메뉴 건너뛰기




Volumn 27, Issue 3, 2000, Pages 173-178

Comparison of a T2* w. 3D CISS and a T2 w. 3D turbo spin echo sequence for the anatomical study of facial and vestibulocochlear nerves

Author keywords

3d gradient echo sequence; 3D turbo spin echo sequence; Anatomy; Facial nerve; Magnetic Resonance Imaging; MRI; Vestibulocochlear nerve

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC PROCEDURE; FACIAL NERVE; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; INTERNAL AUDITORY CANAL; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PONS ANGLE; VESTIBULOCOCHLEAR NERVE; ADOLESCENT; AGE; COMPARATIVE STUDY; HISTOLOGY; IMAGE PROCESSING; METHODOLOGY; MIDDLE AGED; SEX DIFFERENCE;

EID: 0033625987     PISSN: 01509861     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (22)

References (19)
  • 4
    • 0000278835 scopus 로고
    • Constructive Interference in steady state for motion sensitivity reduction
    • Book of Abstracts, Society of Magnetic Resonance in Medicine, Berkeley
    • (1989) , vol.1 , pp. 642
    • Deimling, M.1    Laub, G.A.2
  • 12
    • 0032612899 scopus 로고    scopus 로고
    • MR imaging: Acronyms and clinical applications
    • (1999) Eur Radiol , vol.9 , pp. 979-997
    • Nitz, W.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.