-
5
-
-
0019409578
-
-
1981 ; 102:775-782.
-
Robicsek F, Tarjan P, Harbold NB Jr, Masters TN, Robicsek SA. Self-anchoring endocardia! pacemaker leads: current spectrum of types, advances in design, and clinical results. Am Heart J.1981 ; 102:775-782.
-
Tarjan P, Harbold NB Jr, Masters TN, Robicsek SA. Self-anchoring Endocardia! Pacemaker Leads: Current Spectrum of Types, Advances in Design, and Clinical Results. Am Heart J.
-
-
Robicsek, F.1
-
7
-
-
0027932703
-
-
1994; 17:1134-1142.
-
Frohlig G, Schwaab B, Schwerdt H, Lawall P, Trendelenburg M, Schieffer H. A new steroid-eluting screw-in electrode. Pacing Clin Electrophysiol.1994; 17:1134-1142.
-
Schwaab B, Schwerdt H, Lawall P, Trendelenburg M, Schieffer H. a New Steroid-eluting Screw-in Electrode. Pacing Clin Electrophysiol.
-
-
Frohlig, G.1
-
8
-
-
0028821712
-
-
1995:92:2935-2939.
-
Crossley GH, Brinker JA, Reynolds D, et al, Model 4068 Investigators. Steroid elution improves the stimulation threshold in an active-fixation atrial permanent pacing lead: a randomized, controlled study. Circulation.1995:92:2935-2939.
-
Brinker JA, Reynolds D, Et Al, Model 4068 Investigators. Steroid Elution Improves the Stimulation Threshold in an Active-fixation Atrial Permanent Pacing Lead: a Randomized, Controlled Study. Circulation.
-
-
Crossley, G.H.1
-
9
-
-
0028071593
-
-
1994:17:16651671.
-
Payne GE, Dunham DG, Rao AC, Crowther AP, Joseph SP, Skehan JD. Clinical experience with a new lead combining active fixation with steroid elution. Pacing Clin Electrophysiol.1994:17:16651671.
-
Dunham DG, Rao AC, Crowther AP, Joseph SP, Skehan JD. Clinical Experience with a New Lead Combining Active Fixation with Steroid Elution. Pacing Clin Electrophysiol.
-
-
Payne, G.E.1
-
10
-
-
0032799352
-
-
1999;22:1079-1081.
-
Glikson M, Hyberger LK, Hitzke MK, Kincaid DK, Hayes DL. Clinical surveillance of a lined, bipolar, J-shaped, steroid-eluting, silicone-insulated atrial pacing lead. Pacing Clin Electrophysiol.1999;22:1079-1081.
-
Hyberger LK, Hitzke MK, Kincaid DK, Hayes DL. Clinical Surveillance of a Lined, Bipolar, J-shaped, Steroid-eluting, Silicone-insulated Atrial Pacing Lead. Pacing Clin Electrophysiol.
-
-
Glikson, M.1
-
11
-
-
0029819773
-
-
1996; 19:14691473.
-
Glikson M, von Feldt LK, Suman VJ, Hayes DL. Short- and longterm results with an active-fixation, bipolar, polyurethane-insulated atrial pacing lead. Pacing Clin Electrophysiol,1996; 19:14691473.
-
Von Feldt LK, Suman VJ, Hayes DL. Short- and Longterm Results with an Active-fixation, Bipolar, Polyurethane-insulated Atrial Pacing Lead. Pacing Clin Electrophysiol
-
-
Glikson, M.1
-
12
-
-
0028142539
-
-
1994;17: 1399-1404.
-
Glikson M, von Feldt LK, Suman VJ, Hayes DL. Clinical surveillance of an active fixation, bipolar, polyurethane insulated pacing lead, part I: the atrial lead. Pacing Clin Electrophysiol.1994;17: 1399-1404.
-
Von Feldt LK, Suman VJ, Hayes DL. Clinical Surveillance of an Active Fixation, Bipolar, Polyurethane Insulated Pacing Lead, Part I: the Atrial Lead. Pacing Clin Electrophysiol.
-
-
Glikson, M.1
-
14
-
-
84900373712
-
-
1985:7582.
-
Dodinot B, Medeiros P, Galvao S. Tined or screw-in lead. In: Aubert AE, Ector H, eds. Pacemaker Leads: Proceedings. Amsterdam, the Netherlands: Elsevier Science Publishers;1985:7582.
-
Medeiros P, Galvao S. Tined or Screw-in Lead. In: Aubert AE, Ector H, Eds. Pacemaker Leads: Proceedings. Amsterdam, the Netherlands: Elsevier Science Publishers
-
-
Dodinot, B.1
|