메뉴 건너뛰기




Volumn 18, Issue 2, 2000, Pages 103-109

Measurement of fluid volume shifts during hemodialysis by A-mode ultrasonography

Author keywords

Hemodialysis; Inferior vena cava; Interstitial fluid; Monitoring; Tissue thickness; Ultrasound

Indexed keywords

A SCAN; ADULT; AGED; ARTICLE; BLOOD PRESSURE MONITORING; BLOOD VOLUME; CLINICAL ARTICLE; CONTROLLED STUDY; ECHOGRAPHY; FEMALE; FOREHEAD; HEART RATE; HEMATOCRIT; HEMODIALYSIS; HUMAN; HYPOTENSION; INFERIOR CAVA VEIN; MALE; MEAN ARTERIAL PRESSURE; MUSCLE CRAMP; MUSCLE TISSUE; PATIENT MONITORING; PRIORITY JOURNAL; THICKNESS; ULTRAFILTRATION; VERTIGO;

EID: 0033866930     PISSN: 02535068     EISSN: None     Source Type: Journal    
DOI: 10.1159/000014432     Document Type: Article
Times cited : (10)

References (29)
  • 1
    • 0027964816 scopus 로고
    • Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume
    • Bogaard HJ, de Vries JPPM, de Vries PMJM: Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume. Nephrol Dial Transplant 1994;9:1283-1287.
    • (1994) Nephrol Dial Transplant , vol.9 , pp. 1283-1287
    • Bogaard, H.J.1    De Vries, J.P.P.M.2    De Vries, P.M.J.M.3
  • 2
    • 0015504696 scopus 로고
    • Muscle cramps during maintenance hemodialysis
    • Stewart WK, Fleming LW, Manuel MA: Muscle cramps during maintenance hemodialysis. Lancet 1972;i:1049-1051.
    • (1972) Lancet , vol.1 , pp. 1049-1051
    • Stewart, W.K.1    Fleming, L.W.2    Manuel, M.A.3
  • 3
    • 0028234683 scopus 로고
    • Prevention of hypovolemia induced hypotension during hemodialysis by means of an optical reflection method
    • de Vries JPPM, Donker AJM, de Vries PMJM: Prevention of hypovolemia induced hypotension during hemodialysis by means of an optical reflection method. Int J Artif Organs 1994; 17:209-214.
    • (1994) Int J Artif Organs , vol.17 , pp. 209-214
    • De Vries, J.P.P.M.1    Donker, A.J.M.2    De Vries, P.M.J.M.3
  • 4
    • 0002430193 scopus 로고
    • Complications during hemodialysis
    • Nissenson AR, Fine RN, Gentile DE (eds): Norwalk, Appleton & Lange
    • Levin NW, Kupin WL, Zasuwa G, Venkat KK: Complications during hemodialysis; in Nissenson AR, Fine RN, Gentile DE (eds): Clinical Dialysis. Norwalk, Appleton & Lange, 1990, pp 172-201.
    • (1990) Clinical Dialysis , pp. 172-201
    • Levin, N.W.1    Kupin, W.L.2    Zasuwa, G.3    Venkat, K.K.4
  • 5
    • 0021720325 scopus 로고
    • Plasma volume recovery after ultrafiltration in patients with chronic renal failure
    • Koomans HA, Geers AB, Mees EJD: Plasma volume recovery after ultrafiltration in patients with chronic renal failure. Kidney Int 1984;26: 848-854.
    • (1984) Kidney Int , vol.26 , pp. 848-854
    • Koomans, H.A.1    Geers, A.B.2    Mees, E.J.D.3
  • 6
    • 0029012240 scopus 로고
    • Influence of hydration state of plasma volume changes during ultrafiltration
    • Wizeman V, Leibinger A, Mueller K, Nilson A: Influence of hydration state of plasma volume changes during ultrafiltration. Artif Organs 1995;19:416-419.
    • (1995) Artif Organs , vol.19 , pp. 416-419
    • Wizeman, V.1    Leibinger, A.2    Mueller, K.3    Nilson, A.4
  • 7
    • 0013523122 scopus 로고
    • Dynamics of vascular refilling
    • Atsumi K, Maekawa M, Ota K (eds) Cleveland, ISAO Press
    • Keshaviah PR, Ilstrup KM, Shapiro FL: Dynamics of vascular refilling: in Atsumi K, Maekawa M, Ota K (eds): Progress in Artificial Organs. Cleveland, ISAO Press, 1984, pp 506-510.
    • (1984) Progress in Artificial Organs , pp. 506-510
    • Keshaviah, P.R.1    Ilstrup, K.M.2    Shapiro, F.L.3
  • 9
    • 0002799739 scopus 로고
    • Structure, function and turnover of the extracellular matrix
    • Laurent TC: Structure, function and turnover of the extracellular matrix. Adv Microcirc 1987;13:15-34.
    • (1987) Adv Microcirc , vol.13 , pp. 15-34
    • Laurent, T.C.1
  • 10
    • 0019595572 scopus 로고
    • Interstitial fluid volume: Local regulatory mechanisms
    • Aukland K, Nicolaysen G: Interstitial fluid volume: Local regulatory mechanisms. Physiol Rev 1981;61:556-643.
    • (1981) Physiol Rev , vol.61 , pp. 556-643
    • Aukland, K.1    Nicolaysen, G.2
  • 11
    • 0003290637 scopus 로고
    • Interstitial fluid balance in experimental animals and man
    • Aukland K: Interstitial fluid balance in experimental animals and man. Adv Microcirc 1987;13:110-123.
    • (1987) Adv Microcirc , vol.13 , pp. 110-123
    • Aukland, K.1
  • 12
    • 0018888350 scopus 로고
    • A new mini plethysmograph to measure volume changes in small circumscribed tissue areas
    • Kirsch KA, Merke J, Hinghofer-Szalkay H, Barnkow M, Wicke HJ: A new mini plethysmograph to measure volume changes in small circumscribed tissue areas. Eur J Physiol 1980; 383:189-194.
    • (1980) Eur J Physiol , vol.383 , pp. 189-194
    • Kirsch, K.A.1    Merke, J.2    Hinghofer-Szalkay, H.3    Barnkow, M.4    Wicke, H.J.5
  • 14
    • 0001517342 scopus 로고
    • Red cell, plasma and blood volume in healthy men measured by radiochromium cell tagging and hematocrit: Influence of age, somatotype, and habits of physical activity on the variance after regression of volumes to height and weight combined
    • Wennesland R, Brown E, Hopper J Jr, Hodges JL Jr, Guttentag OE, Scott KG, Tucker IN, Bradley B: Red cell, plasma and blood volume in healthy men measured by radiochromium cell tagging and hematocrit: Influence of age, somatotype, and habits of physical activity on the variance after regression of volumes to height and weight combined. J Clin Invest 1959;38:1065-1077.
    • (1959) J Clin Invest , vol.38 , pp. 1065-1077
    • Wennesland, R.1    Brown, E.2    Hopper J., Jr.3    Hodges J.L., Jr.4    Guttentag, O.E.5    Scott, K.G.6    Tucker, I.N.7    Bradley, B.8
  • 15
    • 73649151893 scopus 로고
    • Red cell, plasma and blood volume in healthy women measured by radiochromium cell-labelling and hematocrit
    • Brown E, Hopper J Jr, Hodges JL Jr, Bradley B, Wennesland R, Yamuchi H: Red cell, plasma and blood volume in healthy women measured by radiochromium cell-labelling and hematocrit. J Clin Invest 1962;41:2182-2190.
    • (1962) J Clin Invest , vol.41 , pp. 2182-2190
    • Brown, E.1    Hopper J., Jr.2    Hodges J.L., Jr.3    Bradley, B.4    Wennesland, R.5    Yamuchi, H.6
  • 16
    • 84960600145 scopus 로고
    • Echography of the inferior vena cava is a simple and reliable tool for estimation of 'dry weight' in haemodialysis patients
    • Cheriex EC, Leunissen KML, Jansen JHA, Mooy JMV, van Hooff JP: Echography of the inferior vena cava is a simple and reliable tool for estimation of 'dry weight' in haemodialysis patients. Nephrol Dial Transplant 1989;4:563-568.
    • (1989) Nephrol Dial Transplant , vol.4 , pp. 563-568
    • Cheriex, E.C.1    Leunissen, K.M.L.2    Jansen, J.H.A.3    Mooy, J.M.V.4    Van Hooff, J.P.5
  • 17
    • 0018871297 scopus 로고
    • Fluid volume distribution within superficial shell tissues along body axis during changes of body posture in man
    • Kirsch KA, Merke J, Hinghofer-Szalkay H, Wicke HJ: Fluid volume distribution within superficial shell tissues along body axis during changes of body posture in man. Eur J Physiol 1980;383:195-201.
    • (1980) Eur J Physiol , vol.383 , pp. 195-201
    • Kirsch, K.A.1    Merke, J.2    Hinghofer-Szalkay, H.3    Wicke, H.J.4
  • 18
    • 0027268267 scopus 로고
    • Fluid shifts into and out of superficial tissues under microgravity and terrestrial conditions
    • Kirsch KA, Baartz FJ, Gunga HC, Röcker L, Wicke HJ, Bünsch B: Fluid shifts into and out of superficial tissues under microgravity and terrestrial conditions. Clin Invest 1993;71: 687-689.
    • (1993) Clin Invest , vol.71 , pp. 687-689
    • Kirsch, K.A.1    Baartz, F.J.2    Gunga, H.C.3    Röcker, L.4    Wicke, H.J.5    Bünsch, B.6
  • 19
    • 0018345949 scopus 로고
    • Determining skin thickness with pulsed ultrasound
    • Alexander H, Miller DL: Determining skin thickness with pulsed ultrasound. J Invest Dermatol 1979;72:17-19.
    • (1979) J Invest Dermatol , vol.72 , pp. 17-19
    • Alexander, H.1    Miller, D.L.2
  • 20
    • 0017668252 scopus 로고
    • Measurement of skin thickness: A comparison of two in vivo techniques with the conventional histometric method
    • Dykes PJ, Marks R: Measurement of skin thickness: A comparison of two in vivo techniques with the conventional histometric method. J Dermatol 1977;69:275-278.
    • (1977) J Dermatol , vol.69 , pp. 275-278
    • Dykes, P.J.1    Marks, R.2
  • 21
    • 0001887591 scopus 로고    scopus 로고
    • The body fluid compartments: Extracellular and intracellular fluids: Interstitial fluid and edema
    • Guyton AC, Hall JE (eds): Philadelphia, Saunders
    • Guyton AC, Hall JE: The body fluid compartments: Extracellular and intracellular fluids: Interstitial fluid and edema: in Guyton AC, Hall JE (eds): Textbook of Medical Physiology. Philadelphia, Saunders, 1996, pp 297-313.
    • (1996) Textbook of Medical Physiology , pp. 297-313
    • Guyton, A.C.1    Hall, J.E.2
  • 22
  • 23
    • 0032468598 scopus 로고    scopus 로고
    • Perioperative tissue thickness measurement by a new miniature ultrasound device
    • Schumacher J, Eichler W, Bauer O, Klotz KF: Perioperative tissue thickness measurement by a new miniature ultrasound device. J Clin Monit 1998;14:471-476.
    • (1998) J Clin Monit , vol.14 , pp. 471-476
    • Schumacher, J.1    Eichler, W.2    Bauer, O.3    Klotz, K.F.4
  • 24
    • 0031933854 scopus 로고    scopus 로고
    • Evaluating volume status in hemodialysis patients
    • Leypoldt JK, Cheung AK: Evaluating volume status in hemodialysis patients. Adv Ren Replace Ther 1998;5:64-74.
    • (1998) Adv Ren Replace Ther , vol.5 , pp. 64-74
    • Leypoldt, J.K.1    Cheung, A.K.2
  • 25
    • 0029743549 scopus 로고    scopus 로고
    • Use of continuous blood volume monitoring to detect inadequately high dry weight
    • Lopot F, Kotyk P, Blàha J, Foreit J: Use of continuous blood volume monitoring to detect inadequately high dry weight. Int J Artif Organs 1996;19:411-414.
    • (1996) Int J Artif Organs , vol.19 , pp. 411-414
    • Lopot, F.1    Kotyk, P.2    Blàha, J.3    Foreit, J.4
  • 28
    • 0021741906 scopus 로고
    • Estimated lean body mass as an index for normalization of body fluids in humans
    • Boer P: Estimated lean body mass as an index for normalization of body fluids in humans. Am J Physiol 1984;247:F632-F636.
    • (1984) Am J Physiol , vol.247
    • Boer, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.