메뉴 건너뛰기




Volumn 110, Issue 12, 2000, Pages 2135-2142

Effect of mechanical reinforcement on stability of the rotary door flap laryngotracheal reconstruction: A canine study

Author keywords

Laryngotracheal reconstruction; Laryngotracheal stenosis; Rotary door flap; Sternohyoid muscle

Indexed keywords

CEMENT; HYDROXYAPATITE; POLYETHYLENE; TITANIUM;

EID: 0033634706     PISSN: 0023852X     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005537-200012000-00031     Document Type: Article
Times cited : (4)

References (31)
  • 3
    • 4243765319 scopus 로고
    • Reconstructive surgery of the larynx and laryngeal part of the pharynx
    • Hinchliffe R, ed. Scientific Foundations of Otolaryngology. Chicago: W. Heinemann Medical Publication
    • (1976) , pp. 894-919
    • Ogura, J.H.1    Spector, G.H.2
  • 12
    • 85037803317 scopus 로고
    • Adhesion of bone to titanium
    • Biological and biomechanical performance of biomaterials. Proceedings of the Fifth European Conference on Biomaterials; Paris, France; September
    • (1985)
    • Steinemann, S.1
  • 25
    • 0023767227 scopus 로고
    • Use of stents in laryngotracheal reconstruction in children: Indications, technical considerations, and complications
    • (1988) Laryngoscope , vol.98 , pp. 849-854
    • Zalzal, G.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.