메뉴 건너뛰기




Volumn 161, Issue 4, 1999, Pages 436-438

Pacemaker failure following transthoracic DC cardioversion;Pacemakersvigt ved elektiv DC-konvertering af atrial takykardi

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; BRADYCARDIA; CARDIOVERSION; CASE REPORT; ELECTROCARDIOGRAPHY; EQUIPMENT; FEMALE; HUMAN; PATHOPHYSIOLOGY; SUPRAVENTRICULAR TACHYCARDIA;

EID: 0033601539     PISSN: 00415782     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 0014465357 scopus 로고
    • Protection of implanted pacemakers from excessive electrical energy of D.C. Shock
    • Lau FYK, Bilitch M, Wintroub HJ. Protection of implanted pacemakers from excessive electrical energy of D.C. shock. Am J Cardiol 1969; 23: 244-9.
    • (1969) Am J Cardiol , vol.23 , pp. 244-249
    • Lau, F.Y.K.1    Bilitch, M.2    Wintroub, H.J.3
  • 2
    • 0018750658 scopus 로고
    • Complications of defibrillation with permanent pacemaker in situ
    • Aylward P, Blood R, Tonkin A. Complications of defibrillation with permanent pacemaker in situ. PACE 1979; 2: 462-4.
    • (1979) PACE , vol.2 , pp. 462-464
    • Aylward, P.1    Blood, R.2    Tonkin, A.3
  • 4
    • 0020638202 scopus 로고
    • Adverse acute and chronic effects of electrical defibrillation and cardioversion on implanted unipolar cardiac pacing systems
    • Levine PA, Barold SS, Fletcher RD, Talbot P. Adverse acute and chronic effects of electrical defibrillation and cardioversion on implanted unipolar cardiac pacing systems. J Am Coll Cardiol 1983; 1: 1413-22.
    • (1983) J Am Coll Cardiol , vol.1 , pp. 1413-1422
    • Levine, P.A.1    Barold, S.S.2    Fletcher, R.D.3    Talbot, P.4
  • 5
    • 0025732925 scopus 로고
    • Pacemaker failure on induction of anaesthesia
    • Finfer SR. Pacemaker failure on induction of anaesthesia. Br J Anaesth 1991; 66: 509-12.
    • (1991) Br J Anaesth , vol.66 , pp. 509-512
    • Finfer, S.R.1
  • 6
    • 0027119201 scopus 로고
    • Pacemakersvigt ved elektrisk kardiovertering af atrieflimren
    • Nielsen-Kusk JE, Pedersen CM, Thomsen PEB. Pacemakersvigt ved elektrisk kardiovertering af atrieflimren. Ugeskr Læger 1992; 154: 2571-2.
    • (1992) Ugeskr Læger , vol.154 , pp. 2571-2572
    • Nielsen-Kusk, J.E.1    Pedersen, C.M.2    Thomsen, P.E.B.3
  • 7
    • 0028798688 scopus 로고
    • Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients
    • Altamura G, Bianconi L, Bianco FL, Toscano S, Ammirati F, Pandozi C et al. Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients. PACE 1995; 18: 194-8.
    • (1995) PACE , vol.18 , pp. 194-198
    • Altamura, G.1    Bianconi, L.2    Bianco, F.L.3    Toscano, S.4    Ammirati, F.5    Pandozi, C.6
  • 8
    • 0024267298 scopus 로고
    • Increased pacing threshold after an automatic defibrillator shock in dogs: Effects of class I and class II antiarrhythmic drugs
    • Guarnieri T, Datorre SD. Bondke H, Brinker J, Myers S, Levine JH. Increased pacing threshold after an automatic defibrillator shock in dogs: Effects of class I and class II antiarrhythmic drugs. PACE 1988; 11: 1324-30.
    • (1988) PACE , vol.11 , pp. 1324-1330
    • Guarnieri, T.1    Datorre, S.D.2    Bondke, H.3    Brinker, J.4    Myers, S.5    Levine, J.H.6
  • 9
    • 0026543433 scopus 로고
    • Interference by antiarrhythmic agents with function of electrical cardiac devices
    • Tworek DA, Nazari J, Ezri M, Bauman JL. Interference by antiarrhythmic agents with function of electrical cardiac devices. Clin Pharm 1992; 11: 48-56.
    • (1992) Clin Pharm , vol.11 , pp. 48-56
    • Tworek, D.A.1    Nazari, J.2    Ezri, M.3    Bauman, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.