Obstet Gynecol , vol.67 , pp. 1049-1066
    • Kaltreider, D.F.1
  • 20
    • 0016826409 scopus 로고
    • Role of pelvimetry in active management of labor
    • Joyce DN, Giwa-Osagi F, Stevenson GW. Role of pelvimetry in active management of labor. BMJ. 1975;4:505-507.
    • (1975) BMJ , vol.4 , pp. 505-507
    • Joyce, D.N.1    Giwa-Osagi, F.2    Stevenson, G.W.3
  • 21
    • 0019278185 scopus 로고
    • Radiologic low-dose pelvimetry: Indications and pelvimetry data
    • Ohlsen H. Radiologic Low-dose pelvimetry: Indications and pelvimetry data. Acta Radiol. 1980;21:747-758.
    • (1980) Acta Radiol , vol.21 , pp. 747-758
    • Ohlsen, H.1
  • 23
    • 0018857223 scopus 로고
    • An evaluation of the usefulness of x-ray pelvimetry: Comparison of the Thorns and modified ball methods with manual pelvimetry
    • Fine EA, Bracken M, Berkowitz RL. An evaluation of the usefulness of x-ray pelvimetry: Comparison of the Thorns and modified Ball methods with manual pelvimetry. Am J Obstet Gynecol. 1980;137: 15-20.
    • (1980) Am J Obstet Gynecol , vol.137 , pp. 15-20
    • Fine, E.A.1    Bracken, M.2    Berkowitz, R.L.3
  • 24
    • 0019481573 scopus 로고
    • A prospective evaluation of x-ray pelvimetry
    • Laube DW, Varner MW, Cruikshank DP. A prospective evaluation of x-ray pelvimetry. JAMA. 1981;246:2187-2188.
    • (1981) JAMA , vol.246 , pp. 2187-2188
    • Laube, D.W.1    Varner, M.W.2    Cruikshank, D.P.3
  • 27
    • 0025727148 scopus 로고
    • The cephalopelvic disproportion index. Combined fetal sonography and x-ray pelvimetry for early detection of cephalopelvic disproportion
    • Abitbol MM, Taylor UB, Castillo I, Rochelson BL. The cephalopelvic disproportion index. Combined fetal sonography and x-ray pelvimetry for early detection of cephalopelvic disproportion. J Reprod Med. 1991;36:369-373.
    • (1991) J Reprod Med , vol.36 , pp. 369-373
    • Abitbol, M.M.1    Taylor, U.B.2    Castillo, I.3    Rochelson, B.L.4
  • 28
    • 0023878177 scopus 로고
    • Efficacy of the fetal-pelvic index,for delivery of neonates weighing 4,000 grams or greater
    • Morgan MA, Thurnau GR. Efficacy of the fetal-pelvic index,for delivery of neonates weighing 4,000 grams or greater. Am J Obstet Gynecol. 1988;158:1133-1137.
    • (1988) Am J Obstet Gynecol , vol.158 , pp. 1133-1137
    • Morgan, M.A.1    Thurnau, G.R.2
  • 29
    • 0023677925 scopus 로고
    • Efficacy of the fetal-pelvic index in patients requiring labor induction
    • Morgan MA, Thurnau GR. Efficacy of the fetal-pelvic index in patients requiring labor induction. Am J Obstet Gynecol. 1988; 159:621-625.
    • (1988) Am J Obstet Gynecol , vol.159 , pp. 621-625
    • Morgan, M.A.1    Thurnau, G.R.2
  • 30
    • 0024261639 scopus 로고
    • Efficacy of the fetal-pelvic index as a predictor of fetal-pelvic disproportion in patients with abnormal labor patterns requiring labor augmentations
    • Thurnau GR, Morgan MA. Efficacy of the fetal-pelvic index as a predictor of fetal-pelvic disproportion in patients with abnormal labor patterns requiring labor augmentations. Am J Obstet Gynecol. 1988;159: 1168-1172.
    • (1988) Am J Obstet Gynecol , vol.159 , pp. 1168-1172
    • Thurnau, G.R.1    Morgan, M.A.2
  • 31
    • 0025783726 scopus 로고
    • The fetal-pelvic index: A method of identifying fetal-pelvic disproportion in women attempting vaginal birth after previous Cesarean delivery
    • Thurnau GR, Scales DH, Morgan MA. The fetal-pelvic index: A method of identifying fetal-pelvic disproportion in women attempting vaginal birth after previous Cesarean delivery. Am J Obstet Gynecol. 1991; 165:353-358.
    • (1991) Am J Obstet Gynecol , vol.165 , pp. 353-358
    • Thurnau, G.R.1    Scales, D.H.2    Morgan, M.A.3
  • 32
    • 0026535711 scopus 로고
    • Efficacy of the fetal-pelvic index in nulliparous women at high risk for fetal-pelvic disproportion
    • Morgan MA, Thurnau GR. Efficacy of the fetal-pelvic index in nulliparous women at high risk for fetal-pelvic disproportion. Am J Obstet Gynecol. 1992;166:810-814.
    • (1992) Am J Obstet Gynecol , vol.166 , pp. 810-814
    • Morgan, M.A.1    Thurnau, G.R.2
  • 36
    • 0022995560 scopus 로고
    • Computed tomographic pelvimetry
    • Lenke RR, Shuman WP. Computed tomographic pelvimetry. J Reprod Med. 1986; 31:958-960.
    • (1986) J Reprod Med , vol.31 , pp. 958-960
    • Lenke, R.R.1    Shuman, W.P.2
  • 38
    • 0024515045 scopus 로고
    • Fetal dose estimates for CT pelvimetry
    • Moore MM, Shearer DR. Fetal dose estimates for CT pelvimetry. Radiology. 1989; 171:256-267.
    • (1989) Radiology , vol.171 , pp. 256-267
    • Moore, M.M.1    Shearer, D.R.2
  • 40
    • 0026072206 scopus 로고
    • Improving the accuracy of digital CT pelvimetry
    • Smith RC, McCarthy S. Improving the accuracy of digital CT pelvimetry. J Comput Assist Tomogr. 1991;15:787-789.
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 787-789
    • Smith, R.C.1    McCarthy, S.2
  • 42
    • 0026601260 scopus 로고
    • Accuracy of pelvimetry measurements on CT scanners
    • Wade JP. Accuracy of pelvimetry measurements on CT scanners. Br J Radiol. 1992; 65:261-263.
    • (1992) Br J Radiol , vol.65 , pp. 261-263
    • Wade, J.P.1
  • 43
    • 0022374427 scopus 로고
    • X-ray pelvimetry in a breech protocol: A comparison of digital radiography and conventional methods
    • Gimovsky ML, Willard K, Neglio M, Howard T, Zerne S. X-ray pelvimetry in a breech protocol: A comparison of digital radiography and conventional methods. Am J Obstet Gynecol. 1985;153:887-888.
    • (1985) Am J Obstet Gynecol , vol.153 , pp. 887-888
    • Gimovsky, M.L.1    Willard, K.2    Neglio, M.3    Howard, T.4    Zerne, S.5
  • 44
    • 0027238207 scopus 로고
    • Computed tomography pelvimetry: Accuracy and radiation dose compared with conventional pelvimetry
    • Morris CW, Heggie JCP, Action CM. Computed tomography pelvimetry: Accuracy and radiation dose compared with conventional pelvimetry. Australas Radiol. 1993;37:186-191.
    • (1993) Australas Radiol , vol.37 , pp. 186-191
    • Morris, C.W.1    Heggie, J.C.P.2    Action, C.M.3
  • 45
    • 84984088057 scopus 로고
    • The accuracy and value of cephalopelvimetry
    • Crichton D. The accuracy and value of cephalopelvimetry. Br J Obstet Gynecol. 1962;69:366-378.
    • (1962) Br J Obstet Gynecol , vol.69 , pp. 366-378
    • Crichton, D.1
  • 46
    • 0020025464 scopus 로고
    • The efficacy of x-ray pelvimetry [Discussion follows article]
    • Barton JJ, Garbaciak JA, Ryan GM. The efficacy of x-ray pelvimetry [Discussion follows article]. Am J Obstet Gynecol. 1982;143:304-307.
    • (1982) Am J Obstet Gynecol , vol.143 , pp. 304-307
    • Barton, J.J.1    Garbaciak, J.A.2    Ryan, G.M.3
  • 47
    • 0021852901 scopus 로고
    • Prospective randomized study of x-ray pelvimetry in the primagravida
    • Parsons MT, Spellacy WN. Prospective randomized study of x-ray pelvimetry in the primagravida. Obstet Gynecol. 1985; 66:76-79.
    • (1985) Obstet Gynecol , vol.66 , pp. 76-79
    • Parsons, M.T.1    Spellacy, W.N.2
  • 50
    • 0021135219 scopus 로고
    • The changing place of radiology in obstetrics
    • Gordon A, Pinchen C, Walker E, Tudor J. The changing place of radiology in obstetrics. Br J Radiol. 1984;57:891-893.
    • (1984) Br J Radiol , vol.57 , pp. 891-893
    • Gordon, A.1    Pinchen, C.2    Walker, E.3    Tudor, J.4
  • 51
    • 0031938096 scopus 로고    scopus 로고
    • Trends in the use of pelvimetry techniques
    • Thomas SM, Bees NR, Adam EJ. Trends in the use of pelvimetry techniques (see comments). Clin Radiol. 1998;53:293-295.
    • (1998) Clin Radiol , vol.53 , pp. 293-295
    • Thomas, S.M.1    Bees, N.R.2    Adam, E.J.3
  • 53
    • 0020077556 scopus 로고
    • An evaluation of two equations for predicting fetal weight by ultrasound
    • Shepard MJ, Richards VA, Berkowitz FL, et al. An evaluation of two equations for predicting fetal weight by ultrasound. Am J Obstet Gynecol. 1982;142:47-54.
    • (1982) Am J Obstet Gynecol , vol.142 , pp. 47-54
    • Shepard, M.J.1    Richards, V.A.2    Berkowitz, F.L.3
  • 54
    • 0021339720 scopus 로고
    • Sonographic estimation of fetal weight: The value of femur length in addition to head and abdomen measurements
    • Hadlock FP, Harrist RB, Carpenter RJ, et al. Sonographic estimation of fetal weight: The value of femur length in addition to head and abdomen measurements. Radiology. 1984;150:535-540.
    • (1984) Radiology , vol.150 , pp. 535-540
    • Hadlock, F.P.1    Harrist, R.B.2    Carpenter, R.J.3
  • 56
    • 0020483474 scopus 로고
    • Cesarean delivery in nulliparous women for failed oxytocin-augmented labor: Route of delivery in subsequent pregnancy
    • Seitchik J, Rao VR. Cesarean delivery in nulliparous women for failed oxytocin-augmented labor: Route of delivery in subsequent pregnancy. Am J Obstet Gynecol. 1982;143:393-397.
    • (1982) Am J Obstet Gynecol , vol.143 , pp. 393-397
    • Seitchik, J.1    Rao, V.R.2
  • 58
    • 0033061423 scopus 로고    scopus 로고
    • Measurement of obstetric conjugate by ultrasonic tomography and its significance
    • Katanozaka M, Yoshinaga M, Fuchiwaki K, Nagata Y. Measurement of obstetric conjugate by ultrasonic tomography and its significance. Am J Obstet Gynecol. 1999; 180:159-162.
    • (1999) Am J Obstet Gynecol , vol.180 , pp. 159-162
    • Katanozaka, M.1    Yoshinaga, M.2    Fuchiwaki, K.3    Nagata, Y.4
  • 59
    • 0023626639 scopus 로고
    • Vaginosono-graphical determination of the true conjugate and the transverse diameter of the pelvic inlet
    • Deutinger J, Bernaschek G. Vaginosono-graphical determination of the true conjugate and the transverse diameter of the pelvic inlet. Arch Gynecol. 1987;240:241-246.
    • (1987) Arch Gynecol , vol.240 , pp. 241-246
    • Deutinger, J.1    Bernaschek, G.2
  • 60
    • 0015550666 scopus 로고
    • A method of measuring the interspinous diameter by an ultrasonic technique
    • Vaclavinkova V. A method of measuring the interspinous diameter by an ultrasonic technique. Acta Obstet Gynecol Scand. 1973;52:161-165.
    • (1973) Acta Obstet Gynecol Scand , vol.52 , pp. 161-165
    • Vaclavinkova, V.1
  • 64
    • 0026761850 scopus 로고
    • Magnetic resonance imaging pelvimetry: A useful adjunct in the management of the obese patient
    • Wright AR, Cameron HM, Lind T. Magnetic resonance imaging pelvimetry: A useful adjunct in the management of the obese patient. Br J Obstet Gynaecol. 1992;99:852-853.
    • (1992) Br J Obstet Gynaecol , vol.99 , pp. 852-853
    • Wright, A.R.1    Cameron, H.M.2    Lind, T.3
  • 65
    • 0343683351 scopus 로고    scopus 로고
    • Pelvimetry by magnetic resonance imaging as a diagnostic tool to evaluate dystocia
    • Sporri S, Hanggi W, Braghetti A, Bock P, Schneider H. Pelvimetry by magnetic resonance imaging as a diagnostic tool to evaluate dystocia. Obstet Gynecol. 1997;89:902-908.
    • (1997) Obstet Gynecol , vol.89 , pp. 902-908
    • Sporri, S.1    Hanggi, W.2    Braghetti, A.3    Bock, P.4    Schneider, H.5
  • 67
    • 0026144640 scopus 로고
    • A technique of magnetic resonance tomographic pelvimetry in obstetrics. TT - Technik der kernspintomographischen beckenmessung in der geburtshilfe
    • Sigmund G, Bauer M, Henne K, DeGregorio G, Wenz W. A technique of magnetic resonance tomographic pelvimetry in obstetrics. TT - Technik der kernspintomographischen Beckenmessung in der Geburtshilfe. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 1991;154:370-374.
    • (1991) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.154 , pp. 370-374
    • Sigmund, G.1    Bauer, M.2    Henne, K.3    DeGregorio, G.4    Wenz, W.5
  • 68
    • 0026068144 scopus 로고
    • Ultrafast pelvimetry using Snapshot-FLASH-MRT: A comparison with the Spinecho and FLASH techniques. TT-ultraschnelle Pelvimetrie mittels Snapshot-FLASH-MRT-Vergleich mit der Spinecho-und FLASH-Technik
    • Urhahn R, Lehnen H, Drobnitzky M, Klose KC, Gunther RW. Ultrafast pelvimetry using Snapshot-FLASH-MRT: A comparison with the Spinecho and FLASH techniques. TT-Ultraschnelle Pelvimetrie mittels Snapshot-FLASH-MRT-Vergleich mit der Spinecho-und FLASH-Technik. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 1991;155:432-435.
    • (1991) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.155 , pp. 432-435
    • Urhahn, R.1    Lehnen, H.2    Drobnitzky, M.3    Klose, K.C.4    Gunther, R.W.5
  • 69
  • 73
    • 0029078696 scopus 로고
    • The prevention of mechanical birth trauma by means of computer aided simulation of delivery by means of nuclear magnetic resonance imaging and finite element analysis
    • Melchert F, Wischnik A, Nalepa E. The prevention of mechanical birth trauma by means of computer aided simulation of delivery by means of nuclear magnetic resonance imaging and finite element analysis. Br J Obstet Gynaecol. 1995;21: 195-207.
    • (1995) Br J Obstet Gynaecol , vol.21 , pp. 195-207
    • Melchert, F.1    Wischnik, A.2    Nalepa, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.