메뉴 건너뛰기




Volumn 40, Issue 17, 1999, Pages 3293-3296

An efficient asymmetric catalytic hydrogenation of 4-aryl coumarins, preparation of a key intermediate in the synthesis of a class of endothelin receptor antagonists

Author keywords

[No Author keywords available]

Indexed keywords

3 (2 CARBOXYMETHOXY 4 METHOXYPHENYL) 1 (3,4 METHYLENEDIOXYPHENYL) 5 PROPOXY 2 INDANCARBOXYLIC ACID; COUMARIN DERIVATIVE; ENDOTHELIN RECEPTOR ANTAGONIST; ENRASENTAN;

EID: 0033597255     PISSN: 00404039     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0040-4039(99)00478-5     Document Type: Article
Times cited : (52)

References (25)
  • 2
    • 85069422561 scopus 로고    scopus 로고
    • manuscript in preparation
    • 2. Jeffery L. Wood; manuscript in preparation.
    • Wood, J.L.1
  • 6
    • 0002091136 scopus 로고
    • 4. 2 could be synthesized via the Pechmann condensation of 3-methoxyphenol and 3-oxo-3-propoxy-benzenepropanoic acid. Sethna, S.; Phadke, R. Organic Reactions 1953, 7, 1.
    • (1953) Organic Reactions , vol.7 , pp. 1
    • Sethna, S.1    Phadke, R.2
  • 13
    • 85069420992 scopus 로고    scopus 로고
    • Purchased from Aldrich
    • 6. Purchased from Aldrich.
  • 18
    • 85069425212 scopus 로고    scopus 로고
    • note
    • 3) δ 10.56, 22.60, 55.32, 69.53, 101.21, 106.75, 113.61, 114.49, 116.17, 119.59, 120.16, 129.65, 131.14, 141.40, 145.20, 154.34, 159.41, 160.80.
  • 20
    • 85069422854 scopus 로고    scopus 로고
    • note
    • 1H NMR for evidence of hydrogenation. The maleic acid procedure was repeated until no hydrogenation was observed.
  • 21
    • 85069423323 scopus 로고    scopus 로고
    • note
    • 14. The progress of the hydrogenation and subsequent transformations could be followed by chromatographic analysis using an HP Hypersil ODS column (5 μ, 200 x 4.6 mm) with 60:40:0.1 acetonitrile:water:acetic acid as eluent at a flow rate of 1.0 mL/min and detection at 230 nm. The following retention times were observed: 2-16.3 min, 1-12.6 min, 3-4.6 min, 4-4.2 min.
  • 22
    • 85069424194 scopus 로고    scopus 로고
    • note
    • 15. The enantiomeric excess of 1 was determined by chromatographic analysis on a Chiralpak AD column (Chiral Technologies) using 95:5 hexane:2-propanol as the mobile phase at a flow rate of 1.0 mL/min and detection at 275 nm. The retention times of 1 (S-isomer) and 1 (R-isomer) were 12.6 min and 11.4 min respectively.
  • 23
    • 85069422720 scopus 로고    scopus 로고
    • note
    • 13 100 mL stainless steel autoclave was charged with 2 (7.75 g, 25.0 mmol), abs. methanol (69 mL), 4 N NaOH (12.5 mL, 50.0 mmol, 2 eq) and one of the following catalyst systems: a) [(S)-BINAP(p-cymene)(Cl) Ru]Cl (325 mg, 0.35 mmol, 1.4%);
  • 24
    • 85069426659 scopus 로고    scopus 로고
    • note
    • 4 (36 mg, 0.05 mmol, 0.2%);
  • 25
    • 85069419382 scopus 로고    scopus 로고
    • note
    • -1.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.