1
-
-
0025179228
-
Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
-
Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 1990;16:637-643.
-
(1990)
J Am Coll Cardiol
, vol.16
, pp. 637-643
-
-
Dumesnil, J.G.1
Honos, G.N.2
Lemieux, M.3
Beauchemin, J.4
-
2
-
-
0029996394
-
The effect of prosthesis-patient mismatch on aortic bioprosthetic valve hemodynamic performance and patient clinical status
-
Pibarot P, Honos GN, Durand L-G, Dumesnil JG. The effect of prosthesis-patient mismatch on aortic bioprosthetic valve hemodynamic performance and patient clinical status. Can J Cardiol 1996;12:379-387.
-
(1996)
Can J Cardiol
, vol.12
, pp. 379-387
-
-
Pibarot, P.1
Honos, G.N.2
Durand, L.-G.3
Dumesnil, J.G.4
-
3
-
-
0031971981
-
Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity, and mortality after aortic valve replacement with a bioprosthetic heart valve
-
Pibarot P, Dumesnil JG, Lemieux M, Cartier P, Métras J, Durand, LG. Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity, and mortality after aortic valve replacement with a bioprosthetic heart valve. J Heart Valve Dis 1998;7:211-218.
-
(1998)
J Heart Valve Dis
, vol.7
, pp. 211-218
-
-
Pibarot, P.1
Dumesnil, J.G.2
Lemieux, M.3
Cartier, P.4
Métras, J.5
Durand, L.G.6
-
4
-
-
0026438436
-
Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients
-
Dumesnil JG, Yoganathan AP. Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients. Eur J Cardio-thorac Surg 1992;6(suppl I):I-34-I-38.
-
(1992)
Eur J Cardio-thorac Surg
, vol.6
, Issue.SUPPL. I
-
-
Dumesnil, J.G.1
Yoganathan, A.P.2
-
5
-
-
10244252722
-
Predictive value of prosthetic valve area index for early and late clinical results after valve replacement with the St. Jude Medical valve prosthesis
-
Fernandez J, Chen C, Laub GW, Anderson WA, Brdlik OB, Murphy MM, McGrath LB. Predictive value of prosthetic valve area index for early and late clinical results after valve replacement with the St. Jude Medical valve prosthesis. Circulation 1996;94(suppl II):II-109-II-112.
-
(1996)
Circulation
, vol.94
, Issue.SUPPL. II
-
-
Fernandez, J.1
Chen, C.2
Laub, G.W.3
Anderson, W.A.4
Brdlik, O.B.5
Murphy, M.M.6
McGrath, L.B.7
-
7
-
-
0027155957
-
Ventilatory anaerobic threshold before and after cardiac valve surgery
-
Nishijima H, Sato I, Matsumura N, Mikami T, Nishida M, Yonezawa K, Yasuda H. Ventilatory anaerobic threshold before and after cardiac valve surgery. Jpn Circ J 1993;57:208-214.
-
(1993)
Jpn Circ J
, vol.57
, pp. 208-214
-
-
Nishijima, H.1
Sato, I.2
Matsumura, N.3
Mikami, T.4
Nishida, M.5
Yonezawa, K.6
Yasuda, H.7
-
9
-
-
0029337145
-
Substitution of left ventricular outflow tract diameter with prosthesis size is inadequate for calculation of the aortic prosthetic valve area by the continuity equation
-
Pibarot P, Honos GN, Durand LG, Dumesnil JG. Substitution of left ventricular outflow tract diameter with prosthesis size is inadequate for calculation of the aortic prosthetic valve area by the continuity equation. J Am Soc Echocardiogr 1995;8:511-517.
-
(1995)
J Am Soc Echocardiogr
, vol.8
, pp. 511-517
-
-
Pibarot, P.1
Honos, G.N.2
Durand, L.G.3
Dumesnil, J.G.4
-
10
-
-
0023872276
-
Differing mechanisms of exercise flow augmentation at the mitral and aortic valves
-
Rassi A, Crawford MH, Richards KL, Miller JF. Differing mechanisms of exercise flow augmentation at the mitral and aortic valves. Circulation 1988;77:543-551.
-
(1988)
Circulation
, vol.77
, pp. 543-551
-
-
Rassi, A.1
Crawford, M.H.2
Richards, K.L.3
Miller, J.F.4
-
11
-
-
0024436151
-
Rest and exercise evaluation of St. Jude Medical and Medtronic Hall prostheses
-
Tatineni S, Barner HB, Pearson AC, Halbe D, Woodruff R, Labovitz AJ. Rest and exercise evaluation of St. Jude Medical and Medtronic Hall prostheses. Circulation 1989;80(suppl I):I-16-I-23.
-
(1989)
Circulation
, vol.80
, Issue.SUPPL. I
-
-
Tatineni, S.1
Barner, H.B.2
Pearson, A.C.3
Halbe, D.4
Woodruff, R.5
Labovitz, A.J.6
-
12
-
-
0030904511
-
Effects of aortic valve replacement on exercise duration and functional status in adults with valvular aortic stenosis
-
Munt BI, Legget ME, Healy NL, Fujioka M, Schwaegler R, Otto CM. Effects of aortic valve replacement on exercise duration and functional status in adults with valvular aortic stenosis. Can J Cardiol 1997;13:346-350.
-
(1997)
Can J Cardiol
, vol.13
, pp. 346-350
-
-
Munt, B.I.1
Legget, M.E.2
Healy, N.L.3
Fujioka, M.4
Schwaegler, R.5
Otto, C.M.6
-
13
-
-
0024995193
-
Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St. Jude Medical valves in the aortic position
-
Jaffe WM, Coverdale HAG, Roche AH, Whitlock RML, Neutze JM, Barratt-Boyes BG. Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St. Jude Medical valves in the aortic position. J Thorac Cardiovasc Surg 1990;100:167-174.
-
(1990)
J Thorac Cardiovasc Surg
, vol.100
, pp. 167-174
-
-
Jaffe, W.M.1
Coverdale, H.A.G.2
Roche, A.H.3
Whitlock, R.M.L.4
Neutze, J.M.5
Barratt-Boyes, B.G.6
-
14
-
-
0026533821
-
Value of exercise Doppler echo cardiograph y in patients with prosthetic or bioprosthetic cardiac valves
-
Van Den Brink RB, Verheul HA, Visser CA, Koelemay MJW, Dunning AJ. Value of exercise Doppler echo cardiograph y in patients with prosthetic or bioprosthetic cardiac valves. Am J Cardiol 1992;69:367-372.
-
(1992)
Am J Cardiol
, vol.69
, pp. 367-372
-
-
Van Den Brink, R.B.1
Verheul, H.A.2
Visser, C.A.3
Koelemay, M.J.W.4
Dunning, A.J.5
-
15
-
-
0027389147
-
Exercise hemodynamics in small (≤21 mm) aortic valve prostheses assessed by Doppler echocardiography
-
Wiseth R, Levang OW, Tangen G, Rein KA, Skjaerpe T, Hatle L. Exercise hemodynamics in small (≤21 mm) aortic valve prostheses assessed by Doppler echocardiography. Am Heart J 1993;125:138-146.
-
(1993)
Am Heart J
, vol.125
, pp. 138-146
-
-
Wiseth, R.1
Levang, O.W.2
Tangen, G.3
Rein, K.A.4
Skjaerpe, T.5
Hatle, L.6
-
16
-
-
0028358858
-
Doppler echocardiography evaluation of the Carbomedics valve in patients with small aortic annulus and valve prosthesis-body surface area mismatch
-
DePaulis R, Sommariva L, Russo F, Tomai F, Tondo A, Pagliaricci C, Bassano C, Chiariello L. Doppler echocardiography evaluation of the Carbomedics valve in patients with small aortic annulus and valve prosthesis-body surface area mismatch. J Thorac Cardiovasc Surg 1994;108:57-62.
-
(1994)
J Thorac Cardiovasc Surg
, vol.108
, pp. 57-62
-
-
DePaulis, R.1
Sommariva, L.2
Russo, F.3
Tomai, F.4
Tondo, A.5
Pagliaricci, C.6
Bassano, C.7
Chiariello, L.8
-
17
-
-
0026112890
-
Validation of the orifice formula for estimating effective heart valve opening area
-
Cochrane T, Kenyon CJ, Lawford PV, Black MM, Chambers JB, Sprigings DC. Validation of the orifice formula for estimating effective heart valve opening area. Clin Phys Physiol Meas 1991;12:21-37.
-
(1991)
Clin Phys Physiol Meas
, vol.12
, pp. 21-37
-
-
Cochrane, T.1
Kenyon, C.J.2
Lawford, P.V.3
Black, M.M.4
Chambers, J.B.5
Sprigings, D.C.6
-
18
-
-
0026734686
-
Doppler assessment of prosthetic valve orifice area. An in vitro study
-
Baumgartner H, Khan SS, DeRobertis M, Czer LS, Maurer G. Doppler assessment of prosthetic valve orifice area. An in vitro study. Circulation 1992;85:2275-2283.
-
(1992)
Circulation
, vol.85
, pp. 2275-2283
-
-
Baumgartner, H.1
Khan, S.S.2
Derobertis, M.3
Czer, L.S.4
Maurer, G.5
-
19
-
-
0024439255
-
Effect of systolic flow rate on the prediction of effective prosthetic valve orifice area
-
Schoephoerster R, Chandran KB. Effect of systolic flow rate on the prediction of effective prosthetic valve orifice area. J Biomech 1989;22:705-715.
-
(1989)
J Biomech
, vol.22
, pp. 705-715
-
-
Schoephoerster, R.1
Chandran, K.B.2
-
20
-
-
0030981056
-
Use a dobutamine stress echocardiography in assessing mechanical aortic prostheses: Comparison with exercise echocardiography
-
Zabalgoitia M, Kopec K, Oneschuk L, Linn W, Herrera CJ, O'Rourke RA. Use a dobutamine stress echocardiography in assessing mechanical aortic prostheses: comparison with exercise echocardiography. J Heart Valve Dis 1997;6:253-257.
-
(1997)
J Heart Valve Dis
, vol.6
, pp. 253-257
-
-
Zabalgoitia, M.1
Kopec, K.2
Oneschuk, L.3
Linn, W.4
Herrera, C.J.5
O'Rourke, R.A.6
|