Volumn 92, Issue 3, 1999, Pages 210-213

Uni- and bipolar pacing threshold measurements with Capturecontrol, a new automatic pacemaker function for capture verification. Comparison of the automatic and the manual pacing threshold measurement

Author keywords

Capture verification; DDD pacemaker; Pacemaker follow up; Pacemaker function, automatic; Pacing threshold

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL ARTICLE; CLINICAL TRIAL; EVOKED RESPONSE; FEMALE; HEART PACING; HUMAN; MALE; PRIORITY JOURNAL;

EID: 0033496565     PISSN: 00086312     EISSN: None     Source Type: Journal    
DOI: 10.1159/000006973     Document Type: Article
Times cited : (4)

References (13)
  • 1
    • 0019596453 scopus 로고
    • Stimulation and sensing thresholds for cardiac pacing: Electrophysiologic and technical aspects
    • Barold SS, Ong LS, Heinle RA: Stimulation and sensing thresholds for cardiac pacing: Electrophysiologic and technical aspects. Prog Cardiovasc Dis 1981;24:1-24.
    • (1981) Prog Cardiovasc Dis , vol.24 , pp. 1-24
    • Barold, S.S.1    Ong, L.S.2    Heinle, R.A.3
  • 2
    • 0001986490 scopus 로고
    • The electrode-biointerface: Stimulation
    • Barold SS (ed): Mount Kisco, Futura
    • Stokes K, Borzin G: The electrode-biointerface: Stimulation; in Barold SS (ed): Modern Cardiac Pacing. Mount Kisco, Futura, 1985, pp 33-77.
    • (1985) Modern Cardiac Pacing , pp. 33-77
    • Stokes, K.1    Borzin, G.2
  • 3
    • 0028894430 scopus 로고
    • Programming of the pacing impulse in pacemakers connected to steroid lead systems
    • Schuchert A, Cappato R, Kuck K-H, et al: Programming of the pacing impulse in pacemakers connected to steroid lead systems. PACE 1995; 18:318-322.
    • (1995) PACE , vol.18 , pp. 318-322
    • Schuchert, A.1    Cappato, R.2    Kuck, K.-H.3
  • 4
    • 0031826755 scopus 로고    scopus 로고
    • Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: A multicenter study
    • Clarke M, Liu B, Schüller H, et al: Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: A multicenter study. PACE 1998;21:1567-1575.
    • (1998) PACE , vol.21 , pp. 1567-1575
    • Clarke, M.1    Liu, B.2    Schüller, H.3
  • 6
    • 0024426356 scopus 로고
    • Initial clinical experience with a rate responsive pacemaker
    • Singer I, Olash J, Brennan F, et al: Initial clinical experience with a rate responsive pacemaker. PACE 1989;12:1458-1464.
    • (1989) PACE , vol.12 , pp. 1458-1464
    • Singer, I.1    Olash, J.2    Brennan, F.3
  • 7
    • 0001427070 scopus 로고    scopus 로고
    • Evaluation of Autocapture algorithm
    • Cercas A, Gascon D, Leal J, et al: Evaluation of Autocapture algorithm (abstract). PACE 1997; 20:1189.
    • (1997) PACE , vol.20 , pp. 1189
    • Cercas, A.1    Gascon, D.2    Leal, J.3
  • 8
    • 0001515773 scopus 로고    scopus 로고
    • Clinical experiences with the evoked response and polarization testing in the Microny/Regency SR+ pacemakers: Clinical efficacy of Autocapture
    • Greenberg S, Crossley G, Ellenbogen K, et al: Clinical experiences with the evoked response and polarization testing in the Microny/Regency SR+ pacemakers: Clinical efficacy of Autocapture (abstract). PACE 1997;20:1172.
    • (1997) PACE , vol.20 , pp. 1172
    • Greenberg, S.1    Crossley, G.2    Ellenbogen, K.3
  • 9
    • 0000716351 scopus 로고    scopus 로고
    • How effective is Autocapture? - Clinical experience with Regency SR + 2400L pacemaker and 1450T lead
    • Riddell F, Biosa R, Richardson V: How effective is Autocapture? - Clinical experience with Regency SR + 2400L pacemaker and 1450T lead (abstract). PACE 1998;21:955.
    • (1998) PACE , vol.21 , pp. 955
    • Riddell, F.1    Biosa, R.2    Richardson, V.3
  • 10
    • 0001515772 scopus 로고    scopus 로고
    • Initial multi-centered North American experience with the Autocapture pacing system
    • Lau C: Initial multi-centered North American experience with the Autocapture pacing system (abstract). PACE 1997;20:1172.
    • (1997) PACE , vol.20 , pp. 1172
    • Lau, C.1
  • 11
    • 0000609715 scopus 로고    scopus 로고
    • Evaluation of the compatibility of various bipolar pacing leads with Autocapture
    • Kacet S, Jarwe M, Klug D: Evaluation of the compatibility of various bipolar pacing leads with Autocapture (abstract). PACE 1998;21: 825.
    • (1998) PACE , vol.21 , pp. 825
    • Kacet, S.1    Jarwe, M.2    Klug, D.3
  • 12
    • 0000198851 scopus 로고    scopus 로고
    • Polarization signal and evoked response characteristics in current endocardial electrodes
    • Lau C, Nishimura SC, Philippon F, et al: Polarization signal and evoked response characteristics in current endocardial electrodes (abstract). PACE 1998;21:841.
    • (1998) PACE , vol.21 , pp. 841
    • Lau, C.1    Nishimura, S.C.2    Philippon, F.3
  • 13
    • 0342926464 scopus 로고    scopus 로고
    • Autocapture: Is reprogramming of the evoked response sensitivity necessary after hospital discharge?
    • Schuchert A, Meinertz T on behalf of the AUTOCAP Investigators: Autocapture: Is reprogramming of the evoked response sensitivity necessary after hospital discharge? (abstract). PACE 1999;22:872.
    • (1999) PACE , vol.22 , pp. 872
    • Schuchert, A.1    Meinertz, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.