메뉴 건너뛰기




Volumn 222, Issue 1-4, 1999, Pages 123-128

An analytical solution for the capture zone of two arbitrarily located wells

Author keywords

Analytical solution; Capture zone; Groundwater containment and remediation

Indexed keywords

CAPTURE ZONE; GROUNDWATER CONTAINMENT AND REMEDIATION;

EID: 0033552090     PISSN: 00221694     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-1694(99)00101-8     Document Type: Article
Times cited : (60)

References (17)
  • 1
    • 0025572890 scopus 로고
    • Well location in capture zone design using simulation and optimization techniques
    • Ahlfeld D.P., Sawyer C.S. Well location in capture zone design using simulation and optimization techniques. Ground Water. 28:(4):1990;507-512.
    • (1990) Ground Water , vol.28 , Issue.4 , pp. 507-512
    • Ahlfeld, D.P.1    Sawyer, C.S.2
  • 2
    • 0026837261 scopus 로고
    • Comparison of flow models used to delineate capture zones of wells: 1. Leaky-confined fractured carbonate aquifer
    • Bair E.S., Roadcap G.S. Comparison of flow models used to delineate capture zones of wells: 1. Leaky-confined fractured carbonate aquifer. Ground Water. 30:(2):1992;199-211.
    • (1992) Ground Water , vol.30 , Issue.2 , pp. 199-211
    • Bair, E.S.1    Roadcap, G.S.2
  • 4
    • 0029413024 scopus 로고
    • Hydrodynamics of the capture zone of a partially penetrating well in a confined aquifer
    • Faybishenko B.A., Javandel I., Witherspoon P.A. Hydrodynamics of the capture zone of a partially penetrating well in a confined aquifer. Water Resour. Res. 31:(4):1995;859-866.
    • (1995) Water Resour. Res. , vol.31 , Issue.4 , pp. 859-866
    • Faybishenko, B.A.1    Javandel, I.2    Witherspoon, P.A.3
  • 5
    • 84987564400 scopus 로고
    • Design of optimal, reliable plume capture schemes: Application to the Gloucester Landfill ground-water contamination
    • Gailey R.M., Gorelick S.M. Design of optimal, reliable plume capture schemes: application to the Gloucester Landfill ground-water contamination. Ground Water. 31:(1):1993;107-114.
    • (1993) Ground Water , vol.31 , Issue.1 , pp. 107-114
    • Gailey, R.M.1    Gorelick, S.M.2
  • 7
    • 84987515842 scopus 로고
    • Analytical model for estimation of steady-state capture zones of pumping wells in confined and unconfined aquifers
    • Grubb S. Analytical model for estimation of steady-state capture zones of pumping wells in confined and unconfined aquifers. Ground Water. 31:(1):1993;27-32.
    • (1993) Ground Water , vol.31 , Issue.1 , pp. 27-32
    • Grubb, S.1
  • 8
    • 84987505885 scopus 로고
    • Ground-water remediation using "smart pump and treat"
    • Hoffman F. Ground-water remediation using "smart pump and treat" Ground Water. 31:(1):1993;98-106.
    • (1993) Ground Water , vol.31 , Issue.1 , pp. 98-106
    • Hoffman, F.1
  • 9
    • 0022923257 scopus 로고
    • Capture-zone type curves: A tool for aquifer clean up
    • Javandel I., Tsang C.-F. Capture-zone type curves: a tool for aquifer clean up. Ground Water. 24:(5):1986;616-625.
    • (1986) Ground Water , vol.24 , Issue.5 , pp. 616-625
    • Javandel, I.1    Tsang, C.-F.2
  • 11
    • 0027036884 scopus 로고
    • Well catchments and time of travel zones in aquifers with recharge
    • Lerner D.N. Well catchments and time of travel zones in aquifers with recharge. Water Resour. Res. 28:(10):1992;2621-2628.
    • (1992) Water Resour. Res. , vol.28 , Issue.10 , pp. 2621-2628
    • Lerner, D.N.1
  • 12
    • 0026897745 scopus 로고
    • Optimal design of ground-water capture systems using segmental velocity-direction constraints
    • Ratzlaff S.A., Aral M.M., Al-Khayyal F. Optimal design of ground-water capture systems using segmental velocity-direction constraints. Ground Water. 30:(4):1992;607-612.
    • (1992) Ground Water , vol.30 , Issue.4 , pp. 607-612
    • Ratzlaff, S.A.1    Aral, M.M.2    Al-Khayyal, F.3
  • 13
    • 0030189540 scopus 로고    scopus 로고
    • Determining 3D capture zone in homogeneous, anisotropic aquifers
    • Schafer D.C. Determining 3D capture zone in homogeneous, anisotropic aquifers. Ground Water. 34:(4):1996;628-639.
    • (1996) Ground Water , vol.34 , Issue.4 , pp. 628-639
    • Schafer, D.C.1
  • 14
    • 0023524192 scopus 로고
    • Reverse path line calculation of time-related capture zone in nonuniform flow
    • Shafer J.M. Reverse path line calculation of time-related capture zone in nonuniform flow. Ground Water. 25:(3):1987;283-289.
    • (1987) Ground Water , vol.25 , Issue.3 , pp. 283-289
    • Shafer, J.M.1
  • 15
    • 0026954015 scopus 로고
    • Comparison of methods used to delineate capture zones of wells: 2. Stratified-drift buried-valley aquifer
    • Springer A.E., Bair E.S. Comparison of methods used to delineate capture zones of wells: 2. Stratified-drift buried-valley aquifer. Ground Water. 30:(6):1992;908-917.
    • (1992) Ground Water , vol.30 , Issue.6 , pp. 908-917
    • Springer, A.E.1    Bair, E.S.2
  • 16
    • 0027789840 scopus 로고
    • Analysis of uncertainty in optimal groundwater contaminat capture design
    • Tiedeman C., Goreick S.M. Analysis of uncertainty in optimal groundwater contaminat capture design. Water Resour. Res. 29:(7):1993;2139-2153.
    • (1993) Water Resour. Res. , vol.29 , Issue.7 , pp. 2139-2153
    • Tiedeman, C.1    Goreick, S.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.