메뉴 건너뛰기




Volumn 15, Issue 1, 2000, Pages 111-118

Measurement of Misfit at the Implant-Prosthesis Interface: An Experimental Method Using a Coordinate Measuring Machine

Author keywords

Coordinate measuring machine; Datum plane; Framework; Implant

Indexed keywords

ARTICLE; COMPARATIVE STUDY; DENTURE; HUMAN; NONPARAMETRIC TEST; PROSTHESIS; STANDARD; STATISTICAL ANALYSIS; STATISTICS; TOOTH PROSTHESIS;

EID: 0033631081     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (29)
  • 3
    • 0023304661 scopus 로고
    • The Swedish system of osseointegrated implants: Problems and complications encountered during a four-year period
    • Worthington P, Bolender CL, Taylor TD. The Swedish system of osseointegrated implants: Problems and complications encountered during a four-year period. Int J Oral Maxillofac Implants 1987;2:77-84.
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 77-84
    • Worthington, P.1    Bolender, C.L.2    Taylor, T.D.3
  • 4
    • 0347666945 scopus 로고
    • The importance of passive fit
    • Jorneus L. The importance of passive fit. Nobelpharma News 1991;5:2.
    • (1991) Nobelpharma News , vol.5 , pp. 2
    • Jorneus, L.1
  • 5
    • 0029439074 scopus 로고
    • Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit
    • Clelland NL, Papazoglou E, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit. J Prosthodont 1995;4:243-250.
    • (1995) J Prosthodont , vol.4 , pp. 243-250
    • Clelland, N.L.1    Papazoglou, E.2    Carr, A.B.3    Gilat, A.4
  • 6
    • 0029688806 scopus 로고    scopus 로고
    • Inaccurate fit of implant superstructures. Part 2: Efficacy of the Preci-disc system for the correction of errors
    • Uludamar A, Leung T. Inaccurate fit of implant superstructures. Part 2: Efficacy of the Preci-disc system for the correction of errors. Int J Prosthodont 1996;9:16-20.
    • (1996) Int J Prosthodont , vol.9 , pp. 16-20
    • Uludamar, A.1    Leung, T.2
  • 8
    • 0345774954 scopus 로고
    • Built-in strain and untoward forces are the inevitable companions of prosthetic misfit
    • Carlsson L. Built-in strain and untoward forces are the inevitable companions of prosthetic misfit. Nobelpharma News 1994;8:5.
    • (1994) Nobelpharma News , vol.8 , pp. 5
    • Carlsson, L.1
  • 9
    • 0029185973 scopus 로고
    • The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit?
    • Tan KB. The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit? Ann Acad Med Singapore 1995;24:138-157.
    • (1995) Ann Acad Med Singapore , vol.24 , pp. 138-157
    • Tan, K.B.1
  • 10
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 11
    • 0029353514 scopus 로고
    • Implant prosthodontic treatment options for the edentulous patient
    • Zarb GA, Schmitt A. Implant prosthodontic treatment options for the edentulous patient. J Oral Rehabil 1995;22: 653-660.
    • (1995) J Oral Rehabil , vol.22 , pp. 653-660
    • Zarb, G.A.1    Schmitt, A.2
  • 13
    • 0024893746 scopus 로고
    • The biologic width-periodontal-restorative relationship
    • Kamin S. The biologic width-periodontal-restorative relationship. Singapore Dent J 1989;14(1):13-15.
    • (1989) Singapore Dent J , vol.14 , Issue.1 , pp. 13-15
    • Kamin, S.1
  • 14
    • 0142167826 scopus 로고
    • Mobility characteristics and tactile sensitivity of osseointegrated fixture-system
    • Van Steenberghe D (ed). Tissue Integration in Oral and Maxillofacial Reconstruction. May 1985, Brussels. Amsterdam: Elsevier Science Publishers
    • Sekine H, Komiyoma Y, Hotta H, Yoshida K. Mobility characteristics and tactile sensitivity of osseointegrated fixture-system. In: Van Steenberghe D (ed). Tissue Integration in Oral and Maxillofacial Reconstruction. Proceedings of an International Congress, May 1985, Brussels. Amsterdam: Elsevier Science Publishers, 1986:326-332.
    • (1986) Proceedings of an International Congress , pp. 326-332
    • Sekine, H.1    Komiyoma, Y.2    Hotta, H.3    Yoshida, K.4
  • 15
    • 0029377214 scopus 로고
    • Accuracy of implant-supported prostheses in the edentulous jaw: Analysis of precision of fit between the gold-alloy frameworks and mastercasts by means of a 3-D photogrammetric technique
    • Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw: Analysis of precision of fit between the gold-alloy frameworks and mastercasts by means of a 3-D photogrammetric technique. Clin Oral Implants Res 1995;6: 172-180.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 172-180
    • Jemt, T.1    Lie, A.2
  • 16
    • 0021776981 scopus 로고
    • Design of superstructures for osseointegrated fixtures
    • Klineberg IJ, Murray GM. Design of superstructures for osseointegrated fixtures. Swed Dent J 1985;28(suppl):63-69.
    • (1985) Swed Dent J , vol.28 , Issue.SUPPL. , pp. 63-69
    • Klineberg, I.J.1    Murray, G.M.2
  • 17
    • 0023281958 scopus 로고
    • Rehabilitation of the edentulous mandible with a tissue-integrated fixed prosthesis: A six-year longitudinal study
    • Lindqvist L, Carlsson GE, Glantz PO. Rehabilitation of the edentulous mandible with a tissue-integrated fixed prosthesis: A six-year longitudinal study. Quintessence Int 1987;18: 89-96.
    • (1987) Quintessence Int , vol.18 , pp. 89-96
    • Lindqvist, L.1    Carlsson, G.E.2    Glantz, P.O.3
  • 18
  • 21
    • 0030237874 scopus 로고    scopus 로고
    • Prosthesis misfit and marginal bone loss in edentulous implant patients
    • Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-625.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 620-625
    • Jemt, T.1    Book, K.2
  • 22
    • 0017496465 scopus 로고
    • The measurement of distortion: Theoretical considerations
    • Nicholls JI. The measurement of distortion: Theoretical considerations. J Prosthet Dent 1977;37:339-343.
    • (1977) J Prosthet Dent , vol.37 , pp. 339-343
    • Nicholls, J.I.1
  • 23
    • 0027623331 scopus 로고
    • Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses
    • Tan KB, Rubenstein JE, Nicholls IE, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont 1993;6:346-363.
    • (1993) Int J Prosthodont , vol.6 , pp. 346-363
    • Tan, K.B.1    Rubenstein, J.E.2    Nicholls, I.E.3    Yuodelis, R.A.4
  • 24
    • 0028390303 scopus 로고
    • Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures
    • Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res 1994;5:30-36.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 30-36
    • Lie, A.1    Jemt, T.2
  • 25
    • 0029351262 scopus 로고
    • Three dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations
    • Jemt T. Three dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil 1995;22:549-556.
    • (1995) J Oral Rehabil , vol.22 , pp. 549-556
    • Jemt, T.1
  • 26
    • 0030237874 scopus 로고    scopus 로고
    • Prosthesis misfit and marginal bone loss in edentulous implant patients
    • Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-625.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 620-625
    • Jemt, T.1    Book, K.2
  • 27
    • 0030097958 scopus 로고    scopus 로고
    • In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw
    • Jemt T. In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996;11:151-158.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 151-158
    • Jemt, T.1
  • 28
    • 0346478930 scopus 로고
    • A new MS-DOS based integrated package for triangulation and data collection for close range applications
    • Commission V
    • Hinsken L, Cogan L, Kotowski R. A new MS-DOS based integrated package for triangulation and data collection for close range applications. Int Arch Photogrammetry Remote Sensing 1992;29 (Part B 5, Commission V):11-18.
    • (1992) Int Arch Photogrammetry Remote Sensing , vol.29 , Issue.5 PART B , pp. 11-18
    • Hinsken, L.1    Cogan, L.2    Kotowski, R.3
  • 29
    • 0026953052 scopus 로고
    • Accuracy of the acrylic resin pattern for the implant-retained prosthesis
    • Ness E, Nicholls J, Rubenstein J, Smith D. Accuracy of the acrylic resin pattern for the implant-retained prosthesis. Int J Prosthodont 1992;5:542-549.
    • (1992) Int J Prosthodont , vol.5 , pp. 542-549
    • Ness, E.1    Nicholls, J.2    Rubenstein, J.3    Smith, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.