메뉴 건너뛰기




Volumn 42, Issue 1, 2000, Pages 10-13

Non-contact ultrasound and wireless telemetry - a step forward in remote NDT

Author keywords

[No Author keywords available]

Indexed keywords

NON-CONTACT ULTRASONIC SENSORS; WIRELESS TELEMETRY;

EID: 0033896866     PISSN: 13542575     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (10)
  • 2
    • 0032155194 scopus 로고    scopus 로고
    • A Low-Cost High-Definition Wireless Sensor System Utilizing Intersymbol Interference
    • A Pohl, 'A Low-Cost High-Definition Wireless Sensor System Utilizing Intersymbol Interference', IEEE Trans. Ultrason. Ferroelect. Freq. Cont., Vol 45, No 5, pp 1355-1362, 1998.
    • (1998) IEEE Trans. Ultrason. Ferroelect. Freq. Cont. , vol.45 , Issue.5 , pp. 1355-1362
    • Pohl, A.1
  • 3
    • 0032154782 scopus 로고    scopus 로고
    • Wireless Sensing Using Oscillator Circuits Locked to Remote High-Q SAW Resonators
    • A Pohl, G Ostermayer and F Seifert, 'Wireless Sensing Using Oscillator Circuits Locked to Remote High-Q SAW Resonators', IEEE Trans. Ultrason. Ferroelect. Freq. Cont., Vol 45, No 5, pp 1161-1168, 1998.
    • (1998) IEEE Trans. Ultrason. Ferroelect. Freq. Cont. , vol.45 , Issue.5 , pp. 1161-1168
    • Pohl, A.1    Ostermayer, G.2    Seifert, F.3
  • 4
    • 0025698113 scopus 로고
    • Passive Wireless Actuator Control and Sensor Signal Transmission
    • P A Neukomm and H Kundig, 'Passive Wireless Actuator Control and Sensor Signal Transmission', Sensors and Actuators A - Physical, A21-23, pp 258-262, 1990.
    • (1990) Sensors and Actuators A - Physical , vol.A21-23 , pp. 258-262
    • Neukomm, P.A.1    Kundig, H.2
  • 5
    • 0032123869 scopus 로고    scopus 로고
    • A 0.5-mW Passive Telemetry System for Biomedical Applications
    • Q Huang and M Oberle, 'A 0.5-mW Passive Telemetry System for Biomedical Applications', IEEE J. Solid State Circuits, Vol 33, No 7, pp 937-946, 1998.
    • (1998) IEEE J. Solid State Circuits , vol.33 , Issue.7 , pp. 937-946
    • Huang, Q.1    Oberle, M.2
  • 6
    • 0032180756 scopus 로고    scopus 로고
    • Conceptual Framework of a Remote Wireless Health Monitoring System for Large Civil Structures
    • D J Pines and P A Lovell, 'Conceptual Framework of a Remote Wireless Health Monitoring System for Large Civil Structures', Smart Mater. Struct., Vol 7, No 5, pp 627-636, 1998.
    • (1998) Smart Mater. Struct. , vol.7 , Issue.5 , pp. 627-636
    • Pines, D.J.1    Lovell, P.A.2
  • 7
    • 0028751855 scopus 로고
    • Real Time Ultrasonic Techniques Suitable for Implementing Non-Contact NDT Systems Employing Piezoceramic Composite Transducers
    • R Farlow and G Hayward, 'Real Time Ultrasonic Techniques Suitable for Implementing Non-Contact NDT Systems Employing Piezoceramic Composite Transducers', INSIGHT, Vol 36, No 12, pp 926-935, 1994.
    • (1994) INSIGHT , vol.36 , Issue.12 , pp. 926-935
    • Farlow, R.1    Hayward, G.2
  • 8
    • 0029775749 scopus 로고    scopus 로고
    • An Automated Ultrasonic NDT Scanner Employing Advanced Air-Coupled 1-3 Connectivity Composite Transducers
    • R Farlow and G Hayward, 'An Automated Ultrasonic NDT Scanner Employing Advanced Air-Coupled 1-3 Connectivity Composite Transducers', INSIGHT, Vol 38, No 1, pp 41-50, 1996.
    • (1996) INSIGHT , vol.38 , Issue.1 , pp. 41-50
    • Farlow, R.1    Hayward, G.2
  • 9
    • 0030189263 scopus 로고    scopus 로고
    • Applications of Through-Air Ultrasound for Rapid NDE Scanning in the Aerospace Industry
    • S P Kelly, R Farlow and G Hayward, 'Applications of Through-Air Ultrasound for Rapid NDE Scanning in the Aerospace Industry', IEEE Trans. Ultrason. Ferroelect. Freq. Cont., Vol 43, No 4, pp 678-689, 1996.
    • (1996) IEEE Trans. Ultrason. Ferroelect. Freq. Cont. , vol.43 , Issue.4 , pp. 678-689
    • Kelly, S.P.1    Farlow, R.2    Hayward, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.