메뉴 건너뛰기




Volumn 14, Issue 3, 1999, Pages 283-287

Application of enzyme field-effect transistors for determination of glucose concentrations in blood serum

Author keywords

Blood serum; ENFET; Glucose; Nation

Indexed keywords

BLOOD; ENZYMES; FIELD EFFECT TRANSISTORS; FLUORINE CONTAINING POLYMERS; POLYMERIC MEMBRANES;

EID: 0033558888     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(99)00007-X     Document Type: Article
Times cited : (73)

References (12)
  • 1
    • 0014698380 scopus 로고
    • Development of an ion-sensitive solid-state device for neurophysiological measurements
    • Bergveld P. Development of an ion-sensitive solid-state device for neurophysiological measurements. IEEE Trans. Biomed. Eng. BME. 17:1970;70-71.
    • (1970) IEEE Trans. Biomed. Eng. BME , vol.17 , pp. 70-71
    • Bergveld, P.1
  • 2
    • 0019176570 scopus 로고
    • Field effect transistor sensitive to penicillin
    • Caras S., Janata J. Field effect transistor sensitive to penicillin. Anal. Chem. 52:1980;1935-1937.
    • (1980) Anal. Chem. , vol.52 , pp. 1935-1937
    • Caras, S.1    Janata, J.2
  • 4
    • 0024095481 scopus 로고
    • Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
    • Harrison D.J., Turner R.F.B., Baltes H.P. Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood. Anal. Chem. 60:1988;2002-2007.
    • (1988) Anal. Chem. , vol.60 , pp. 2002-2007
    • Harrison, D.J.1    Turner, R.F.B.2    Baltes, H.P.3
  • 5
    • 0027574969 scopus 로고
    • Biosensors - What real progress is being made?
    • Griffiths D., Hall G. Biosensors - what real progress is being made? Tibtech. 11:1993;122-130.
    • (1993) Tibtech , vol.11 , pp. 122-130
    • Griffiths, D.1    Hall, G.2
  • 6
    • 0344262871 scopus 로고
    • L'viv Plant of Bacterial preparation, Ukraine, Product Information
    • L'viv Plant of Bacterial preparation, Ukraine, 1994. Enzymatic kit 'Diagluc'. Product Information.
    • (1994) Enzymatic Kit 'Diagluc'
  • 7
    • 0344262870 scopus 로고
    • Panevezhis Plant of precision mechanics, Lithuania, Product Information and Manual Operation
    • Panevezhis Plant of precision mechanics, Lithuania, 1990. Eksan-G, Product Information and Manual Operation.
    • (1990) Eksan-G
  • 9
    • 0027420908 scopus 로고
    • Glucose-sensitive field effect transistor with additional Nafion membrane. Reduction of influence of buffer capacity on the sensor response and extension of its dynamic range
    • Soldatkin A.P., El'skaya A.V., Shul'ga A.A., Netchiporouk L.I., Nyamsi Hendji A.M., Jaffrezic-Renault N, Martelet C. Glucose-sensitive field effect transistor with additional Nafion membrane. Reduction of influence of buffer capacity on the sensor response and extension of its dynamic range. Anal. Chim. Acta. 283:1993;695-701.
    • (1993) Anal. Chim. Acta , vol.283 , pp. 695-701
    • Soldatkin, A.P.1    El'skaya, A.V.2    Shul'ga, A.A.3    Netchiporouk, L.I.4    Nyamsi Hendji, A.M.5    Jaffrezic-Renault, N.6    Martelet, C.7
  • 10
    • 0028214485 scopus 로고
    • Glucose sensitive conductometric biosensor with additional Nafion membrane: Reduction of influence of buffer capacity on the sensor response and extension of its dynamic range
    • Soldatkin A.P., El'skaya A.V., Shul'ga A.A., Jdanova A.S., Dzyedevich S.V., Jaffrezic-Renault N, Martelet C., Clechet P. Glucose sensitive conductometric biosensor with additional Nafion membrane: reduction of influence of buffer capacity on the sensor response and extension of its dynamic range. Anal. Chim. Acta. 288:1994;197-203.
    • (1994) Anal. Chim. Acta , vol.288 , pp. 197-203
    • Soldatkin, A.P.1    El'skaya, A.V.2    Shul'ga, A.A.3    Jdanova, A.S.4    Dzyedevich, S.V.5    Jaffrezic-Renault, N.6    Martelet, C.7    Clechet, P.8
  • 11
    • 0030007955 scopus 로고    scopus 로고
    • Glucose-sensitive ion-sensitive field-effect transistor-based biosensor with additional positively charged membrane. Dynamic range extension and reduction of buffer concentration influence on the sensor response
    • Volotovsky V.V., Soldatkin A.P., Shul'ga A.A., Rossokhaty V.K., Strikha V.I., El'skaya A.V. Glucose-sensitive ion-sensitive field-effect transistor-based biosensor with additional positively charged membrane. Dynamic range extension and reduction of buffer concentration influence on the sensor response. Anal. Chim. Acta. 322:1996;77-81.
    • (1996) Anal. Chim. Acta , vol.322 , pp. 77-81
    • Volotovsky, V.V.1    Soldatkin, A.P.2    Shul'ga, A.A.3    Rossokhaty, V.K.4    Strikha, V.I.5    El'skaya, A.V.6
  • 12
    • 0006731263 scopus 로고    scopus 로고
    • Device for measuring of gate potential of ion-sensitive field effect transistor
    • Volotovsky V.V., Patskovsky S.V. Device for measuring of gate potential of ion-sensitive field effect transistor. Devices Exp. Tech. 3:1996;168.
    • (1996) Devices Exp. Tech. , vol.3 , pp. 168
    • Volotovsky, V.V.1    Patskovsky, S.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.