메뉴 건너뛰기




Volumn 33, Issue 3, 2000, Pages 253-260

Atrial sensing performance of a single-lead VDD pacing system during physical activities

Author keywords

Atrial sensing; Atrial synchronous ventricular pacing; Single lead VDD pacing

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CLINICAL ARTICLE; EXERCISE; FOLLOW UP; HEART VENTRICLE PACING; HUMAN; MEASUREMENT; P WAVE; PHYSICAL ACTIVITY; PRIORITY JOURNAL; SINUS NODE;

EID: 0033854616     PISSN: 00220736     EISSN: None     Source Type: Journal    
DOI: 10.1054/jelc.2000.8234     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 0032492742 scopus 로고    scopus 로고
    • Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on pacemaker implantation)
    • (1998) Circulation , vol.97 , pp. 1325
    • Gregoratos, G.1    Cheitlin, M.D.2    Conill, A.3
  • 4
    • 0008360953 scopus 로고    scopus 로고
    • Single lead atrial synchronised ventricular (VDD) pacing
    • Oto MA (ed), Practice and progress in cardiac pacing and electrophysiology. Dordrecht, The Netherlands: Kluwer Academic Publishers
    • (1996) , pp. 119
    • Crick, J.C.P.1
  • 7
    • 0025041888 scopus 로고
    • Experience and implantation techniques with new single-pass lead VDD pacing system
    • (1990) PACE , vol.13 , pp. 927
    • Longo, E.1    Catrini, V.2
  • 8
    • 0008402277 scopus 로고
    • Single lead VDD pacing
    • GE Antonioli, AE Aubert, H Ector (eds). Pacemaker Leads. Amsterdam, The Netherlands: Elsevier
    • (1991) , pp. 183
    • Furman, S.1    Gross, J.2    Andrews, C.3
  • 9
    • 0025719452 scopus 로고
    • European multicenter prospective follow-up study of 1002 implants of a single lead VDD pacing system
    • (1991) PACE , vol.14 , pp. 1742
    • Crick, J.C.P.1
  • 10
    • 0026020317 scopus 로고
    • Multicenter evaluation of a single-pass lead VDD pacing system
    • Multicenter Study Group
    • (1991) PACE , vol.14 , pp. 434
    • Curzio, G.1
  • 13
    • 0028089781 scopus 로고
    • Long-term reliability of single lead atrial synchronous pacing systems using closely spaced atrial dipoles: Five-year experience
    • (1994) PACE , vol.17 , pp. 1865
    • Ansani, L.1    Percoco, G.F.2    Guardigli, G.3
  • 19
    • 0028027767 scopus 로고
    • Long term stability of P wave sensing in single lead VDDR pacing: Clinical versus subclinical atrial undersensing
    • (1994) PACE , vol.17 , pp. 1849
    • Lau, C.P.1    Tai, Y.T.2    Leung, S.K.3
  • 20
    • 0027942107 scopus 로고
    • Comparative evaluation of bipolar atrial electrogram amplitude during everyday activities: Atrial active fixation versus two types of single pass VDD/R leads
    • (1994) PACE , vol.17 , pp. 1873
    • Chan, C.C.1    Lau, C.P.2    Leung, S.K.3
  • 21
    • 0029865830 scopus 로고    scopus 로고
    • Dependence of atrial sensing function on posture in a single-lead atrial triggered ventricular (VDD) pacemaker
    • (1996) PACE , vol.19 , pp. 309
    • Toivonen, L.1    Lommi, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.