메뉴 건너뛰기




Volumn 10, Issue 4, 2000, Pages 218-221

Laparoscopic placement of the Tenckhoff catheter for peritoneal dialysis

Author keywords

Cholecystectomy; Continuous ambulatory peritoneal dialysis; Incisional hernia; Laparoscopy; Renal disease

Indexed keywords

ADULT; AGED; ARTICLE; CATHETER; CATHETERIZATION; CLINICAL ARTICLE; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; FEMALE; HUMAN; LAPAROSCOPY; LAPAROTOMY; MALE; OPERATION DURATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 0033892919     PISSN: 10517200     EISSN: None     Source Type: Journal    
DOI: 10.1097/00129689-200008000-00007     Document Type: Article
Times cited : (123)

References (24)
  • 4
    • 0019461543 scopus 로고
    • Placement of the Tenckhoff peritoneal dialysis catheter under peritoneoscopic visualization
    • Ash SR, Wolf GC, Bloch R. Placement of the Tenckhoff peritoneal dialysis catheter under peritoneoscopic visualization. Dial Transplant 1981;10:383-5.
    • (1981) Dial Transplant , vol.10 , pp. 383-385
    • Ash, S.R.1    Wolf, G.C.2    Bloch, R.3
  • 5
    • 0030031226 scopus 로고    scopus 로고
    • Secure placement of peritoneal dialysis catheters using a laparoscopic technique
    • Watson DI, Paterson D, Bannister K. Secure placement of peritoneal dialysis catheters using a laparoscopic technique. Surg Laparosc Endosc 1996;6:35-7.
    • (1996) Surg Laparosc Endosc , vol.6 , pp. 35-37
    • Watson, D.I.1    Paterson, D.2    Bannister, K.3
  • 6
    • 0027257876 scopus 로고
    • Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients
    • Chao S-H, Tsai T-J. Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients. Nephron 1993;65:157-8.
    • (1993) Nephron , vol.65 , pp. 157-158
    • Chao, S.-H.1    Tsai, T.-J.2
  • 7
    • 0026212321 scopus 로고
    • Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters
    • Kittur DS, Gazaway PM, Abidin MR. Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters. Surg Laparosc Endosc 1991;3:179-82.
    • (1991) Surg Laparosc Endosc , vol.3 , pp. 179-182
    • Kittur, D.S.1    Gazaway, P.M.2    Abidin, M.R.3
  • 8
    • 0025230214 scopus 로고
    • Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD
    • Gibson DH, Heasley RN, Price JH, Doherty CC, Douglas JF. Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD [letter]. Clin Nephrol 1990;33:208.
    • (1990) Clin Nephrol , vol.33 , pp. 208
    • Gibson, D.H.1    Heasley, R.N.2    Price, J.H.3    Doherty, C.C.4    Douglas, J.F.5
  • 9
    • 0029302696 scopus 로고
    • Laparoscopic salvage of Tenckhoff catheters
    • Owens LV, Brader AH. Laparoscopic salvage of Tenckhoff catheters. Surg Endosc 1995;9:517-8.
    • (1995) Surg Endosc , vol.9 , pp. 517-518
    • Owens, L.V.1    Brader, A.H.2
  • 10
  • 11
    • 0023189627 scopus 로고
    • Extraperitoneal placement of Tenckhoff catheters: A cause of immediate malfunction
    • Perlmutt LM, Braun SD, Cohan RH, Dunnick NR. Extraperitoneal placement of Tenckhoff catheters: a cause of immediate malfunction. AJR Am J Roentgenol 1987;148:1211-2.
    • (1987) AJR Am J Roentgenol , vol.148 , pp. 1211-1212
    • Perlmutt, L.M.1    Braun, S.D.2    Cohan, R.H.3    Dunnick, N.R.4
  • 12
    • 0021368083 scopus 로고
    • Surgical aspects of continuous ambulatory peritoneal dialysis: 3 years experience
    • Francis DM, Donnelly PK, Veitch PS, et al. Surgical aspects of continuous ambulatory peritoneal dialysis: 3 years experience. Br J Surg 1984;71:225-9.
    • (1984) Br J Surg , vol.71 , pp. 225-229
    • Francis, D.M.1    Donnelly, P.K.2    Veitch, P.S.3
  • 13
    • 0021941753 scopus 로고
    • Surgical aspects of the Tenckhoff peritoneal dialysis catheter, a 7 year experience
    • Bullmaster JR, Miller SF, Finley RK, Jones LM. Surgical aspects of the Tenckhoff peritoneal dialysis catheter, a 7 year experience. Am J Surg 1985;149:339-42.
    • (1985) Am J Surg , vol.149 , pp. 339-342
    • Bullmaster, J.R.1    Miller, S.F.2    Finley, R.K.3    Jones, L.M.4
  • 14
    • 0021957973 scopus 로고
    • Chronic peritoneal dialysis: Mechanical and infectious complications
    • Swartz RD. Chronic peritoneal dialysis: mechanical and infectious complications. Nephron 1985;40:29-37.
    • (1985) Nephron , vol.40 , pp. 29-37
    • Swartz, R.D.1
  • 15
    • 0022379390 scopus 로고
    • Improved results with a paramedian technique for the insertion of peritoneal dialysis catheters
    • Spence PA, Mathews RE, Khanna R, Oreopoulos DG. Improved results with a paramedian technique for the insertion of peritoneal dialysis catheters. Surg Gynecol Obstet 1985;161:585-7.
    • (1985) Surg Gynecol Obstet , vol.161 , pp. 585-587
    • Spence, P.A.1    Mathews, R.E.2    Khanna, R.3    Oreopoulos, D.G.4
  • 16
    • 0021960833 scopus 로고
    • Peritoneoscopic placement of a Tenckhoff catheter for chronic peritoneal dialysis
    • Brunk E. Peritoneoscopic placement of a Tenckhoff catheter for chronic peritoneal dialysis. Endoscopy 1985;17:186-8.
    • (1985) Endoscopy , vol.17 , pp. 186-188
    • Brunk, E.1
  • 17
    • 0020678170 scopus 로고
    • Peritoneoscopy in chronic peritoneal dialysis use in evaluation and management of complications
    • Cunningham JT, Tucker CT. Peritoneoscopy in chronic peritoneal dialysis use in evaluation and management of complications. Gastroinlest Endosc 1983;29:47-50.
    • (1983) Gastroinlest Endosc , vol.29 , pp. 47-50
    • Cunningham, J.T.1    Tucker, C.T.2
  • 18
    • 0019461543 scopus 로고
    • Placement of the Tenckhoff peritoneal catheter under peritoneoscopic visualization
    • Ash SR, Wolf GC, Bloch R. Placement of the Tenckhoff peritoneal catheter under peritoneoscopic visualization. Dial Transplant 1981;10:383-5.
    • (1981) Dial Transplant , vol.10 , pp. 383-385
    • Ash, S.R.1    Wolf, G.C.2    Bloch, R.3
  • 19
    • 0026212321 scopus 로고
    • Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters
    • Kittur DS, Gasaway PM, Abidin MR. Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters. Surg Laparosc Endosc 1991;1:179-82.
    • (1991) Surg Laparosc Endosc , vol.1 , pp. 179-182
    • Kittur, D.S.1    Gasaway, P.M.2    Abidin, M.R.3
  • 20
    • 0021806650 scopus 로고
    • Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis
    • Wilson JA, Swartz RD. Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis. Dig Dis Sci 1985;30:465-7.
    • (1985) Dig Dis Sci , vol.30 , pp. 465-467
    • Wilson, J.A.1    Swartz, R.D.2
  • 21
    • 0018890232 scopus 로고
    • Laparoscopic removal of an intraperitoneal dialysis catheter
    • Maher PJ, Harries DJ, Goggin MJ. Laparoscopic removal of an intraperitoneal dialysis catheter. Br J Clin Pract 1980;34:226.
    • (1980) Br J Clin Pract , vol.34 , pp. 226
    • Maher, P.J.1    Harries, D.J.2    Goggin, M.J.3
  • 23
    • 0029125740 scopus 로고
    • Comparison for four techniques of catheter insertion in patients undergoing continuous ambulatory peritoneal dialysis
    • Hwang TL, Chen MF, Leu ML. Comparison for four techniques of catheter insertion in patients undergoing continuous ambulatory peritoneal dialysis. Eur J Surg 1995;161:401-4.
    • (1995) Eur J Surg , vol.161 , pp. 401-404
    • Hwang, T.L.1    Chen, M.F.2    Leu, M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.