메뉴 건너뛰기




Volumn 52, Issue 3, 2000, Pages 195-208

Performance of hardened wet-process sprayed mortars

Author keywords

[No Author keywords available]

Indexed keywords

AIR PERMEABILITY; BENDING STRENGTH; BOND STRENGTH (MATERIALS); COMPRESSIVE STRENGTH; CONCRETE REINFORCEMENTS; DENSITY (SPECIFIC GRAVITY); ELASTIC MODULI; SHRINKAGE; SPRAYING; TENSILE STRENGTH;

EID: 0033728616     PISSN: 00249831     EISSN: None     Source Type: Journal    
DOI: 10.1680/macr.2000.52.3.195     Document Type: Article
Times cited : (17)

References (36)
  • 1
    • 0033346776 scopus 로고    scopus 로고
    • The rheological performance of wet-process sprayed mortars
    • AUSTIN S. A., ROBINS P. J. and GOODIER C. I. The rheological performance of wet-process sprayed mortars. Magazine of Concrete Research, 1999, 51, No. 5, 341-352.
    • (1999) Magazine of Concrete Research , vol.51 , Issue.5 , pp. 341-352
    • Austin, S.A.1    Robins, P.J.2    Goodier, C.I.3
  • 2
    • 0030736679 scopus 로고    scopus 로고
    • Repair with sprayed concrete
    • AUSTIN S. A. Repair with sprayed concrete. Concrete, 1997, 31, No. 1, 18-26.
    • (1997) Concrete , vol.31 , Issue.1 , pp. 18-26
    • Austin, S.A.1
  • 3
    • 0029287933 scopus 로고
    • Repair material properties which influence long-term performance of concrete structures
    • MANGAT P. S. and LIMBACHIYA M. K. Repair material properties which influence long-term performance of concrete structures. Construction and Building Materials, 1994, 9, No. 2, 81-90.
    • (1994) Construction and Building Materials , vol.9 , Issue.2 , pp. 81-90
    • Mangat, P.S.1    Limbachiya, M.K.2
  • 4
    • 0000481721 scopus 로고
    • Significance of property mismatch in the patch repair of structural concrete. Part 1, properties of repair system
    • EMBERSON M. K. and MAYS G. C. Significance of property mismatch in the patch repair of structural concrete. Part 1, properties of repair system. Magazine of Concrete Research, 1990, 42, No. 152, 147-160.
    • (1990) Magazine of Concrete Research , vol.42 , Issue.152 , pp. 147-160
    • Emberson, M.K.1    Mays, G.C.2
  • 7
    • 0020283942 scopus 로고
    • Site-produced sprayed concrete
    • HILLS D. L. Site-produced sprayed concrete. Concrete, 1982, 16, No. 12, 44-50.
    • (1982) Concrete , vol.16 , Issue.12 , pp. 44-50
    • Hills, D.L.1
  • 11
    • 0343093452 scopus 로고    scopus 로고
    • Sprayed concrete repairs - Their structural effectiveness
    • ed S. A. Austin Spon, London
    • MAYS G. C. and BARNES R. A. Sprayed concrete repairs - their structural effectiveness. Sprayed Concrete Technology, (ed S. A. Austin) Spon, London, 1996.
    • (1996) Sprayed Concrete Technology
    • Mays, G.C.1    Barnes, R.A.2
  • 12
    • 0343093451 scopus 로고    scopus 로고
    • Sprayed concrete for the strengthening of masonry arch bridges
    • ed S. A. Austin Spon, London
    • PEASTON C. H., CHOO B. S. and GONG N. G. Sprayed concrete for the strengthening of masonry arch bridges. Sprayed Concrete Technology, (ed S. A. Austin) Spon, London, 1996.
    • (1996) Sprayed Concrete Technology
    • Peaston, C.H.1    Choo, B.S.2    Gong, N.G.3
  • 13
    • 36549049999 scopus 로고
    • Quality and quality variations of wet and dry mix shotcrete - Experiences from Grodinge railway track project
    • MALMBERG B. Quality and quality variations of wet and dry mix shotcrete - experiences from Grodinge railway track project. Shotcrete for Underground Support VII, Telfs, Austria, 1995, 251-258.
    • (1995) Shotcrete for Underground Support Vii, Telfs, Austria , pp. 251-258
    • Malmberg, B.1
  • 14
  • 21
    • 85037785944 scopus 로고    scopus 로고
    • CEN, Brussels, TC104/WG10/TG3
    • COMITÉ EUROPÉEN DE NORMALISATION. Report of 8th Meeting. CEN, Brussels, 1999, TC104/WG10/TG3.
    • (1999) Report of 8th Meeting
  • 27
    • 0040335590 scopus 로고
    • Tentative recommendations no. 11.2, absorption of water by capillary
    • RILEM TECHNICAL COMMITTEE 14-CPC. Tentative recommendations No. 11.2, absorption of water by capillary. Materials and Structures, 1974, 7, No. 40, 295-297.
    • (1974) Materials and Structures , vol.7 , Issue.40 , pp. 295-297
  • 28
    • 85037806213 scopus 로고    scopus 로고
    • Private communication
    • DUNLOP A. J. Private communication.
    • Dunlop, A.J.1
  • 29
    • 85037794352 scopus 로고    scopus 로고
    • Private communication
    • ROXBRUGH G. Private communication.
    • Roxbrugh, G.1
  • 30
    • 0343965227 scopus 로고    scopus 로고
    • Sprayed Concrete Association, Aldershot, UK
    • SPRAYED CONCRETE ASSOCIATION. An introduction to sprayed concrete. Sprayed Concrete Association, Aldershot, UK, 1999.
    • (1999) An Introduction to Sprayed Concrete
  • 31
    • 14944354961 scopus 로고
    • Construction practice and quality control
    • eds S. A. Austin and P. J. Robins. Whittles, Latheronwheel
    • GEBLER S. H. Construction practice and quality control. In Sprayed Concrete: Properties, Design and Application (eds S. A. Austin and P. J. Robins). Whittles, Latheronwheel, 1995, pp. 204-228.
    • (1995) Sprayed Concrete: Properties, Design and Application , pp. 204-228
    • Gebler, S.H.1
  • 32
    • 85037803804 scopus 로고
    • The Crom Corporation, Gainsville, Florida
    • CROM T. Dry Mix Shotcrete Nozzleing. The Crom Corporation, Gainsville, Florida, 1985.
    • (1985) Dry Mix Shotcrete Nozzleing
    • Crom, T.1
  • 33
    • 0028482790 scopus 로고
    • Steel-fiber-reinforced wet-mix shotcrete: Comparisons with cast concrete
    • BANTHIA N., TROTTIER J. F. and BEAUPRE D. Steel-fiber-reinforced wet-mix shotcrete: comparisons with cast concrete. Journal of Materials in Civil Engineering, 1994, 6, No. 3, pp. 430-437.
    • (1994) Journal of Materials in Civil Engineering , vol.6 , Issue.3 , pp. 430-437
    • Banthia, N.1    Trottier, J.F.2    Beaupre, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.