-
1
-
-
0028926798
-
Optimal truncation of defibrillation pulses
-
Irnich W. Optimal truncation of defibrillation pulses. Pacing Clin Electrophysiol. 1995;18:1:673-688.
-
(1995)
Pacing Clin Electrophysiol
, vol.18
, Issue.1
, pp. 673-688
-
-
Irnich, W.1
-
2
-
-
0345310058
-
Influence of phase duration of biphasic waveforms on defibrillation energy requirements with a 70 μF capacitance
-
Schauerte P, Schöndube FA, Grossmann M, Dörge H, Stein F, Dohmen B, Moumen A, Erena K, Messmer BJ, Hanrath P, Stellbrink C. Influence of phase duration of biphasic waveforms on defibrillation energy requirements with a 70 μF capacitance. Circulation. 1998;97:2073-2078.
-
(1998)
Circulation
, vol.97
, pp. 2073-2078
-
-
Schauerte, P.1
Schöndube, F.A.2
Grossmann, M.3
Dörge, H.4
Stein, F.5
Dohmen, B.6
Moumen, A.7
Erena, K.8
Messmer, B.J.9
Hanrath, P.10
Stellbrink, C.11
-
3
-
-
0029101266
-
Defibrillation thresholds are lower with smaller storage capacitors
-
Leonelli FM, Kroll MW, Brewer JE. Defibrillation thresholds are lower with smaller storage capacitors. Pacing Clin Electrophysiol. 1995;18: 1661-1665.
-
(1995)
Pacing Clin Electrophysiol
, vol.18
, pp. 1661-1665
-
-
Leonelli, F.M.1
Kroll, M.W.2
Brewer, J.E.3
-
4
-
-
0028850822
-
A prospective randomized comparison in humans of biphasic waveform 60-μF and 120-μF capacitance pulses using a unipolar defibrillation system
-
Bardy GH, Poole JE, Kudenchuk PJ, Dolack GL, Mehra R, DeGroot P, Raitt MH, Jones GK, Johnson G. A prospective randomized comparison in humans of biphasic waveform 60-μF and 120-μF capacitance pulses using a unipolar defibrillation system. Circulation. 1995;91:91-95.
-
(1995)
Circulation
, vol.91
, pp. 91-95
-
-
Bardy, G.H.1
Poole, J.E.2
Kudenchuk, P.J.3
Dolack, G.L.4
Mehra, R.5
DeGroot, P.6
Raitt, M.H.7
Jones, G.K.8
Johnson, G.9
-
5
-
-
0028110428
-
Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators
-
Swerdlow CD, Kass RM, Chen P-S, Hwang C, Raissi S. Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators. Circulation. 1994;90:1840-1846.
-
(1994)
Circulation
, vol.90
, pp. 1840-1846
-
-
Swerdlow, C.D.1
Kass, R.M.2
Chen, P.-S.3
Hwang, C.4
Raissi, S.5
-
6
-
-
0028219195
-
Hemodynamic deterioration during ICD implant: Predictor of high risk patients
-
Steinbeck G, Dorwarth U, Mauke S, Hoffmann E, Markewitz A, Kaulbach K, Tassani P. Hemodynamic deterioration during ICD implant: predictor of high risk patients. Am Heart J. 1994;127(pt 2):1064-1067.
-
(1994)
Am Heart J.
, vol.127
, Issue.2 PART
, pp. 1064-1067
-
-
Steinbeck, G.1
Dorwarth, U.2
Mauke, S.3
Hoffmann, E.4
Markewitz, A.5
Kaulbach, K.6
Tassani, P.7
-
7
-
-
0031944323
-
Effect of shock waveform on relationship between upper limit of vulnerability and defibrillation
-
Swerdlow CD, Kass RM, O'Connor ME, Chen P-S. Effect of shock waveform on relationship between upper limit of vulnerability and defibrillation. J Cardiovasc Electrophysiol. 1998;9:339-349.
-
(1998)
J Cardiovasc Electrophysiol
, vol.9
, pp. 339-349
-
-
Swerdlow, C.D.1
Kass, R.M.2
O'Connor, M.E.3
Chen, P.-S.4
-
8
-
-
16944364388
-
Programming of implantable cardioverter-defibrillators on the basis of the upper limit of vulnerability
-
Swerdlow CD, Peter CT, Kass RM, Gang ES, Mandel WJ, Hwang C, Martin DJ, Chen P-S. Programming of implantable cardioverter-defibrillators on the basis of the upper limit of vulnerability. Circulation. 1997;95:1497-1504.
-
(1997)
Circulation
, vol.95
, pp. 1497-1504
-
-
Swerdlow, C.D.1
Peter, C.T.2
Kass, R.M.3
Gang, E.S.4
Mandel, W.J.5
Hwang, C.6
Martin, D.J.7
Chen, P.-S.8
-
9
-
-
0028919766
-
Comparison of upper limit of vulnerability and defibrillation probability of success curves using a nonthoracotomy lead system
-
Souza JJ, Malkin RA, Ideker RE. Comparison of upper limit of vulnerability and defibrillation probability of success curves using a nonthoracotomy lead system. Circulation. 1995;91:1247-1252.
-
(1995)
Circulation
, vol.91
, pp. 1247-1252
-
-
Souza, J.J.1
Malkin, R.A.2
Ideker, R.E.3
-
10
-
-
0027212169
-
Relation between upper limit of vulnerability and defibrillation thresholds in humans
-
Chen P-S, Feld GK, Kriett JM, Mower MM, Tarazi RY, Fleck P, Swerdlow CD, Gang ES, Kass RM. Relation between upper limit of vulnerability and defibrillation thresholds in humans. Circulation. 1993; 88:186-192.
-
(1993)
Circulation
, vol.88
, pp. 186-192
-
-
Chen, P.-S.1
Feld, G.K.2
Kriett, J.M.3
Mower, M.M.4
Tarazi, R.Y.5
Fleck, P.6
Swerdlow, C.D.7
Gang, E.S.8
Kass, R.M.9
-
11
-
-
0029051568
-
Effects of the pacing site, procainamide and lead configuration on the relationship between the upper limit of vulnerability and the defibrillation threshold
-
Fan W, Gotoh M, Chen P-S. Effects of the pacing site, procainamide and lead configuration on the relationship between the upper limit of vulnerability and the defibrillation threshold. Pacing Clin Electrophysiol. 1995; 18:1279-1284.
-
(1995)
Pacing Clin Electrophysiol
, vol.18
, pp. 1279-1284
-
-
Fan, W.1
Gotoh, M.2
Chen, P.-S.3
-
12
-
-
0026599239
-
Effects of lidocaine on relation between defibrillation threshold and upper limit of vulnerability in open-chest dogs
-
Topham SL, Cha Y-M, Peters BB, Chen P-S. Effects of lidocaine on relation between defibrillation threshold and upper limit of vulnerability in open-chest dogs. Circulation. 1992;85:1146-1151.
-
(1992)
Circulation
, vol.85
, pp. 1146-1151
-
-
Topham, S.L.1
Cha, Y.-M.2
Peters, B.B.3
Chen, P.-S.4
-
13
-
-
0001421841
-
Ventricular fibrillation due to single, localized induction and condenser shocks applied during the vulnerable phase of ventricular systole
-
Wiggers CJ, Wegria R. Ventricular fibrillation due to single, localized induction and condenser shocks applied during the vulnerable phase of ventricular systole. Am J Physiol. 1940;128:500-505.
-
(1940)
Am J Physiol
, vol.128
, pp. 500-505
-
-
Wiggers, C.J.1
Wegria, R.2
-
14
-
-
0022598194
-
Comparison of defibrillation threshold and the upper limit of ventricular vulnerability
-
Chen P-S, Shibata N, Dixon EG, Martin RO, Ideker RE. Comparison of defibrillation threshold and the upper limit of ventricular vulnerability. Circulation. 1986;73:1022-1028.
-
(1986)
Circulation
, vol.73
, pp. 1022-1028
-
-
Chen, P.-S.1
Shibata, N.2
Dixon, E.G.3
Martin, R.O.4
Ideker, R.E.5
-
15
-
-
0028034988
-
A minimal model of the single capacitor biphasic defibrillation waveform
-
Kroll MW. A minimal model of the single capacitor biphasic defibrillation waveform. Pacing Clin Electrophysiol. 1994;17:1:1782-1792.
-
(1994)
Pacing Clin Electrophysiol
, vol.17
, Issue.1
, pp. 1782-1792
-
-
Kroll, M.W.1
-
16
-
-
0030861679
-
Effects of transvenous electrode polarity and waveform duration on the relationship between defibrillation threshold and upper limit of vulnerability
-
Huang J, KenKnight BH, Walcott GP, Rollins DL, Smith WM, Ideker RE. Effects of transvenous electrode polarity and waveform duration on the relationship between defibrillation threshold and upper limit of vulnerability. Circulation. 1997;96:1351-1359.
-
(1997)
Circulation
, vol.96
, pp. 1351-1359
-
-
Huang, J.1
Kenknight, B.H.2
Walcott, G.P.3
Rollins, D.L.4
Smith, W.M.5
Ideker, R.E.6
-
17
-
-
0028197691
-
Randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode
-
Bardy GH, Dolack GL, Kudenchuk PJ, Poole JE, Mehra R, Johnson G. Randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Circulation. 1994;89:1090-1093.
-
(1994)
Circulation
, vol.89
, pp. 1090-1093
-
-
Bardy, G.H.1
Dolack, G.L.2
Kudenchuk, P.J.3
Poole, J.E.4
Mehra, R.5
Johnson, G.6
-
18
-
-
0032080562
-
Comparison of single- and dual-coil active pectoral defibrillation lead systems
-
Gold MR, Olsovsky MR, Pelini MA, Peters RW, Shorofsky SR. Comparison of single- and dual-coil active pectoral defibrillation lead systems. J Am Coll Cardiol. 1998;31:1391-1394.
-
(1998)
J Am Coll Cardiol
, vol.31
, pp. 1391-1394
-
-
Gold, M.R.1
Olsovsky, M.R.2
Pelini, M.A.3
Peters, R.W.4
Shorofsky, S.R.5
-
19
-
-
0029767428
-
A conceptual basis for defibrillation waveforms
-
Cleland BG. A conceptual basis for defibrillation waveforms. Pacing Clin Electrophysiol. 1996;19:1186-1195.
-
(1996)
Pacing Clin Electrophysiol
, vol.19
, pp. 1186-1195
-
-
Cleland, B.G.1
-
20
-
-
0024591031
-
Ventricular defibrillation using biphasic waveforms: The importance of phasic duration
-
Tang ASL, Yabe S, Wharton JM, Dolker M, Smith WM, Ideker RE. Ventricular defibrillation using biphasic waveforms: the importance of phasic duration. J Am Coll Cardiol. 1989;13:207-214.
-
(1989)
J Am Coll Cardiol
, vol.13
, pp. 207-214
-
-
Tang, A.S.L.1
Yabe, S.2
Wharton, J.M.3
Dolker, M.4
Smith, W.M.5
Ideker, R.E.6
-
21
-
-
0029760653
-
Large change in voltage at phase reversal improve biphasic defibrillation thresholds
-
Yamanouchi Y, Mowrey KA, Nadzam GR, Hills DG, Kroll MW, Brewer JE, Donohoo AM, Wilkoff BL, Tchou PJ. Large change in voltage at phase reversal improve biphasic defibrillation thresholds. Circulation. 1996;94:1768-1773.
-
(1996)
Circulation
, vol.94
, pp. 1768-1773
-
-
Yamanouchi, Y.1
Mowrey, K.A.2
Nadzam, G.R.3
Hills, D.G.4
Kroll, M.W.5
Brewer, J.E.6
Donohoo, A.M.7
Wilkoff, B.L.8
Tchou, P.J.9
-
22
-
-
0029130660
-
Effect of rapid pacing and t-wave scanning on the relation between the defibrillation and upper-limit-of-vulnerability dose-response curves
-
Malkin RA, Idriss SF, Walker RG, Ideker RE. Effect of rapid pacing and T-wave scanning on the relation between the defibrillation and upper-limit-of-vulnerability dose-response curves. Circulation. 1995;92: 1291-1299.
-
(1995)
Circulation
, vol.92
, pp. 1291-1299
-
-
Malkin, R.A.1
Idriss, S.F.2
Walker, R.G.3
Ideker, R.E.4
-
23
-
-
0031034415
-
The zone of vulnerability to T-wave shocks in humans
-
Swerdlow CD, Martin DJ, Kass RM, Davie S, Mandel WJ, Gang ES, Chen P-S. The zone of vulnerability to T-wave shocks in humans. J Cardiovasc Electrophysiol. 1997;8:145-154.
-
(1997)
J Cardiovasc Electrophysiol
, vol.8
, pp. 145-154
-
-
Swerdlow, C.D.1
Martin, D.J.2
Kass, R.M.3
Davie, S.4
Mandel, W.J.5
Gang, E.S.6
Chen, P.-S.7
|