메뉴 건너뛰기




Volumn 32, Issue 3, 2000, Pages 201-204

Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy

Author keywords

[No Author keywords available]

Indexed keywords

IONIZATION CHAMBERS; PHOTONS; RADIOTHERAPY; SKIN; X RAYS;

EID: 0033727978     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4487(99)00276-0     Document Type: Article
Times cited : (92)

References (9)
  • 1
    • 0020137053 scopus 로고
    • A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations
    • Constanitinou C., Attix F., Paliwal B. A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations. Med. Phys. 9:1982;436-441.
    • (1982) Med. Phys. , vol.9 , pp. 436-441
    • Constanitinou, C.1    Attix, F.2    Paliwal, B.3
  • 2
    • 0026131834 scopus 로고
    • Measurement of skin dose in primary irradiation of maxillary sinus carcinoma
    • Janjan, Zellmer, Gillin, Kengchon, Cambell. Measurement of skin dose in primary irradiation of maxillary sinus carcinoma. Med. Dosim. 16:1991;33-36.
    • (1991) Med. Dosim. , vol.16 , pp. 33-36
    • Janjan1    Zellmer2    Gillin3    Kengchon4    Cambell5
  • 5
    • 0026513365 scopus 로고
    • The surface dosage in the radiotherapy of a small breast carcinoma with 6MV x-rays. A contribution to quality assurance in radiotherapy
    • Muller-Sievers, Kober, Semrau, 1992. The surface dosage in the radiotherapy of a small breast carcinoma with 6MV x-rays. A contribution to quality assurance in radiotherapy. Strahlenther Onkol 168, pp. 291-296.
    • (1992) Strahlenther Onkol , vol.168 , pp. 291-296
    • Muller-Sievers1    Kober2    Semrau3