메뉴 건너뛰기




Volumn 147, Issue 4, 2000, Pages 193-195

Calibration of IVDs at frequencies up to 1 MHz by permuting capacitors

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; CAPACITORS; MEASUREMENT ERRORS; PRINTED CIRCUIT BOARDS; VOLTAGE DIVIDERS;

EID: 0033689179     PISSN: 13502344     EISSN: None     Source Type: Journal    
DOI: 10.1049/ip-smt:20000388     Document Type: Article
Times cited : (22)

References (9)
  • 1
    • 0026142356 scopus 로고
    • A new universal calibration method for four-terminalpair admittance standards', IEEE Trails. lustrum
    • SUZUKI, K.: 'A new universal calibration method for four-terminalpair admittance standards', IEEE Trails. lustrum. Mean., 1991, 40, (2), pp. 420-422
    • (1991) Mean. , vol.40 , Issue.2 , pp. 420-422
    • Suzuki, K.1
  • 2
    • 0032679595 scopus 로고    scopus 로고
    • D., ZAMUROVIC, S.A., WALTRIP, B.C., and OLDHAM, N.M.: 'Uncertainty analysis for four terminal-pair capacitance and dissipation factor characterisation at 1 MHz and 10 MHz'
    • KOFFMAN, A.D., ZAMUROVIC, S.A., WALTRIP, B.C., and OLDHAM, N.M.: 'Uncertainty analysis for four terminal-pair capacitance and dissipation factor characterisation at 1 MHz and 10 MHz'. Proceedings of the 16th IEEE IMTO'99, Venice, Italy. 1999, Vol. 3, pp. 1459-1462.
    • (1999) Proceedings of the 16th IEEE IMTO'99, Venice, Italy. , vol.3 , pp. 1459-1462
    • Koffman, A.1
  • 3
    • 84937352182 scopus 로고
    • D., and SHIELDS, J.Q.: The precision measurement of transformer ratios', IRE Trans
    • CUTKOSKY, R.D., and SHIELDS, J.Q.: The precision measurement of transformer ratios', IRE Trans. Instrwn., 1960, pp. 243-250
    • (1960) Instrwn. , pp. 243-250
    • Cutkosky, R.1
  • 6
    • 33749904462 scopus 로고    scopus 로고
    • A., KIBBLE, B.P., and ROBINSON, I.A.: Towards calibration of IVDs up to 1 MHz usina permutinc capacitors method'
    • AWAN, S.A., KIBBLE, B.P., and ROBINSON, I.A.: Towards calibration of IVDs up to 1 MHz usina permutinc capacitors method'. Proceedings of BEMC 99, Brighton, 'UK, November 1999, 0
    • (1999) Proceedings of BEMC 99, Brighton, 'UK, November , pp. 0
    • Awan, S.1
  • 7
    • 33749920385 scopus 로고
    • N.: 'Evaluation of three-terminal and four-terminal pair capacitors at high frequencies'
    • JONES, R.N.: 'Evaluation of three-terminal and four-terminal pair capacitors at high frequencies'. NBS technical note 1024, 1980
    • (1024) NBS Technical Note , pp. 1980
    • Jones, R.1
  • 8
    • 0017269107 scopus 로고
    • A step-up method for calibrating inductive voltace dividers up to 1 MHz', IEEE Trans
    • GROHMANN, K.: 'A step-up method for calibrating inductive voltace dividers up to 1 MHz', IEEE Trans. Instrwn. Mcas., 1976, I.M-25, (4), pp. 516-518
    • (1976) Instrwn. Mcas. , vol.25 , Issue.4 , pp. 516-518
    • Grohmann, K.1
  • 9
    • 1942448410 scopus 로고
    • J., and DEACON, T.A.: Theory, design and measurement of inductive voltage dividers', Proc
    • HILL, J.J., and DEACON, T.A.: Theory, design and measurement of inductive voltage dividers', Proc. IEE. 1968, 115, (5), pp. 727-735
    • (1968) IEE. , vol.115 , Issue.5 , pp. 727-735
    • Hill, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.