메뉴 건너뛰기




Volumn 96, Issue 2, 2000, Pages 157-161

Fetal weight prediction by thigh volume measurement with three-dimensional ultrasonography

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BIPARIETAL DISTANCE; BIRTH WEIGHT; CONTROLLED STUDY; FEMALE; FEMUR; FETUS; FETUS GROWTH; FETUS WEIGHT; HUMAN; MAJOR CLINICAL STUDY; MALE; PREDICTION; PRIORITY JOURNAL; ULTRASOUND;

EID: 0033923723     PISSN: 00297844     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0029-7844(00)00884-X     Document Type: Article
Times cited : (50)

References (15)
  • 1
    • 0015065171 scopus 로고
    • Predicting fetal weight by ultrasound B-scan cephalometry: An improved technique with disappointing results
    • Ianniruberto A., Gibbons J.M. Predicting fetal weight by ultrasound B-scan cephalometry An improved technique with disappointing results . Obstet Gynecol. 37:1971;689-694.
    • (1971) Obstet Gynecol , vol.37 , pp. 689-694
    • Ianniruberto, A.1    Gibbons, J.M.2
  • 2
    • 0345507466 scopus 로고
    • Ultrasonic measurement of the fetal abdominal circumference in estimation of fetal weight
    • Campbell S., Wilkin D. Ultrasonic measurement of the fetal abdominal circumference in estimation of fetal weight. Br J Obstet Gynaecol. 82:1975;689-697.
    • (1975) Br J Obstet Gynaecol , vol.82 , pp. 689-697
    • Campbell, S.1    Wilkin, D.2
  • 5
    • 0021339720 scopus 로고
    • Sonographic estimation of fetal weight. The value of femur length in addition to head and abdomen measurements
    • Hadlock F.P., Harrist R.B., Carpenter R.J., Deter R.L., Oark S.K. Sonographic estimation of fetal weight. The value of femur length in addition to head and abdomen measurements. Radiology. 150:1984;535-540.
    • (1984) Radiology , vol.150 , pp. 535-540
    • Hadlock, F.P.1    Harrist, R.B.2    Carpenter, R.J.3    Deter, R.L.4    Oark, S.K.5
  • 6
    • 0022622719 scopus 로고
    • Comparison of fetal weight estimation formulas with and without head measurements
    • Warsof S.L., Wolf P., Coulehan J., Queenam T.J. Comparison of fetal weight estimation formulas with and without head measurements. Obstet Gynecol. 67:1986;569-573.
    • (1986) Obstet Gynecol , vol.67 , pp. 569-573
    • Warsof, S.L.1    Wolf, P.2    Coulehan, J.3    Queenam, T.J.4
  • 8
    • 0029348107 scopus 로고
    • Prospective study on fetal weight estimation using limb circumferences obtained by three-dimensional ultrasound
    • Favre R., Bader A.M., Nisand G. Prospective study on fetal weight estimation using limb circumferences obtained by three-dimensional ultrasound. Ultrasound Obstet Gynecol. 6:1995;140-144.
    • (1995) Ultrasound Obstet Gynecol , vol.6 , pp. 140-144
    • Favre, R.1    Bader, A.M.2    Nisand, G.3
  • 9
    • 0030806030 scopus 로고    scopus 로고
    • Predicting birth weight by fetal upper arm volume using three-dimensional ultrasound
    • Liang R.I., Chang F.M., Yao B.L., Chang C.H., Yu C.H., Ko H.C. Predicting birth weight by fetal upper arm volume using three-dimensional ultrasound. Am J Obstet Gynecol. 177:1997;632-638.
    • (1997) Am J Obstet Gynecol , vol.177 , pp. 632-638
    • Liang, R.I.1    Chang, F.M.2    Yao, B.L.3    Chang, C.H.4    Yu, C.H.5    Ko, H.C.6
  • 10
    • 0030829383 scopus 로고    scopus 로고
    • Three-dimensional ultrasound-assessed fetal thigh volumetry in predicting birth weight
    • Chang F.M., Liang R.I., Ko H.C., Yao B.L., Chang C.H., Yu C.H. Three-dimensional ultrasound-assessed fetal thigh volumetry in predicting birth weight. Obstet Gynecol. 90:1997;331-339.
    • (1997) Obstet Gynecol , vol.90 , pp. 331-339
    • Chang, F.M.1    Liang, R.I.2    Ko, H.C.3    Yao, B.L.4    Chang, C.H.5    Yu, C.H.6
  • 11
    • 0021833020 scopus 로고
    • Fetal limb volume: A new parameter to assess fetal growth and nutrition
    • Jeanty P., Romero R., Hobbins J.C. Fetal limb volume A new parameter to assess fetal growth and nutrition . J Ultrasound Med. 4:1985;273-282.
    • (1985) J Ultrasound Med , vol.4 , pp. 273-282
    • Jeanty, P.1    Romero, R.2    Hobbins, J.C.3
  • 12
    • 0030043484 scopus 로고    scopus 로고
    • Transvaginal three-dimensional ultrasound: Accuracy of follicular volume measurements
    • Kyei-Mensah A., Zaidi J., Pittrof R., Shaker A., Campbell S., Tan S.L. Transvaginal three-dimensional ultrasound Accuracy of follicular volume measurements . Fertil Steril. 65:1996;371-376.
    • (1996) Fertil Steril , vol.65 , pp. 371-376
    • Kyei-Mensah, A.1    Zaidi, J.2    Pittrof, R.3    Shaker, A.4    Campbell, S.5    Tan, S.L.6
  • 13
    • 0030249428 scopus 로고    scopus 로고
    • In vivo three-dimensional sonographic measurement of organ volume validation in urinary bladder
    • Riccabona M., Nelson T.R., Pretorius D.H., Davidson T.E. In vivo three-dimensional sonographic measurement of organ volume validation in urinary bladder. J Ultrasound Med. 15:1996;627-632.
    • (1996) J Ultrasound Med , vol.15 , pp. 627-632
    • Riccabona, M.1    Nelson, T.R.2    Pretorius, D.H.3    Davidson, T.E.4
  • 14
    • 0029812979 scopus 로고    scopus 로고
    • Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography: A comparison with radionucleotide angiography
    • Nosir T.F.M., Fioretti P.M., Vletter W.B., Boersma E., Salustri A., Postma J.T., et al. Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography A comparison with radionucleotide angiography . Circulation. 94:1996;460-466.
    • (1996) Circulation , vol.94 , pp. 460-466
    • Nosir, T.F.M.1    Fioretti, P.M.2    Vletter, W.B.3    Boersma, E.4    Salustri, A.5    Postma, J.T.6
  • 15
    • 0026065475 scopus 로고
    • Evaluation of in vitro measurement accuracy of a three-dimensional ultrasound scanner
    • King D.L., King D.L. Jr, Shao M.Y.C. Evaluation of in vitro measurement accuracy of a three-dimensional ultrasound scanner. J Ultrasound Med. 10:1991;77-82.
    • (1991) J Ultrasound Med , vol.10 , pp. 77-82
    • King, D.L.1    King D.L., Jr.2    Shao, M.Y.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.