The incidence of acute cardiorespiratory and vascular dysfunction following intramedullary nail fixation of femoral metastasis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE METASTASIS; CLINICAL ARTICLE; DISEASE ASSOCIATION; FEMALE; FEMUR FRACTURE; HUMAN; HYPOTENSION; INCIDENCE; INTRAMEDULLARY NAILING; INTRAOPERATIVE PERIOD; MALE; OXYGEN SATURATION; SURGICAL RISK;

EID: 0033858831     PISSN: 00016470     EISSN: None     Source Type: Journal    
DOI: 10.1080/000164700317413111     Document Type: Article
Times cited : (49)

References (47)
  • 4
    • 0030954041 scopus 로고    scopus 로고
    • Cement implantation syndrome: A time limited embolic phenomenon
    • (1997) Can J Anaesth , vol.44 , pp. 107-111
    • Byrick, R.J.1
  • 10
    • 0031450022 scopus 로고    scopus 로고
    • Cardiorespiratory and vascular dysfunction related to major reconstructive orthopaedic surgey
    • (1997) Acta Orthop Scand , vol.68 , pp. 607-614
    • Dahl, O.E.1
  • 11
    • 0024564451 scopus 로고
    • Intra-operative collapse or death related to the use of acrylic cement in hip surgery
    • (1989) Anaesthesia , vol.44 , pp. 149-153
    • Duncan, J.A.1
  • 13
    • 0029045559 scopus 로고
    • Cardiac arrest during total knee replacement using a long-stem prosthesis
    • (1995) J Clin Anesth , vol.7 , pp. 253-263
    • Enneking, F.K.1
  • 15
    • 0028107761 scopus 로고
    • Transient cardiac standstill associated with embolic phenomena diagnosed by intraoperative transesophageal echocardiography during cemented total hip arthroplasty
    • (1994) Anesth Analg , vol.79 , pp. 382-385
    • Fitzgerald, R.1    Mason, L.2    Kanumilli, V.3
  • 19
    • 0030769478 scopus 로고    scopus 로고
    • Orthopedic surgical management of skeletal complications of malignancy
    • (1997) Cancer , vol.80 , pp. 1614-1627
    • Harrington, K.D.1
  • 21
    • 0027858282 scopus 로고
    • Intramedullary pressure in reamed and unreamed nailing of the femur and tibia - An in vitro study in intact, human bones
    • (1993) Injury , vol.24 , pp. 56-63
    • Heim, D.1    Schlegel, U.2    Perren, S.M.3
  • 30
    • 0030862671 scopus 로고    scopus 로고
    • Respiratory complications of bone cement insertion during total hip replacement under spinal anaesthesia
    • (1997) Eur J Anaesth , vol.14 , pp. 52-54
    • Lewis, R.N.1
  • 35
    • 0027881748 scopus 로고
    • Effect of flexible drive diameter and reamer design on the increase of pressure in the medullary cavity during reaming
    • (1993) Injury , vol.24 , pp. 40-47
    • Muller, C.1    Frigg, R.2    Pfister, U.3
  • 38
    • 0027848873 scopus 로고
    • Influence of the reamer shape on intraosseous pressure during closed intramedullary nailing of the unbroken femur: A preliminary report
    • (1993) Injury , vol.24 , pp. 48-55
    • Peter, R.E.1    Selz, T.2    Koestli, A.3
  • 40
    • 0027889484 scopus 로고
    • Cardiovascular collapse associated with the use of methylmethacrylate
    • (1993) AANA J , vol.61 , pp. 613-616
    • Pinto, P.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.