메뉴 건너뛰기




Volumn 23, Issue 10 I, 2000, Pages 1509-1515

Clinical evaluation of a pacemaker algorithm that adjusts the pacing rate during sleep using activity variance

Author keywords

Activity variance; Circadian rate; Pacemaker; Sensors; Sleep rate

Indexed keywords

ACTIMETRY; ADULT; AGED; ALGORITHM; ARTICLE; ARTIFICIAL HEART PACEMAKER; CIRCADIAN RHYTHM; CLINICAL ARTICLE; FEMALE; HUMAN; IMPLANTATION; MALE; SLEEP; SLEEP TIME; SLEEP WAKING CYCLE;

EID: 0033786376     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2000.01509.x     Document Type: Article
Times cited : (17)

References (19)
  • 2
    • 0030789675 scopus 로고    scopus 로고
    • Vibration, acceleration, gravitation, and movement: Activity controlled rate adaptive pacing during treadmill exercise testing and daily life activities
    • (1997) PACE , vol.20 , pp. 1777-1786
    • Candinas, R.1    Jakob, M.2    Buckingham, T.A.3
  • 3
    • 0031019208 scopus 로고    scopus 로고
    • Age and sex related changes in heart rate to ventilation coupling: Implications for rate adaptive pacemaker algorithms
    • (1997) PACE , vol.20 , pp. 104-111
    • Rickli, H.1    MacCarter, D.J.2    Maire, R.3
  • 4
    • 0029128212 scopus 로고
    • Comparison of sinus node response to exercise with responses from two different activity-based rate adaptive pacemakers in healthy subjects of different age groups
    • (1995) PACE , vol.18 , pp. 1882-1888
    • Roberts, D.H.1    Baxter, S.E.2    Brennan, P.T.3
  • 5
    • 0003384534 scopus 로고    scopus 로고
    • Present status of rate-adaptive pacemakers. Should we be satisfied?
    • M Santini (ed.): Progress in Clinical Pacing. Armonk, NY, Futura Media
    • (1997) , pp. 153-163
    • Barold, S.S.1
  • 6
    • 0025679540 scopus 로고
    • Circadian rate variation in rate-adaptive pacing systems
    • (1990) PACE , vol.13 , pp. 1797-1801
    • Lee, M.T.1    Baker, R.2
  • 8
    • 2242466229 scopus 로고    scopus 로고
    • Sleep rate pacing based on activity variance
    • KK Sethi (ed.); Proceedings of the VIth Asian Pacific Symposium on Cardiac Pacing and Electrophysiology. Bologna, Italy, Monduzzi Editore S.P.A.
    • (1997) , pp. 159-163
    • Wildiars, A.1    De Vusser, Ph.2
  • 9
    • 0031878216 scopus 로고    scopus 로고
    • Automatic adaptation of the basic pacing rate in response to minute ventilation. Chorum French Investigational Group
    • (1998) PACE , vol.21 , pp. 1405-1409
    • Limousin, M.1    Pioger, G.2    Bonnet, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.