메뉴 건너뛰기




Volumn 24, Issue 14, 1999, Pages 1477-1482

Peroperative determination of safe superior transarticular screw trajectory through the lateral mass

Author keywords

Anatomy; Axis; Computer aided design; Transarticular screw; Vertebral artery

Indexed keywords

ARTERY INJURY; ARTICLE; AXIS; BONE SCREW; CERVICAL SPINE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FLUOROSCOPY; HUMAN; HUMAN TISSUE; INTRAOPERATIVE PERIOD; OSTEOMETRY; PRIORITY JOURNAL; SAFETY; SURGICAL ANATOMY; VERTEBRAL ARTERY;

EID: 0033565846     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-199907150-00014     Document Type: Article
Times cited : (47)

References (24)
  • 2
    • 0028867884 scopus 로고
    • Generation of new-lead structures in computer-aided drug design
    • Cohen NC, Tschinke V. Generation of new-lead structures in computer-aided drug design. Prog Drug Res 1995;45:205-43.
    • (1995) Prog Drug Res , vol.45 , pp. 205-243
    • Cohen, N.C.1    Tschinke, V.2
  • 3
    • 0018852348 scopus 로고
    • Bone erosion of the cervical vertebrae secondary to tortuousity of the vertebral artery
    • Cooper DF. Bone erosion of the cervical vertebrae secondary to tortuousity of the vertebral artery. J Neurosurg 1980;53:106-8.
    • (1980) J Neurosurg , vol.53 , pp. 106-108
    • Cooper, D.F.1
  • 4
    • 0029066955 scopus 로고
    • Preoperative oblique axial computed tomographic imaging for C1-C2 transarticular screw fixation: Technical note
    • Dull ST, Toselli RM. Preoperative oblique axial computed tomographic imaging for C1-C2 transarticular screw fixation: Technical note. Neurosurgery 1995;37:149-52.
    • (1995) Neurosurgery , vol.37 , pp. 149-152
    • Dull, S.T.1    Toselli, R.M.2
  • 5
    • 0343792986 scopus 로고
    • Anatomical assessment of atlanto-axial transarticular screw fixation
    • New York, NY, December 1-4
    • Gebhard JS, Jeanneret B. anatomical assessment of atlanto-axial transarticular screw fixation. Presented at the Cervical Spine Research Society Meeting, New York, NY, December 1-4, 1993.
    • (1993) Cervical Spine Research Society Meeting
    • Gebhard, J.S.1    Jeanneret, B.2
  • 7
    • 0028866563 scopus 로고
    • Update on computer-aided drug design
    • Jackson-RC: Update on computer-aided drug design. Curr Opin Biotechnol 1995;6:646-51.
    • (1995) Curr Opin Biotechnol , vol.6 , pp. 646-651
  • 8
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi AA, Casey ATH, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997;86:961-8.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.H.2    Solanki, G.A.3    Tuite, G.4    Veres, R.5    Crockard, H.A.6
  • 10
    • 0002257576 scopus 로고
    • Stable posterior fusion of the atlas and axis by transarticular screw fixation
    • Kehr P, Weidner A, eds. Wien: Springer-Verlag
    • Magerl F, Seemann P: Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A, eds. Cervical Spine I. Wien: Springer-Verlag, 1987:322-7.
    • (1987) Cervical Spine I , pp. 322-327
    • Magerl, F.1    Seemann, P.2
  • 11
  • 13
    • 0027944270 scopus 로고
    • Occipitocecvical fusion with posterior plate and screw instrumentation: A long term follow up study
    • Sasso RC, Jeanneret B, Fischer K, Magerl F. Occipitocecvical fusion with posterior plate and screw instrumentation: A long term follow up study. Spine 1994;19:2364-8.
    • (1994) Spine , vol.19 , pp. 2364-2368
    • Sasso, R.C.1    Jeanneret, B.2    Fischer, K.3    Magerl, F.4
  • 14
  • 15
    • 0029881668 scopus 로고    scopus 로고
    • Use of electronic callipers for radiological and clinical measurements
    • Solanki G, Tammam A, Crockard HA, Stevens J. Use of electronic callipers for radiological and clinical measurements. Lancet 1996;347:828-9.
    • (1996) Lancet , vol.347 , pp. 828-829
    • Solanki, G.1    Tammam, A.2    Crockard, H.A.3    Stevens, J.4
  • 16
    • 0030064377 scopus 로고    scopus 로고
    • 3D computer data capture and imaging applied to the face and jaws
    • Spencer R, Hathaway R, Speculand B. 3D computer data capture and imaging applied to the face and jaws. Br J Oral Maxillofac Surg 1996;34:118-23.
    • (1996) Br J Oral Maxillofac Surg , vol.34 , pp. 118-123
    • Spencer, R.1    Hathaway, R.2    Speculand, B.3
  • 17
    • 0029937772 scopus 로고    scopus 로고
    • Computer-aided design optimization with the use of a fast dose model for linear-accelerator-based stereotactic radiosurgery
    • Suh TS, Bova FJ, Yoon SC, et al. Computer-aided design optimization with the use of a fast dose model for linear-accelerator-based stereotactic radiosurgery. Phys Med Biol 1996;41:675-96.
    • (1996) Phys Med Biol , vol.41 , pp. 675-696
    • Suh, T.S.1    Bova, F.J.2    Yoon, S.C.3
  • 19
    • 0024553625 scopus 로고
    • Erosion of the foramina transversarium of the axis
    • Taitz C, Arensburg B. Erosion of the foramina transversarium of the axis. Acta Anat 1989;134:12-14.
    • (1989) Acta Anat , vol.134 , pp. 12-14
    • Taitz, C.1    Arensburg, B.2
  • 20
    • 84940621279 scopus 로고
    • Vertebral artery tortuosity with concomitant erosion of the foramen of the transverse process of the axis. Possible clinical implications
    • Taitz C, Arensburg B. Vertebral artery tortuosity with concomitant erosion of the foramen of the transverse process of the axis. Possible clinical implications. Acta Anat 1991;141:104-8.
    • (1991) Acta Anat , vol.141 , pp. 104-108
    • Taitz, C.1    Arensburg, B.2
  • 22
  • 23
    • 0018838842 scopus 로고
    • Anomalous foramen transversarium of C2 simulating erosion of bone
    • Wickbom GI, Williamson MR. Anomalous foramen transversarium of C2 simulating erosion of bone. Neuroradiology 1980;19:43-5.
    • (1980) Neuroradiology , vol.19 , pp. 43-45
    • Wickbom, G.I.1    Williamson, M.R.2
  • 24
    • 0031896021 scopus 로고    scopus 로고
    • Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves
    • Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. J Neurosurg 1998;88:634-40.
    • (1998) J Neurosurg , vol.88 , pp. 634-640
    • Wright, N.M.1    Lauryssen, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.