메뉴 건너뛰기




Volumn 27, Issue 11, 2000, Pages 2480-2493

Virtual micro-intensity modulated radiation therapy

Author keywords

IMRT; Junctions; Micro IMRT; Optimization; Segmentation

Indexed keywords

IMAGE SEGMENTATION; OPTIMIZATION; WAVEGUIDE JUNCTIONS;

EID: 0033678929     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1315314     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 33744572706 scopus 로고
    • Is high resolution obtainable on both the blade tip and the edge of the Philips multileaf collimator? What techniques are required to achieve this?
    • (1994) Br. J. Radiol. , vol.67 , pp. 2
    • Welch, M.E.1    Davy, T.J.2
  • 3
    • 33744696955 scopus 로고    scopus 로고
    • Improved beam edge conformity using an MLC shift technique
    • (1999) Med. Phys. , vol.26 , pp. 1098
    • Steinberg, T.1
  • 4
    • 0001738819 scopus 로고    scopus 로고
    • A high resolution collimating device - An affordable alternative to a micro-multileaf collimator
    • (1999) Med. Phys. , vol.26 , pp. 1096
    • Williams, P.1
  • 6
    • 33744638833 scopus 로고    scopus 로고
    • Microgradient intensity modulating multi-leaf collimator
    • U.S. Patent application 98E9142US
    • (1998)
    • Siochi, R.A.C.1
  • 9
    • 33744649048 scopus 로고    scopus 로고
    • The effects of beamlet size on IMRT optimization
    • The Use of Computers in Radiation Therapy XIIIth International Conference edited by W. Schlegel and T. Bortfeld (Springer-Verlag, Berlin, Heidelberg)
    • (2000) , pp. 305-307
    • Yi, B.1    Chen, Y.2    Boyer, A.3
  • 13
    • 0026753548 scopus 로고
    • Optimization by simulated annealing of three-dimensional, conformal treatment planning for radiation fields defined by a multileaf collimator: II. Inclusion of the two-dimensional modulation of the x-ray intensity
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1689-1704
    • Webb, S.1
  • 15
    • 0027249211 scopus 로고
    • A mathematical basis for selection of wedge angle and orientation
    • (1993) Med. Phys. , vol.20 , pp. 1211-1218
    • Sherouse, G.W.1
  • 18
    • 0030940761 scopus 로고    scopus 로고
    • An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery
    • (1997) Med. Phys. , vol.24 , pp. 857-886
    • Murphy, M.J.1
  • 19
    • 0002700387 scopus 로고    scopus 로고
    • Interventional strategies for reducing respiratory-induced motion in external beam therapy
    • The Use of Computers in Radiation Therapy, XIIIth International Conference, edited by W. Schlegel and T. Bortfeld (Springer-Verlag, Berlin, Heidelberg)
    • (2000) , pp. 514-516
    • Mageras, G.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.