메뉴 건너뛰기




Volumn 24, Issue 9, 2000, Pages 90-114

Considerations in using 'bubble point' type tests as filter integrity tests, Part I: Effect of test methodology on filter cartridge 'bubble point' measurements and implications for the use of 'bubble point' type tests as correlated tests

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATION; FILTER; LABORATORY TEST; MEASUREMENT; METHODOLOGY; REVIEW;

EID: 0033795802     PISSN: 01478087     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (15)

References (29)
  • 1
    • 0007833754 scopus 로고    scopus 로고
    • USP 24/NF 19, general chapter (1211) 'Sterilization and Sterility Assurance' (United States Pharmacopeial Convention, Inc., Rockville, MD)
    • (1999) , pp. 2143-2148
  • 3
    • 0007737491 scopus 로고
    • FDA, 'Guideline on Sterile Drug Products produced by Aseptic Processing' (Center for Drug and Biologics and Office of Regulatory Affairs, FDA, Rockville, MD)
    • (1987)
  • 4
    • 0016529145 scopus 로고
    • Quality control of absolute bacteria removal filters
    • (1975) Bull. PDA , vol.29 , Issue.4 , pp. 192-204
    • Pall, D.B.1
  • 5
    • 0007787031 scopus 로고
    • 'Method and Apparatus for Determining the Maximum Pore Size of Hydraulic Filter Elements,' US Patent No. 3007334
    • (1961)
    • Pall, D.B.1
  • 7
    • 0007734196 scopus 로고    scopus 로고
    • Fluid Sterilization by Filtration: The Filter Integrity Test and Other Filtration Topics (Interpharm Press, 2d ed., Buffalo Grove, IL)
    • (1997)
    • Johnston, P.R.1
  • 8
    • 0001159318 scopus 로고    scopus 로고
    • Characterization of MF/UF membranes
    • Microfiltration and Ultrafiltration, L.J. Zeman and A.L. Zydney, Eds. (Marcel Dekker, Inc., New York)
    • (1996) , pp. 180-292
    • Zeman, L.J.1
  • 9
    • 4243512472 scopus 로고
    • The integrity tests
    • Filtration in the Pharmaceutical Industry, T.H. Meltzer, Ed. (Marcel Dekker, Inc., New York)
    • (1987) , pp. 219-298
    • Meltzer, T.H.1
  • 10
    • 4243683616 scopus 로고
    • Validation of aseptic processing filters
    • Validation of Aseptic Pharmaceutical Processes, F.J. Carleton and J.P. Agalloco, Eds. (Marcel Dekker, Inc., New York)
    • (1986) , pp. 427-472
    • Errico, J.J.1
  • 11
    • 0002479522 scopus 로고
    • Principles of integrity-testing hydrophilic microporous membrane filters, Part I
    • (1989) Pharm. Technol. , vol.13 , Issue.9 , pp. 68-77
    • Emory, S.F.1
  • 13
    • 0030164781 scopus 로고    scopus 로고
    • Sensitivity considerations in hydrophobic filter integrity testing
    • Validation Practices for Biotechnology Products, ASTM STP 1260, J.K. Shillenn, Ed. (American Society for Testing and Materials, Philadelphia, PA)
    • (1996) , pp. 56-71
    • Steere, W.C.1    Scheer, L.A.2    Hubbert, M.3
  • 17
    • 0007735353 scopus 로고
    • Fluid filter media: Measuring the average pore size and the pore-size distribution, and correlation with results of filtration tests
    • (1985) J. Testing and Evaluation , vol.13 , Issue.4 , pp. 305-311
    • Johnston, P.R.1
  • 20
    • 4243753855 scopus 로고
    • Bacteria removal prediction in membrane filters
    • presented at 52nd Colloid and Surface Science Symposium, University of Tennessee, Knoxville, Tennessee. 12 June 1978 (available from Pall Corporation as Scientific and Technical Report STR PUF 13, Pall Corporation)
    • (1990)
    • Pall, D.B.1    Kirnbauer, E.2
  • 21
    • 0007783667 scopus 로고
    • 'Bubble-Point Determinations: A Comparison of Manual vs. Automated Methods,' in Fluid Filtration: Liquid, Volume II, ASTM STP 975, P.R. Johnston and H.G. Schroeder, Eds. (American Society for Testing and Materials, Philadelphia, PA
    • (1986)
    • Wolber, P.M.1    McAllister, M.A.2
  • 23
    • 0007833564 scopus 로고
    • Millipore Corporation, 'Validation Guide: Integritest II/II PLUS Automatic Integrity Tester,' Lit. No. VG009, Rev. 3 (Millipore Corporation, Bedford, MA
    • (1995)
  • 24
    • 0007785567 scopus 로고    scopus 로고
    • Pall Corporation, 'Palltronic Truflow Filter Integrity Test Instrument - Validation Guide,' Publication PBB-TF01P (Pall Corporation, East Hills, NY
    • (1996)
  • 25
    • 0007836426 scopus 로고
    • Pall Corporation, 'Validation Guide for the Palltronic Model FFE03-P-P Filter Integrity Test Instrument,' Publication TR-FFE03-P (Pall Corporation, East Hills, NY
    • (1987)
  • 27
    • 0002479522 scopus 로고
    • Principles of integrity-testing hydrophilic microporous membrane filters, Part II
    • (1989) Pharm. Technol. , vol.13 , Issue.10 , pp. 36-46
    • Emory, S.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.