-
2
-
-
0027454560
-
Dual chamber, rate adaptive pacing in patients with paroxysmal supraventricular tachyarrhythmias: Protective measures for rate control
-
Mond H.G., Barold S.S. Dual chamber, rate adaptive pacing in patients with paroxysmal supraventricular tachyarrhythmias protective measures for rate control . PACE Pacing Clin Electrophysiol. 16:1993;2168-2185.
-
(1993)
PACE Pacing Clin Electrophysiol
, vol.16
, pp. 2168-2185
-
-
Mond, H.G.1
Barold, S.S.2
-
3
-
-
0026703177
-
Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers
-
Lau C.P., Tai Y.U., Fong P.C. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers. PACE Pacing Clin Electrophysiol. 15:1992;1504-1514.
-
(1992)
PACE Pacing Clin Electrophysiol
, vol.15
, pp. 1504-1514
-
-
Lau, C.P.1
Tai, Y.U.2
Fong, P.C.3
-
5
-
-
0028019301
-
Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tachyarrhythmias
-
den Dulk K., Dijkman B., Pieterse M. Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tachyarrhythmias. PACE Pacing Clin Electrophysiol. 17:1994;1900-1907.
-
(1994)
PACE Pacing Clin Electrophysiol
, vol.17
, pp. 1900-1907
-
-
Den Dulk, K.1
Dijkman, B.2
Pieterse, M.3
-
6
-
-
0028109709
-
A new automode switch algorithm for supraventricular tachycardias
-
Levine P.A., Bornzin G.A., Barlow J., Florio J., Sholder J., Tyler J., Mann B. A new automode switch algorithm for supraventricular tachycardias. PACE Pacing Clin Electrophysiol. 17:1994;1895-1899.
-
(1994)
PACE Pacing Clin Electrophysiol
, vol.17
, pp. 1895-1899
-
-
Levine, P.A.1
Bornzin, G.A.2
Barlow, J.3
Florio, J.4
Sholder, J.5
Tyler, J.6
Mann, B.7
-
7
-
-
0028114538
-
Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode
-
Ovsyshcher I.E., Katz A., Bondy C. Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode. PACE Pacing Clin Electrophysiol. 17:1994;1908-1912.
-
(1994)
PACE Pacing Clin Electrophysiol
, vol.17
, pp. 1908-1912
-
-
Ovsyshcher, I.E.1
Katz, A.2
Bondy, C.3
-
8
-
-
0008555715
-
Mode switching in DDDR pacing
-
A.E. Aubert, H. Ector, & R. Stroobandt. Dordrecht, The Netherlands: Kluwer Academic Publishers
-
Sutton R. Mode switching in DDDR pacing. Aubert A.E., Ector H., Stroobandt R. Cardiac Pacing and Electrophysiology A Bridge to the 21st Century . 1994;363-370 Kluwer Academic Publishers, Dordrecht, The Netherlands.
-
(1994)
Cardiac Pacing and Electrophysiology: A Bridge to the 21st Century
, pp. 363-370
-
-
Sutton, R.1
-
9
-
-
0002902915
-
Algorithms for management of atrial fibrillation in patients with dual chamber pacing systems
-
M. Rosenqvist. London: WB Saunders
-
Kay G.N., Bubien R.S. Algorithms for management of atrial fibrillation in patients with dual chamber pacing systems. Rosenqvist M. Cardiac Pacing New Advances . 1997;61-82 WB Saunders, London.
-
(1997)
Cardiac Pacing: New Advances
, pp. 61-82
-
-
Kay, G.N.1
Bubien, R.S.2
-
10
-
-
0027284846
-
Undesirable mode switching with a dual-chamber rate-responsive pacemaker
-
Pitney M.R., May C.D., Davis M.J. Undesirable mode switching with a dual-chamber rate-responsive pacemaker. PACE Pacing Clin Electrophysiol. 16:1993;729-737.
-
(1993)
PACE Pacing Clin Electrophysiol
, vol.16
, pp. 729-737
-
-
Pitney, M.R.1
May, C.D.2
Davis, M.J.3
-
11
-
-
85025297178
-
Undesirable mode switching with a Telectronics 1250 META DDDR pacemaker
-
(Letter, Comment.)
-
Wagshal A.B., Dansereau L.J., Mittleman R.S., Stephen Huang S.K. Undesirable mode switching with a Telectronics 1250 META DDDR pacemaker. (Letter, Comment.) PACE Pacing Clin Electrophysiol. 16:1993;2212-2213.
-
(1993)
PACE Pacing Clin Electrophysiol
, vol.16
, pp. 2212-2213
-
-
Wagshal, A.B.1
Dansereau, L.J.2
Mittleman, R.S.3
Stephen Huang, S.K.4
-
12
-
-
0028920952
-
Evaluation of DDD pacing with and without atrial tachy response in patients with sick sinus syndrome
-
Sutton R. Evaluation of DDD pacing with and without atrial tachy response in patients with sick sinus syndrome. Eur J Cardiac Pacing Electrophysiol. 5:1995;49-53.
-
(1995)
Eur J Cardiac Pacing Electrophysiol
, vol.5
, pp. 49-53
-
-
Sutton, R.1
|