메뉴 건너뛰기




Volumn 17, Issue 5, 2000, Pages 457-461

Assessment of myocardial perfusion by power contrast imaging using a new echo contrast agent

Author keywords

Myocardial contrast echocardiography; Myocardial perfusion; Power contrast imaging; Transthoracic echocardiography

Indexed keywords

ECHO CONTRAST MEDIUM; METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M; SONOVUE;

EID: 0033913405     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2000.tb01165.x     Document Type: Article
Times cited : (5)

References (21)
  • 1
    • 17144444200 scopus 로고    scopus 로고
    • Usefulness of combined color Doppler/contrast in providing complete delineation of left ventricular cavity
    • 1. Agrawal G, Cape EG, Raichlen JS, et al: Usefulness of combined color Doppler/contrast in providing complete delineation of left ventricular cavity. Am J Cardiol 1997;80:98-101.
    • (1997) Am J Cardiol , vol.80 , pp. 98-101
    • Agrawal, G.1    Cape, E.G.2    Raichlen, J.S.3
  • 2
    • 0030792911 scopus 로고    scopus 로고
    • Detection of coronary artery disease with myocardial contrast echocardiography: Comparison with Tc-99m sestamibi, single-photon emission computed tomography
    • 2. Kaul S, Senior R, Dittrich H, et al: Detection of coronary artery disease with myocardial contrast echocardiography: Comparison with Tc-99m sestamibi, single-photon emission computed tomography. Circulation 1997;93:785-792.
    • (1997) Circulation , vol.93 , pp. 785-792
    • Kaul, S.1    Senior, R.2    Dittrich, H.3
  • 3
    • 0030226472 scopus 로고    scopus 로고
    • Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging
    • 3. Porter TR, Xie F, Li S, et al: Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging. J Acoust Soc Am 1996;9:599-605.
    • (1996) J Acoust Soc Am , vol.9 , pp. 599-605
    • Porter, T.R.1    Xie, F.2    Li, S.3
  • 4
    • 0031439631 scopus 로고    scopus 로고
    • Harmonic power Doppler contrast echocardiography: Preliminary experimental results
    • 4. Agrawal DI, Malhotra S, Nanda NC, et al: Harmonic power Doppler contrast echocardiography: Preliminary experimental results. Echocardiography 1997; 14:631-635.
    • (1997) Echocardiography , vol.14 , pp. 631-635
    • Agrawal, D.I.1    Malhotra, S.2    Nanda, N.C.3
  • 5
    • 0031466459 scopus 로고    scopus 로고
    • Harmonic power Doppler contrast echocardiography: Preliminary clinical results
    • 5. Becher H, Tiemann K, Schlief R, et al: Harmonic power Doppler contrast echocardiography: Preliminary clinical results. Echocardiography 1997; 14:637-642.
    • (1997) Echocardiography , vol.14 , pp. 637-642
    • Becher, H.1    Tiemann, K.2    Schlief, R.3
  • 6
    • 0031818262 scopus 로고    scopus 로고
    • Improvement of endocardial border delineation using tissue harmonic imaging
    • 6. Becher H, Tiemann K, Schlosser T, et al: Improvement of endocardial border delineation using tissue harmonic imaging. Echocardiography 1998;15-.511-517.
    • (1998) Echocardiography , vol.15 , pp. 511-517
    • Becher, H.1    Tiemann, K.2    Schlosser, T.3
  • 7
    • 0026100487 scopus 로고
    • Influence of various instrument settings on the flow information derived from the power mode
    • 7. Jain SP, Fan PH, Philpot EF, et al: Influence of various instrument settings on the flow information derived from the power mode. Ultrasound Med Biol 1991;17:49-54.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 49-54
    • Jain, S.P.1    Fan, P.H.2    Philpot, E.F.3
  • 8
    • 0026008763 scopus 로고
    • Amplitude information from color Doppler: A preliminary study of the power mode
    • 8. Parro A, Philpot EF, Czuwala P, et al: Amplitude information from color Doppler: A preliminary study of the power mode. J Am Coll Cardiol 1991;18:997-1003.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 997-1003
    • Parro, A.1    Philpot, E.F.2    Czuwala, P.3
  • 9
    • 0032714578 scopus 로고    scopus 로고
    • Real-time contrast echo assessment of myocardial perfusion at low emission power: First experimental and clinical results using power pulse inversion imaging
    • 9. Tiemann K, Lohmeier S, Kuntz S, et al: Real-time contrast echo assessment of myocardial perfusion at low emission power: First experimental and clinical results using power pulse inversion imaging. Echocardiography 1999;6:799-809.
    • (1999) Echocardiography , vol.6 , pp. 799-809
    • Tiemann, K.1    Lohmeier, S.2    Kuntz, S.3
  • 10
    • 0033978497 scopus 로고    scopus 로고
    • Are microbubbles free flowing tracers through the myocardium? comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging
    • 10. Tiemann K, Schlosser T, Pohl C, et al: Are microbubbles free flowing tracers through the myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging. Echocardiography 2000;17:197-200.
    • (2000) Echocardiography , vol.17 , pp. 197-200
    • Tiemann, K.1    Schlosser, T.2    Pohl, C.3
  • 11
    • 0030943213 scopus 로고    scopus 로고
    • Stimulated acoustic emission: Nonbackscatter contrast effect of microbubbles seen with harmonic power Doppler imaging
    • 11. Tiemann K, Becher H, Bimmel D, et al: Stimulated acoustic emission: Nonbackscatter contrast effect of microbubbles seen with harmonic power Doppler imaging. Echocardiography 1997;14:65-69.
    • (1997) Echocardiography , vol.14 , pp. 65-69
    • Tiemann, K.1    Becher, H.2    Bimmel, D.3
  • 12
    • 0030811703 scopus 로고    scopus 로고
    • Coronary and myocardial blood volumes: Noninvasive tools to assess the coronary microcirculation?
    • Editorial; Comment
    • 12. Kaul S, Jayaweera AR: Coronary and myocardial blood volumes: Noninvasive tools to assess the coronary microcirculation? Circulation 1997;96:719-724. Editorial; Comment.
    • (1997) Circulation , vol.96 , pp. 719-724
    • Kaul, S.1    Jayaweera, A.R.2
  • 13
    • 0033009439 scopus 로고    scopus 로고
    • Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging
    • 13. Porter TR, Li S, Jiang L, et al: Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging. J Am Soc Echocardiogr 1999;12:266-271.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 266-271
    • Porter, T.R.1    Li, S.2    Jiang, L.3
  • 14
    • 0033096935 scopus 로고    scopus 로고
    • Pulse Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents
    • 14. Hope Simpson D, Chin CT, Burns PN: Pulse Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents. IEEE Trans Untrason Ferroelectr Freq Control 1999;46:372-382.
    • (1999) IEEE Trans Untrason Ferroelectr Freq Control , vol.46 , pp. 372-382
    • Hope Simpson, D.1    Chin, C.T.2    Burns, P.N.3
  • 15
    • 0026557769 scopus 로고
    • Successful and reproducible myocardial opacification during two-dimensional echocardiography from right heart injection of contrast
    • 15. Villanueva FS, Glasheen WP, Sklenar J, et al: Successful and reproducible myocardial opacification during two-dimensional echocardiography from right heart injection of contrast. Circulation 1992;85:1557-1564.
    • (1992) Circulation , vol.85 , pp. 1557-1564
    • Villanueva, F.S.1    Glasheen, W.P.2    Sklenar, J.3
  • 16
    • 0030059706 scopus 로고    scopus 로고
    • Harmonic imaging with ultrasound contrast agents
    • 16. Burns PN: Harmonic imaging with ultrasound contrast agents. Clin Radiol 1996;51(suppl 1):50-55.
    • (1996) Clin Radiol , vol.51 , Issue.SUPPL. 1 , pp. 50-55
    • Burns, P.N.1
  • 17
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • 17. Wei K, Jayaweera AR, Firoozan S, et al: Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998;97:473-483.
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3
  • 18
    • 0032828260 scopus 로고    scopus 로고
    • The crossroads of contrast echocardiography: Overview
    • 18. Nanda NC: The crossroads of contrast echocardiography: Overview. Echocardiography 1999;16:731-732.
    • (1999) Echocardiography , vol.16 , pp. 731-732
    • Nanda, N.C.1
  • 20
    • 0001142349 scopus 로고    scopus 로고
    • Echo-enhancing agents: Safety
    • Nanda NC, Schlief R, Goldberg BB (eds): Dordrecht, The Netherlands, Kluwer Academic Publishers
    • 20. Nanda NC, Carstensen EL: Echo-enhancing agents: Safety. In: Nanda NC, Schlief R, Goldberg BB (eds): Advances in Echo Imaging Using Contrast Enhancement, 2nd ed. Dordrecht, The Netherlands, Kluwer Academic Publishers, 1997, pp. 115-131.
    • (1997) Advances in Echo Imaging Using Contrast Enhancement, 2nd Ed. , pp. 115-131
    • Nanda, N.C.1    Carstensen, E.L.2
  • 21
    • 0032830282 scopus 로고    scopus 로고
    • Characteristics of SonoVue
    • 21. Schneider M: Characteristics of SonoVue. Echocardiography 1999;16:743-746.
    • (1999) Echocardiography , vol.16 , pp. 743-746
    • Schneider, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.