메뉴 건너뛰기




Volumn 6, Issue 4, 1999, Pages 241-246

Fluctuations in gas exchange and cardiovascular parameters during flexible bronchoscopy

Author keywords

Arrhythmias; Blood pressure; Bronchoscopy; Cardiac index; Cardiac output; Complications; Desaturation; Heart rate; Thoracic electrical bioimpedance

Indexed keywords

ADULT; AGED; ARTERIAL GAS; ARTICLE; BLOOD PRESSURE; BRONCHOSCOPY; CLINICAL ARTICLE; FORCED EXPIRATORY VOLUME; GAS EXCHANGE; HEART INDEX; HEART OUTPUT; HEART RATE; HEART RHYTHM; HUMAN; IMPEDANCE; OXYGEN TENSION; PRIORITY JOURNAL;

EID: 0033504065     PISSN: 10708030     EISSN: None     Source Type: Journal    
DOI: 10.1097/00128594-199910000-00003     Document Type: Article
Times cited : (8)

References (48)
  • 1
    • 0015852345 scopus 로고
    • Arterial blood gas studies during fiberoptic bronchoscopy
    • Kleinholz EJ, Fussell J, McBrayer R. Arterial blood gas studies during fiberoptic bronchoscopy. Am Rev Respir Dis 1973;108: 1014.
    • (1973) Am Rev Respir Dis , vol.108 , pp. 1014
    • Kleinholz, E.J.1    Fussell, J.2    McBrayer, R.3
  • 2
  • 3
    • 0015998851 scopus 로고
    • Hypoxemia during fiberoptic bronchoscopy
    • Albertini R, Harrell JH, Moser KM. Hypoxemia during fiberoptic bronchoscopy [letter]. Chest 1974;65:117-8.
    • (1974) Chest , vol.65 , pp. 117-118
    • Albertini, R.1    Harrell, J.H.2    Moser, K.M.3
  • 5
    • 0015998851 scopus 로고
    • Hypoxemia during fiberoptic bronchoscopy
    • King EG. Hypoxemia during fiberoptic bronchoscopy. [Reply]. Chest 1974;65:117-8.
    • (1974) Chest , vol.65 , pp. 117-118
    • King, E.G.1
  • 6
    • 0016425611 scopus 로고
    • Management of arterial hypoxemia induced by fiberoptic bronchoscopy
    • Albertini RE, Harrell JH, Moser KM. Management of arterial hypoxemia induced by fiberoptic bronchoscopy Chest 1975;67:134-5.
    • (1975) Chest , vol.67 , pp. 134-135
    • Albertini, R.E.1    Harrell, J.H.2    Moser, K.M.3
  • 7
    • 0016442805 scopus 로고
    • The effect of bronchofiberscopic examination on oxygenation status
    • Dubrawsky C, Awe RJ, Jenkins DE. The effect of bronchofiberscopic examination on oxygenation status. Chest 1975;67:137-40.
    • (1975) Chest , vol.67 , pp. 137-140
    • Dubrawsky, C.1    Awe, R.J.2    Jenkins, D.E.3
  • 8
    • 0021149835 scopus 로고
    • Alterations in pulmonary mechanics and gas exchange during routine fiberoptic bronchoscopy
    • Matsushima Y, Jones RL, King EG, Moysa G, Alton JDM. Alterations in pulmonary mechanics and gas exchange during routine fiberoptic bronchoscopy. Chest 1984;86:184-8.
    • (1984) Chest , vol.86 , pp. 184-188
    • Matsushima, Y.1    Jones, R.L.2    King, E.G.3    Moysa, G.4    Alton, J.D.M.5
  • 9
    • 0028037227 scopus 로고
    • Pulse oximetry during fibreoptic bronchoscopy in local anaesthesia: Frequency of hypoxaemia and effect of oxygen supplementation
    • Milman N, Faurschou P, Grode G, Jorgensen A. Pulse oximetry during fibreoptic bronchoscopy in local anaesthesia: frequency of hypoxaemia and effect of oxygen supplementation. Respiration 1994;61:342-7.
    • (1994) Respiration , vol.61 , pp. 342-347
    • Milman, N.1    Faurschou, P.2    Grode, G.3    Jorgensen, A.4
  • 10
    • 0026730703 scopus 로고
    • Safety of bronchoalveolar lavage and bronchial biopsies in patients with asthma of variable severity
    • Van Vyve T, Chanez P, Bousquet J, Lacoste JY, Michel FB, Godard P. Safety of bronchoalveolar lavage and bronchial biopsies in patients with asthma of variable severity. Am Rev Respir Dis 1992; 146:116-21.
    • (1992) Am Rev Respir Dis , vol.146 , pp. 116-121
    • Van Vyve, T.1    Chanez, P.2    Bousquet, J.3    Lacoste, J.Y.4    Michel, F.B.5    Godard, P.6
  • 11
    • 0025974656 scopus 로고
    • Oxygen desaturation during fiberoptic bronchoscopy in pediatric patients
    • Schnapf BM. Oxygen desaturation during fiberoptic bronchoscopy in pediatric patients. Chest 1991;99:591-4.
    • (1991) Chest , vol.99 , pp. 591-594
    • Schnapf, B.M.1
  • 12
    • 0026033668 scopus 로고
    • The safety aspects of fiberoptic bronchoscopy, bronchoalveolar lavage, and endobronchial biopsy in asthma
    • Djukanovic R, Wilson JW, Lai CKW, Holgate ST, Howarth PH. The safety aspects of fiberoptic bronchoscopy, bronchoalveolar lavage, and endobronchial biopsy in asthma. Am Rev Respir Dis 1991;143:772-7.
    • (1991) Am Rev Respir Dis , vol.143 , pp. 772-777
    • Djukanovic, R.1    Wilson, J.W.2    Lai, C.K.W.3    Holgate, S.T.4    Howarth, P.H.5
  • 13
    • 0019922522 scopus 로고
    • Hemodynamic effects of flexible fiberoptic bronchoscopy performed under topical anesthesia
    • Lundgren R, Haggmark S, Reiz S. Hemodynamic effects of flexible fiberoptic bronchoscopy performed under topical anesthesia Chest 1982;82:295-9.
    • (1982) Chest , vol.82 , pp. 295-299
    • Lundgren, R.1    Haggmark, S.2    Reiz, S.3
  • 14
    • 0030461574 scopus 로고    scopus 로고
    • Analysis of the safety of bronchoscopy after recent acute myocardial infarction
    • Dweik RA, Mehta AC, Meeker DP, Arroliga AC. Analysis of the safety of bronchoscopy after recent acute myocardial infarction. Chest 1996;110:825-8.
    • (1996) Chest , vol.110 , pp. 825-828
    • Dweik, R.A.1    Mehta, A.C.2    Meeker, D.P.3    Arroliga, A.C.4
  • 15
    • 0031467911 scopus 로고    scopus 로고
    • Myocardial ischemia in sedated patients undergoing fiberoptic bronchoscopy
    • Matot I, Kramer MR, Glantz L, Drenger B, Cotev S. Myocardial ischemia in sedated patients undergoing fiberoptic bronchoscopy. Chest 1997;112:1454-8.
    • (1997) Chest , vol.112 , pp. 1454-1458
    • Matot, I.1    Kramer, M.R.2    Glantz, L.3    Drenger, B.4    Cotev, S.5
  • 16
    • 0023787022 scopus 로고
    • Comparison of cardiac output estimation by thoracic electrical bioimpendance, thermodilution and Fick methods
    • Salandin V, Zussa C, Risica G, et al. Comparison of cardiac output estimation by thoracic electrical bioimpendance, thermodilution and Fick methods. Crit Care Med 1988;16:1157-8.
    • (1988) Crit Care Med , vol.16 , pp. 1157-1158
    • Salandin, V.1    Zussa, C.2    Risica, G.3
  • 17
    • 0026001662 scopus 로고
    • Cardiac output measurement in critical care patients: Thoracic electrical bioimpendance versus thermodilution
    • Clancy TV, Norman K, Reynolds R, Covington D, Maxwell JG. Cardiac output measurement in critical care patients: thoracic electrical bioimpendance versus thermodilution. J Trauma 1991;31: 1116-20.
    • (1991) J Trauma , vol.31 , pp. 1116-1120
    • Clancy, T.V.1    Norman, K.2    Reynolds, R.3    Covington, D.4    Maxwell, J.G.5
  • 19
    • 0025611934 scopus 로고
    • Impendance cardiography for cardiac output measurement: An evaluation of accuracy and limitations
    • White SW, Quail AW, de Leeuw PW, et al. Impendance cardiography for cardiac output measurement: an evaluation of accuracy and limitations. Eur Heart J 1990;11(supp I):79-92.
    • (1990) Eur Heart J , vol.11 , Issue.1 SUPPL. , pp. 79-92
    • White, S.W.1    Quail, A.W.2    De Leeuw, P.W.3
  • 20
    • 0026613990 scopus 로고
    • Impedance cardiography using the Sramek-Bernstein method: Accuracy and variability at rest and during exercise
    • Thomas SHL. Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise. Br J Clin Pharmacol 1992;34:467-76.
    • (1992) Br J Clin Pharmacol , vol.34 , pp. 467-476
    • Thomas, S.H.L.1
  • 21
    • 0026651625 scopus 로고
    • Validity of cardiac output measurement by computer-averaged impendance cardiography, and comparison with simultaneous thermodilution determinations
    • Pickett BR, Buell JC. Validity of cardiac output measurement by computer-averaged impendance cardiography, and comparison with simultaneous thermodilution determinations. Am J Cordial 1992;69:1354-8.
    • (1992) Am J Cordial , vol.69 , pp. 1354-1358
    • Pickett, B.R.1    Buell, J.C.2
  • 22
    • 0025361628 scopus 로고
    • Noninvasive cardiac output: Simultaneous comparison of two different methods with thermodilution
    • Wong DH, Tremper KK, Stemmer EA, et al. Noninvasive cardiac output: simultaneous comparison of two different methods with thermodilution. Anesthesiology 1990;72:784-92.
    • (1990) Anesthesiology , vol.72 , pp. 784-792
    • Wong, D.H.1    Tremper, K.K.2    Stemmer, E.A.3
  • 23
    • 0025348706 scopus 로고
    • Determination of cardiac output during positive end-expiratory pressure-noninvasive electrical bioimpendance compared with standard thermodilution
    • Castor G, Molter G, Helms J, Niedermark I, Altmayer P. Determination of cardiac output during positive end-expiratory pressure-noninvasive electrical bioimpendance compared with standard thermodilution. Crit Care Med 1990;18:544-6.
    • (1990) Crit Care Med , vol.18 , pp. 544-546
    • Castor, G.1    Molter, G.2    Helms, J.3    Niedermark, I.4    Altmayer, P.5
  • 24
    • 0022979027 scopus 로고
    • Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpendance
    • Bernstein DP. Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpendance. Crit Care Med 1986;14:898-901.
    • (1986) Crit Care Med , vol.14 , pp. 898-901
    • Bernstein, D.P.1
  • 25
    • 0027979916 scopus 로고
    • Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpendance and Doppler ultrasound
    • Castor G, Klocke RK, Stoll M, Helms J, Niedermark I. Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpendance and Doppler ultrasound. Br J Anaesth 1994;72:133-8.
    • (1994) Br J Anaesth , vol.72 , pp. 133-138
    • Castor, G.1    Klocke, R.K.2    Stoll, M.3    Helms, J.4    Niedermark, I.5
  • 26
    • 0028839518 scopus 로고
    • Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpendance and thermodilution
    • Doering L, Lum E, Dracup K, Friedman A. Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpendance and thermodilution. Crit Care Med 1995; 23:1667-73.
    • (1995) Crit Care Med , vol.23 , pp. 1667-1673
    • Doering, L.1    Lum, E.2    Dracup, K.3    Friedman, A.4
  • 28
    • 0000658308 scopus 로고    scopus 로고
    • Impendance and inductance monitoring of cardiac output
    • Tobin MJ (ed). New York: McGraw-Hill
    • Bloch KE. Impendance and inductance monitoring of cardiac output. In: Tobin MJ (ed). Principles and practice of intensive care monitoring. New York: McGraw-Hill, 1998:915-30.
    • (1998) Principles and Practice of Intensive Care Monitoring , pp. 915-930
    • Bloch, K.E.1
  • 29
    • 0025124559 scopus 로고
    • Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance
    • Northridge DB, Findlay IN, Wilson J, Henderson E, Dargie HJ. Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br Heart J 1990;63:93-7.
    • (1990) Br Heart J , vol.63 , pp. 93-97
    • Northridge, D.B.1    Findlay, I.N.2    Wilson, J.3    Henderson, E.4    Dargie, H.J.5
  • 33
    • 0021237829 scopus 로고
    • Bronchoalveolar lavage: Its safety in subjects with mild asthma
    • Rankin JA, Snyder PE, Schachter EN, Matthay RA. Bronchoalveolar lavage: its safety in subjects with mild asthma. Chest 1984; 85:723-8.
    • (1984) Chest , vol.85 , pp. 723-728
    • Rankin, J.A.1    Snyder, P.E.2    Schachter, E.N.3    Matthay, R.A.4
  • 34
    • 0018138408 scopus 로고
    • Bronchofiberoscopy in asthmatics: A method for minimizing risk of complications
    • Nakhosteen JA. Bronchofiberoscopy in asthmatics: a method for minimizing risk of complications. Respiration 1978;36:112-6.
    • (1978) Respiration , vol.36 , pp. 112-116
    • Nakhosteen, J.A.1
  • 35
    • 0018085852 scopus 로고
    • Cardiorespiratory effects of flexible fiberoptic bronchoscopy in critically ill patients
    • Lindholm CE, Ollman B, Snyder JV, Millen EG, Grenvik A. Cardiorespiratory effects of flexible fiberoptic bronchoscopy in critically ill patients. Chest 1978;74:362-8.
    • (1978) Chest , vol.74 , pp. 362-368
    • Lindholm, C.E.1    Ollman, B.2    Snyder, J.V.3    Millen, E.G.4    Grenvik, A.5
  • 36
    • 0017279733 scopus 로고
    • Ventilation-perfusion alterations induced by fiberoptic bronchoscopy
    • Brach BB, Escano GG, Harrell JH, Moser KM. Ventilation-perfusion alterations induced by fiberoptic bronchoscopy. Chest 1976;69:335-7.
    • (1976) Chest , vol.69 , pp. 335-337
    • Brach, B.B.1    Escano, G.G.2    Harrell, J.H.3    Moser, K.M.4
  • 37
    • 0023845880 scopus 로고
    • The effect of bronchoalveolar lavage on bronchial responsiveness in patients with airflow obstruction
    • Kelly C, Hendrick D, Walters H. The effect of bronchoalveolar lavage on bronchial responsiveness in patients with airflow obstruction. Chest 1988;93:325-8.
    • (1988) Chest , vol.93 , pp. 325-328
    • Kelly, C.1    Hendrick, D.2    Walters, H.3
  • 38
    • 0024930786 scopus 로고
    • Flexible fiberoptic bronchoscopy does not alter airway responsiveness
    • Soderberg M, Lundgren R. Flexible fiberoptic bronchoscopy does not alter airway responsiveness. Respiration 1989;56:182-8.
    • (1989) Respiration , vol.56 , pp. 182-188
    • Soderberg, M.1    Lundgren, R.2
  • 39
    • 0025100855 scopus 로고
    • Effect of fibreoptic bronchoscopy on pulmonary function
    • Peacock AJ, Benson-Mitchell R, Godfrey R. Effect of fibreoptic bronchoscopy on pulmonary function. Thorax 1990;45:38-41.
    • (1990) Thorax , vol.45 , pp. 38-41
    • Peacock, A.J.1    Benson-Mitchell, R.2    Godfrey, R.3
  • 41
    • 0018101741 scopus 로고
    • The effect of fiberoptic bronchoscopy on cardiac rhythm
    • Shrader DL, Lakshminarayan S. The effect of fiberoptic bronchoscopy on cardiac rhythm. Chest 1978;73:821-4.
    • (1978) Chest , vol.73 , pp. 821-824
    • Shrader, D.L.1    Lakshminarayan, S.2
  • 42
    • 0019426008 scopus 로고
    • Cardiac arrhythmias: Frequency during fiberoptic bronchoscopy and correlation with hypoxemia
    • Katz AS, Michelson EL, Stawicki J, Holford FD. Cardiac arrhythmias: frequency during fiberoptic bronchoscopy and correlation with hypoxemia. Arch Intern Med 1981;141:603-6.
    • (1981) Arch Intern Med , vol.141 , pp. 603-606
    • Katz, A.S.1    Michelson, E.L.2    Stawicki, J.3    Holford, F.D.4
  • 43
  • 44
    • 0022576079 scopus 로고
    • The haemodynamic effects of bronchoscopy: Effect of pretreatment with fentanyl and alfentanil
    • Wark KJ, Lyons J, Feneck RO. The haemodynamic effects of bronchoscopy: effect of pretreatment with fentanyl and alfentanil. Anaesthesia 1986;41:162-7.
    • (1986) Anaesthesia , vol.41 , pp. 162-167
    • Wark, K.J.1    Lyons, J.2    Feneck, R.O.3
  • 45
    • 0025268538 scopus 로고
    • Fiberoptic bronchoscopy in ventilated patients: Evaluation of cardiopulmonary risk under midazolam sedation
    • Trouillet JL, Guiguet M. Gibert C, et al. Fiberoptic bronchoscopy in ventilated patients: evaluation of cardiopulmonary risk under midazolam sedation. Chest 1990;97:927-33.
    • (1990) Chest , vol.97 , pp. 927-933
    • Trouillet, J.L.1    Guiguet, M.2    Gibert, C.3
  • 46
    • 0027444654 scopus 로고
    • Cardiopulmonary effects of bronchoalveolar lavage in critically ill patients
    • Montravers P, Gauzit R, Dombret MC, Blanchet F, Desmonts JM. Cardiopulmonary effects of bronchoalveolar lavage in critically ill patients. Chest 1993;104:1541-7.
    • (1993) Chest , vol.104 , pp. 1541-1547
    • Montravers, P.1    Gauzit, R.2    Dombret, M.C.3    Blanchet, F.4    Desmonts, J.M.5
  • 47
    • 0027421573 scopus 로고
    • Effects of consecutive protected specimen brushing and bronchoalveolar lavage on gas exchange and hemodynamics in ventilated patients
    • Papazian L, Colt HG, Scemama F, Martin C, Gouin F. Effects of consecutive protected specimen brushing and bronchoalveolar lavage on gas exchange and hemodynamics in ventilated patients. Chest 1993;104:1548-52.
    • (1993) Chest , vol.104 , pp. 1548-1552
    • Papazian, L.1    Colt, H.G.2    Scemama, F.3    Martin, C.4    Gouin, F.5
  • 48
    • 0028832859 scopus 로고
    • Right ventricular function and plasma atrial natriuretic peptide levels during fiberbronchoscopic alveolar lavage in critically ill, mechanically ventilated patients
    • Bein T, Pfeifer M, Keyl C, Metz C, Taeger K. Right ventricular function and plasma atrial natriuretic peptide levels during fiberbronchoscopic alveolar lavage in critically ill, mechanically ventilated patients. Chest 1995;108:1030-5.
    • (1995) Chest , vol.108 , pp. 1030-1035
    • Bein, T.1    Pfeifer, M.2    Keyl, C.3    Metz, C.4    Taeger, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.