메뉴 건너뛰기




Volumn 89, Issue 1, 2000, Pages 43-50

Initial experience with an implantable loop recorder in patients with unexplained syncope;Erste erfahrungen uber den diagnostischen nutzen eines implantierbaren langzeit-ereignisrekorders (endless-loop-rekorder, REVEAL(R)) bei patienten mit unklaren synkopen

Author keywords

Implantable device; Loop recorder; Syncope

Indexed keywords

ADULT; AGED; AMBULATORY MONITORING; ARTICLE; BRADYCARDIA; CLINICAL ARTICLE; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY MONITORING; ELECTRODE; FEMALE; FOLLOW UP; HEART ARRHYTHMIA; HUMAN; IMPLANTATION; MALE; RECURRENT DISEASE; SYNCOPE; TACHYCARDIA; CORONARY ARTERY DISEASE; DIFFERENTIAL DIAGNOSIS; ELECTROCARDIOGRAPHY; EQUIPMENT DESIGN; HEART LEFT VENTRICLE FUNCTION; HYPERTENSION; INSTRUMENTATION; LONG TERM CARE; MIDDLE AGED; PROSTHESES AND ORTHOSES;

EID: 0033621968     PISSN: 03005860     EISSN: None     Source Type: Journal    
DOI: 10.1007/s003920050007     Document Type: Article
Times cited : (7)

References (25)
  • 1
    • 0020586423 scopus 로고
    • Role of clinical electrophysiologic studies in patients with unexplained recurrent syncope
    • 1. Akthar M, Shenasar M, Denker S, Gilbert CJ, Rizuri L (1983) Role of clinical electrophysiologic studies in patients with unexplained recurrent syncope. PACE 6: 192-201
    • (1983) PACE , vol.6 , pp. 192-201
    • Akthar, M.1    Shenasar, M.2    Denker, S.3    Gilbert, C.J.4    Rizuri, L.5
  • 2
    • 0021284306 scopus 로고
    • Utility of electrophysiologic studies in the management of tachycardia, sudden death and syncope
    • 2. Bardy GH, Packer DL, Germann LD, Gallagher JJ (1984) Utility of electrophysiologic studies in the management of tachycardia, sudden death and syncope. Ann NY Acad Sci 427:16-39
    • (1984) Ann NY Acad Sci , vol.427 , pp. 16-39
    • Bardy, G.H.1    Packer, D.L.2    Germann, L.D.3    Gallagher, J.J.4
  • 3
    • 0023816310 scopus 로고
    • Long-term prognosis of patients undergoing electrophysiologic studies for syncope of unknown origin
    • 3. Bass EB, Elson JJ, Fogors RN, Petersen J, Arena VC, Kapoor WN (1988) Long-term prognosis of patients undergoing electrophysiologic studies for syncope of unknown origin. Am J Cardiol 62:1186-1191
    • (1988) Am J Cardiol , vol.62 , pp. 1186-1191
    • Bass, E.B.1    Elson, J.J.2    Fogors, R.N.3    Petersen, J.4    Arena, V.C.5    Kapoor, W.N.6
  • 4
    • 0023178157 scopus 로고
    • Detection of arrhythmias: Use of a patient-activated ambulatory electrocardiogram device with a solid state memory loop
    • 4. Brown AP, Dawkins KD, Davies JG (1987) Detection of arrhythmias: use of a patient-activated ambulatory electrocardiogram device with a solid state memory loop. Br Heart J 58:251-253
    • (1987) Br Heart J , vol.58 , pp. 251-253
    • Brown, A.P.1    Dawkins, K.D.2    Davies, J.G.3
  • 5
    • 0018857209 scopus 로고
    • Arrhythmias detected by ambulatory monitoring: Lack of correlation with symptoms of dizziness and syncope
    • 5. Clark PI, Glasser SO, Spoto E (1980) Arrhythmias detected by ambulatory monitoring: lack of correlation with symptoms of dizziness and syncope. Chest 77:722-725
    • (1980) Chest , vol.77 , pp. 722-725
    • Clark, P.I.1    Glasser, S.O.2    Spoto, E.3
  • 6
    • 0019943760 scopus 로고
    • Evaluation and outcome of emergency room patients with transient loss of consciousness
    • 6. Day SC, Cook EF, Funkenstein H, Goldman L (1982) Evaluation and outcome of emergency room patients with transient loss of consciousness. Am J Med 73:15-23
    • (1982) Am J Med , vol.73 , pp. 15-23
    • Day, S.C.1    Cook, E.F.2    Funkenstein, H.3    Goldman, L.4
  • 7
    • 0026504448 scopus 로고
    • Electrophysiologic studies in patients with unexplained syncope
    • 7. Dennis AR, Ross DL, Richards DA, Uther JB (1992) Electrophysiologic studies in patients with unexplained syncope. Int J Cardiol 35:211-217
    • (1992) Int J Cardiol , vol.35 , pp. 211-217
    • Dennis, A.R.1    Ross, D.L.2    Richards, D.A.3    Uther, J.B.4
  • 8
    • 0025345481 scopus 로고
    • Use of ambulatory electrocardiographic (Holter) monitoring
    • 8. DiMarco JP, Philbrick JT (1990) Use of ambulatory electrocardiographic (Holter) monitoring. Ann J Med 113:53-68
    • (1990) Ann J Med , vol.113 , pp. 53-68
    • DiMarco, J.P.1    Philbrick, J.T.2
  • 9
    • 0021333079 scopus 로고
    • Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
    • 9. Gibson TC, Heitzman MR (1984) Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope. Am J Cardiol 53:1013-1017
    • (1984) Am J Cardiol , vol.53 , pp. 1013-1017
    • Gibson, T.C.1    Heitzman, M.R.2
  • 11
    • 0020530694 scopus 로고
    • A prospective evaluation and follow-up of patients with syncope
    • 11. Kapoor WN, Karpf M, Wieand S, Peterson JR, et al (1983) A prospective evaluation and follow-up of patients with syncope. N Engl J Med 309:197-207
    • (1983) N Engl J Med , vol.309 , pp. 197-207
    • Kapoor, W.N.1    Karpf, M.2    Wieand, S.3    Peterson, J.R.4
  • 12
    • 0026803414 scopus 로고
    • Evaluation and management of the patient with syncope
    • 12. Kapoor WN (1992) Evaluation and management of the patient with syncope. JAMA 268:2553-2560
    • (1992) JAMA , vol.268 , pp. 2553-2560
    • Kapoor, W.N.1
  • 13
    • 0025294155 scopus 로고
    • Evaluation and outcome of patients with syncope
    • 13. Kapoor WN (1990) Evaluation and outcome of patients with syncope. Medicine 69:160-175
    • (1990) Medicine , vol.69 , pp. 160-175
    • Kapoor, W.N.1
  • 14
    • 0029120382 scopus 로고
    • The etiology of syncope in patients with negative tilt-table-test and electrophysiological testing
    • 14. Krahn AD, Klein GJ, Norris C, Yee R (1995) The etiology of syncope in patients with negative tilt-table-test and electrophysiological testing. Circulation 92,7: 1819-1824
    • (1995) Circulation , vol.92 , Issue.7 , pp. 1819-1824
    • Krahn, A.D.1    Klein, G.J.2    Norris, C.3    Yee, R.4
  • 15
    • 0032943618 scopus 로고    scopus 로고
    • Utility of an extended monitoring strategy in patients with problematic syncope
    • 15. Krahn DA, Klein GJ, Yee R, Newhouse TT, Norris C, for the Reveal Investigators (1999) Utility of an extended monitoring strategy in patients with problematic syncope. Circulation 99:406-410
    • (1999) Circulation , vol.99 , pp. 406-410
    • Krahn, D.A.1    Klein, G.J.2    Yee, R.3    Newhouse, T.T.4    Norris, C.5
  • 16
    • 0024364594 scopus 로고
    • Natural history of patients with unexplained syncope and a nondiagnostic electrophysiologic study
    • 16. Kushner JA, Kou WH, Kadish AH, Morady F (1989) Natural history of patients with unexplained syncope and a nondiagnostic electrophysiologic study. J Am Coll Cardiol 14:391-396
    • (1989) J Am Coll Cardiol , vol.14 , pp. 391-396
    • Kushner, J.A.1    Kou, W.H.2    Kadish, A.H.3    Morady, F.4
  • 17
    • 0025279107 scopus 로고
    • Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
    • 17. Linzer M, Pritchett EL, Pontinen M, McCarthy E, Divine GW (1990) Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope. Am J Cardiol 66:214-219
    • (1990) Am J Cardiol , vol.66 , pp. 214-219
    • Linzer, M.1    Pritchett, E.L.2    Pontinen, M.3    McCarthy, E.4    Divine, G.W.5
  • 18
    • 0023485125 scopus 로고
    • Syncope
    • 18. Linzer M (1987) Syncope. South Med J 80:545-552
    • (1987) South Med J , vol.80 , pp. 545-552
    • Linzer, M.1
  • 21
    • 0025975792 scopus 로고
    • Electrophysiologic evaluation and outcome of patients with syncope of unknown origin
    • 21. Muller T, Roy D, Talajic M, Lemery R, Nattel S, Cassidy D (1991) Electrophysiologic evaluation and outcome of patients with syncope of unknown origin. Eur Heart J 12:139-143
    • (1991) Eur Heart J , vol.12 , pp. 139-143
    • Muller, T.1    Roy, D.2    Talajic, M.3    Lemery, R.4    Nattel, S.5    Cassidy, D.6
  • 23
    • 0026425132 scopus 로고
    • Unexplained syncope evaluated by electrophysiologic studies and head-up tilt-testing
    • 23. Sra JS, Anderson AJ, Sheikh SH, et al (1991) Unexplained syncope evaluated by electrophysiologic studies and head-up tilt-testing. Ann Intern Med 114:1013-1019
    • (1991) Ann Intern Med , vol.114 , pp. 1013-1019
    • Sra, J.S.1    Anderson, A.J.2    Sheikh, S.H.3
  • 24
    • 0022191549 scopus 로고
    • The value of electrophysiologic studies in syncope of undetermined origin
    • 24. Teichman SL, Felder SD, Matos JA, Kim SG, Fisher JD (1985) The value of electrophysiologic studies in syncope of undetermined origin. Am Heart J 110:469-479
    • (1985) Am Heart J , vol.110 , pp. 469-479
    • Teichman, S.L.1    Felder, S.D.2    Matos, J.A.3    Kim, S.G.4    Fisher, J.D.5
  • 25
    • 0001685231 scopus 로고
    • The role of electrophysiologic studies in the evaluation of recurrent, unexplained syncope
    • 25. Westveer DC, Stuart J, Vandam D, Gordon J, Timmis GC (1984) The role of electrophysiologic studies in the evaluation of recurrent, unexplained syncope. Cardiovasc Rev Rep 5:770-780
    • (1984) Cardiovasc Rev Rep , vol.5 , pp. 770-780
    • Westveer, D.C.1    Stuart, J.2    Vandam, D.3    Gordon, J.4    Timmis, G.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.