메뉴 건너뛰기




Volumn 28, Issue 3-4, 2000, Pages 457-461

Improved orthopaedic bone cement formulations based on rubber toughening

Author keywords

Acrylic; Fracture toughness; Hip arthroplasty; Poly(methylmethacrylate)

Indexed keywords

ACRYLIC CEMENT; BONE CEMENT; POLY(METHYL METHACRYLATE); RUBBER;

EID: 0033622591     PISSN: 0278940X     EISSN: None     Source Type: Journal    
DOI: 10.1615/CritRevBiomedEng.v28.i34.180     Document Type: Conference Paper
Times cited : (9)

References (12)
  • 1
    • 0000206228 scopus 로고
    • Bonding of prosthesis to bone by cement
    • Charnely, J., Bonding of prosthesis to bone by cement, J. Bone Joint Surg., 46b, 518, 1964.
    • (1964) J. Bone Joint Surg. , vol.46 B , pp. 518
    • Charnely, J.1
  • 2
    • 0019962848 scopus 로고
    • A ten year follow-up of one hundred consecutive Muller curved-stem total hip replacement arthroplasties
    • Sutherland, C. J., Wilde, A. H., Borden, L. S., and Marks, K. E., A ten year follow-up of one hundred consecutive Muller curved-stem total hip replacement arthroplasties, J. Bone Joint Surg., 64A, 970, 1982.
    • (1982) J. Bone Joint Surg. , vol.64 A , pp. 970
    • Sutherland, C.J.1    Wilde, A.H.2    Borden, L.S.3    Marks, K.E.4
  • 3
    • 0019981269 scopus 로고
    • Ten year follow-up study of total hip replacement
    • Stauffer, R. N., Ten year follow-up study of total hip replacement, J. Bone Joint Surg., 64A, 983, 1982.
    • (1982) J. Bone Joint Surg. , vol.64 A , pp. 983
    • Stauffer, R.N.1
  • 5
    • 0007105740 scopus 로고
    • Ph.D. Dissertation, Department of Biomedical Engineering, University of Alabama at Birmingham
    • Moseley, J., Ph.D. Dissertation, Department of Biomedical Engineering, University of Alabama at Birmingham, 1992.
    • (1992)
    • Moseley, J.1
  • 6
    • 0031573492 scopus 로고    scopus 로고
    • The development and characterization of a fracture toughened acrylic for luting total joint arthroplasties
    • Moseley, J. P., Lemons, J. K., and Mays, J. W., The development and characterization of a fracture toughened acrylic for luting total joint arthroplasties, J. Biomed. Mater. Res., 47(4), 529, 1999.
    • (1999) J. Biomed. Mater. Res. , vol.47 , Issue.4 , pp. 529
    • Moseley, J.P.1    Lemons, J.K.2    Mays, J.W.3
  • 7
    • 0022478003 scopus 로고
    • Uncemented two-component femoral prosthesis for the hip joint
    • Hansen, L. B., Kroman, B., and Baekgaard, N., Uncemented two-component femoral prosthesis for the hip joint, Clin. Orthop. Rel. Res., 206, 182, 1986.
    • (1986) Clin. Orthop. Rel. Res. , vol.206 , pp. 182
    • Hansen, L.B.1    Kroman, B.2    Baekgaard, N.3
  • 10
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante, J., Rostoker, W., Lueck, R., and Ray, R. D., Sintered fiber metal composites as a basis for attachment of implants to bone, J. Bone Joint Surg., 53A, 101, 1971.
    • (1971) J. Bone Joint Surg. , vol.53 A , pp. 101
    • Galante, J.1    Rostoker, W.2    Lueck, R.3    Ray, R.D.4
  • 12
    • 0022034099 scopus 로고
    • Bioglass coatings and bioglass composites as implant materials
    • Ducheyne, P., Bioglass coatings and bioglass composites as implant materials, J. Biomed. Mater. Res., 19, 273, 1985.
    • (1985) J. Biomed. Mater. Res. , vol.19 , pp. 273
    • Ducheyne, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.