Endothelial trauma due to intra-aortic balloon pump;Lesions endotheliales des ballons de contre-pulsion intra-aortique

Author keywords

Complications; Endothelium; Intra aortic balloon pumping

Indexed keywords

ANIMAL MODEL; AORTA BALLOON; AORTA INJURY; AORTA WALL; ARTICLE; ATHEROSCLEROTIC PLAQUE; CATTLE; HISTOLOGY; NONHUMAN; VASCULAR ENDOTHELIUM; ABDOMINAL AORTA; ANIMAL; DISEASE MODEL; INJURY; INSTRUMENTATION; PATHOLOGY;

EID: 0033658207     PISSN: 10239332     EISSN: None     Source Type: Journal    
DOI: 10.1024/1023-9332.6.2.80     Document Type: Article
Times cited : (2)

References (16)
  • 2
    • 0026934782 scopus 로고
    • Intraaortic balloon rupture: An increasing trend?
    • Alvarez JM, Brady PW, Mc Wilson R. Intraaortic balloon rupture: An increasing trend? ASA10 J 1992; 38:862-863.
    • (1992) ASA10 J , vol.38 , pp. 862-863
    • Alvarez, J.M.1    Brady, P.W.2    Mc Wilson, R.3
  • 3
    • 0020560005 scopus 로고
    • Comparison of wire-guided percutaneous insertion and conventional surgical insertion of intraaortic balloon pumps in 151 patients
    • Alcan KE, Stertzer SH, Wallsh E, Franzone AJ, Bruno MS, DePasquale NN. Comparison of wire-guided percutaneous insertion and conventional surgical insertion of intraaortic balloon pumps in 151 patients. Am J Med 1983; 75:24-28.
    • (1983) Am J Med , vol.75 , pp. 24-28
    • Alcan, K.E.1    Stertzer, S.H.2    Wallsh, E.3    Franzone, A.J.4    Bruno, M.S.5    Depasquale, N.N.6
  • 5
    • 0023733087 scopus 로고
    • Results of intraaortic balloon pumping after cardiac surgery: Experience with the Percor balloon catheter
    • Di Lello F, Mullen DC, Flemma RJ, Anderson AJ, Kleinman LH, Werner PH. Results of intraaortic balloon pumping after cardiac surgery: Experience with the Percor balloon catheter. Ann Thorac Surg 1988; 46:442Ā446.
    • (1988) Ann Thorac Surg , vol.46 , pp. 442-446
    • Di Lello, F.1    Mullen, D.C.2    Flemma, R.J.3    Anderson, A.J.4    Kleinman, L.H.5    Werner, P.H.6
  • 6
    • 0022631438 scopus 로고
    • Experience with intraaortic balloon counterpulsation
    • Sanfelippo PM, Baker NH, Ewy G et al. Experience with intraaortic balloon counterpulsation. Ann Thorac Surg 1986; 41:36-41.
    • (1986) Ann Thorac Surg , vol.41 , pp. 36-41
    • Sanfelippo, P.M.1    Baker, N.H.2    Ewy, G.3
  • 7
    • 0022606646 scopus 로고
    • Clinical experience with intraaortic balloon counterpulsation in 112 consecutive patients
    • Goldberger M, Tabak SW, Shah PK. Clinical experience with intraaortic balloon counterpulsation in 112 consecutive patients. Am Heart J 1986; 111:497-502.
    • (1986) Am Heart J , vol.111 , pp. 497-502
    • Goldberger, M.1    Tabak, S.W.2    Shah, P.K.3
  • 9
    • 0032170482 scopus 로고    scopus 로고
    • Morphometric analysis of heparin coated versus standard intra-aortic balloons
    • Mueller XM, Tevaearai HT, Hayoz D, von Segesser LK. Morphometric analysis of heparin coated versus standard intra-aortic balloons ASAIO J 1998; 44:M401-M404.
    • (1998) ASAIO J , vol.44
    • Mueller, X.M.1    Tevaearai, H.T.2    Hayoz, D.3    Von Segesser, L.K.4
  • 10
    • 0033000710 scopus 로고    scopus 로고
    • Thrombo-genicity of deflated intraaortic balloon: Impact of heparin coating
    • Mueller XM, Tevaearai HT, Hayoz D, von Segesser LK. Thrombo-genicity of deflated intraaortic balloon: Impact of heparin coating. Artif Org 1999; 23:195-198.
    • (1999) Artif Org , vol.23 , pp. 195-198
    • Mueller, X.M.1    Tevaearai, H.T.2    Hayoz, D.3    Von Segesser, L.K.4
  • 13
    • 0028244084 scopus 로고
    • The hostile environment of the aging human aorta and the smaller patient - Their implications for the intra-aortic balloon
    • Wolvek S. The hostile environment of the aging human aorta and the smaller patient - their implications for the intra-aortic balloon. Perfusion 1994; 9:87-94.
    • (1994) Perfusion , vol.9 , pp. 87-94
    • Wolvek, S.1
  • 16
    • 0019738103 scopus 로고
    • Analysis of longest intra-aortic balloon implant in human patient (327 days)
    • Asher B, Turcotte CR. Analysis of longest intra-aortic balloon implant in human patient (327 days). Trans Amer Soc Artif Intern Organs 1981; 27:372-379.
    • (1981) Trans Amer Soc Artif Intern Organs , vol.27 , pp. 372-379
    • Asher, B.1    Turcotte, C.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.