메뉴 건너뛰기




Volumn 2, Issue 4, 2000, Pages 307-312

Reliability of nitrogen dioxide passive diffusion tubes for ambient measurement: In situ properties of the triethanolamine absorbent

(3)  Kirby, C a   Fox, M a   Waterhouse, J a  

a NONE   (United Kingdom)

Author keywords

[No Author keywords available]

Indexed keywords

ACETONE; NITROGEN DIOXIDE; TRIETHANOLAMINE;

EID: 0033807858     PISSN: 14640325     EISSN: None     Source Type: Journal    
DOI: 10.1039/b003124k     Document Type: Article
Times cited : (27)

References (23)
  • 7
    • 0007862658 scopus 로고    scopus 로고
    • UK Nitrogen Dioxide Survey 1997, Report AEAT 4565, AEA Technology National Environmental Technology Centre Culham UK
    • (1997)
    • Bush, T.1    Mooney, D.2    Stevenson, K.J.3
  • 8
    • 0007759520 scopus 로고    scopus 로고
    • Department of the Environment, Transport and the Regions, A Better Quality of Life: A Strategy for Sustainable Development for the UK, HMSO
    • (1999)
  • 9
    • 0007761985 scopus 로고
    • Health and Safety Executive, Methods for the Determination of Hazardous Substances - Protocol for Assessing the Performance of a Diffusive Sampler, MDHS 27, HMSO, London
    • (1994)
  • 10
    • 0007761986 scopus 로고    scopus 로고
    • Workplace Atmospheres - Protocol for Evaluating the Performance of Diffusive Samplers, ISO 16107, Geneva, Switzerland
    • (1999)
  • 15
    • 0007855250 scopus 로고    scopus 로고
    • PhD Thesis, Anglia Polytechnic University, Cambridge
    • (1999)
    • Kirby, C.1
  • 23
    • 0007815931 scopus 로고    scopus 로고
    • Details of method supplied by Gradko International of Winchester, Winchester, UK


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.