메뉴 건너뛰기




Volumn 93, Issue 3, 1999, Pages 185-194

Leaf temperature error from heat conduction along thermocouple wires

Author keywords

Conduction error; Leaf temperature; Thermocouple contact; Thermocouple error

Indexed keywords


EID: 0033548644     PISSN: 01681923     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-1923(98)00123-3     Document Type: Article
Times cited : (31)

References (11)
  • 1
    • 0242281308 scopus 로고
    • Leaf temperature measurement and control in a gas-exchange cuvette
    • Beadle C.L., Stevenson K.R., Thurtell G.W. Leaf temperature measurement and control in a gas-exchange cuvette. Can. J. Plant Sci. 53:1973;407-412.
    • (1973) Can. J. Plant Sci. , vol.53 , pp. 407-412
    • Beadle, C.L.1    Stevenson, K.R.2    Thurtell, G.W.3
  • 2
    • 0031881597 scopus 로고    scopus 로고
    • Modelling local-scale frost variations using mobile temperature measurements with a GIS
    • Blennow K., Persson P. Modelling local-scale frost variations using mobile temperature measurements with a GIS. Agric. For. Meteor. 89:1998;59-71.
    • (1998) Agric. For. Meteor. , vol.89 , pp. 59-71
    • Blennow, K.1    Persson, P.2
  • 3
    • 0029682437 scopus 로고    scopus 로고
    • Quantifying energy and mass transfer in crop canopies: Sensors for measurement of temperature and air velocity
    • Bugbee, B., Monje, O., Tanner, B., 1996. Quantifying energy and mass transfer in crop canopies: sensors for measurement of temperature and air velocity, Adv. Space Res. 18(4/5), 149-156.
    • (1996) Adv. Space Res. , vol.18 , Issue.4-5 , pp. 149-156
    • Bugbee, B.1    Monje, O.2    Tanner, B.3
  • 5
    • 0344744741 scopus 로고
    • Leaf temperature measurement in tobacco curing research
    • Hassler F.J. Leaf temperature measurement in tobacco curing research. Tobacco Sci. 1:1957;64-67.
    • (1957) Tobacco Sci. , vol.1 , pp. 64-67
    • Hassler, F.J.1
  • 8
    • 0242376039 scopus 로고
    • Leaf temperature measurement. I. Thermocouples
    • Pieters G.A., Schurer K. Leaf temperature measurement. I. Thermocouples. Acta Bot. Neerl. 22(5):1973;569-580.
    • (1973) Acta Bot. Neerl. , vol.22 , Issue.5 , pp. 569-580
    • Pieters, G.A.1    Schurer, K.2
  • 9
    • 0041671795 scopus 로고
    • Temperature: Critique I
    • In: Tibbitts, T.W., Kozlowski, T.T., (Eds.), Academic Press
    • Tanner, C.B., 1979. Temperature: Critique I., In: Tibbitts, T.W., Kozlowski, T.T., (Eds.), Controlled Environment Guidelines for Plant Research, Academic Press, pp. 117-130.
    • (1979) Controlled Environment Guidelines for Plant Research , pp. 117-130
    • Tanner, C.B.1
  • 10
    • 0000538981 scopus 로고
    • Errors in calculation of evaporation and leaf conductance in steady-state porometry: The importance of accurate measurement of leaf temperature
    • Tyree M.T., Wilmot T.R. Errors in calculation of evaporation and leaf conductance in steady-state porometry: The importance of accurate measurement of leaf temperature. Can. J. For. Res. 20:1990;1031-1035.
    • (1990) Can. J. For. Res. , vol.20 , pp. 1031-1035
    • Tyree, M.T.1    Wilmot, T.R.2
  • 11
    • 23544450320 scopus 로고
    • The calibration of thermocouples for leaf temperature measurements in gas exchange cuvettes
    • Ziegler-Jöns A., Knoppik D., Selinger H. The calibration of thermocouples for leaf temperature measurements in gas exchange cuvettes. Oecologia (Berlin). 68:1986;611-614.
    • (1986) Oecologia (Berlin) , vol.68 , pp. 611-614
    • Ziegler-Jöns, A.1    Knoppik, D.2    Selinger, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.