메뉴 건너뛰기




Volumn 21, Issue 4, 1999, Pages 243-258

Effects of transmit focusing on finite amplitude distortion based second harmonic generation

Author keywords

Acoustic amplitude distribution; Dynamic transmit focusing; Finite amplitude distortion; Tissue harmonic imaging; Ultrasonic imaging

Indexed keywords

ACOUSTIC FIELDS; FOCUSING; HARMONIC ANALYSIS; HARMONIC GENERATION; HYDROPHONES; IMAGING SYSTEMS; NONLINEAR OPTICS; TRANSDUCERS; ULTRASONIC IMAGING;

EID: 0033492442     PISSN: 01617346     EISSN: None     Source Type: Journal    
DOI: 10.1177/016173469902100401     Document Type: Article
Times cited : (16)

References (16)
  • 1
    • 0030849582 scopus 로고    scopus 로고
    • Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging
    • Christopher, T., Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging, IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 44, 125-139 (1997).
    • (1997) IEEE Trans. Ultrason. Ferroelec. Freq. Contr. , vol.44 , pp. 125-139
    • Christopher, T.1
  • 2
    • 0031699682 scopus 로고    scopus 로고
    • Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging
    • Christopher, T., Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging, IEEE Trans. Ultrason. Ferroelec. Freq. Contr., 45 158-162 (1998).
    • (1998) IEEE Trans. Ultrason. Ferroelec. Freq. Contr. , vol.45 , pp. 158-162
    • Christopher, T.1
  • 3
    • 0032904188 scopus 로고    scopus 로고
    • Pulse compression for finite amplitude distortion based harmonic imaging using coded waveforms
    • Li, P.-C., Pulse compression for finite amplitude distortion based harmonic imaging using coded waveforms, Ultrasonic Imaging 21, 1-17 (1999).
    • (1999) Ultrasonic Imaging , vol.21 , pp. 1-17
    • Li, P.-C.1
  • 8
    • 0015722111 scopus 로고
    • Ultrasound axicon: A device for focusing over a large depth
    • Burckhardt, C.B., Hoffman, H. and Grandchamp, P.A., Ultrasound axicon: a device for focusing over a large depth, J. Acoust. Soc. Amer. 54, 1628-1630 (1973).
    • (1973) J. Acoust. Soc. Amer. , vol.54 , pp. 1628-1630
    • Burckhardt, C.B.1    Hoffman, H.2    Grandchamp, P.A.3
  • 9
    • 0019523621 scopus 로고
    • The conical scanner: A two transducer ultrasound scatter image technique
    • Foster, F.S., Patterson, M.S., Arditi, M. and Hunt, J.W., The conical scanner: a two transducer ultrasound scatter image technique. Ultrasonic Imaging 3, 62-82 (1981).
    • (1981) Ultrasonic Imaging , vol.3 , pp. 62-82
    • Foster, F.S.1    Patterson, M.S.2    Arditi, M.3    Hunt, J.W.4
  • 10
    • 0029780605 scopus 로고    scopus 로고
    • A new coded excitation ultrasound imaging system-part I: Basic principles
    • Shen, J. and Ebbini, E.S., A new coded excitation ultrasound imaging system-part I: basic principles, IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 43, 131-140 (1996).
    • (1996) IEEE Trans. Ultrason. Ferroelec. Freq. Contr. , vol.43 , pp. 131-140
    • Shen, J.1    Ebbini, E.S.2
  • 11
    • 0030373263 scopus 로고    scopus 로고
    • Extended focal depth imaging for medical ultrasound
    • Hossack, J.A., Extended focal depth imaging for medical ultrasound, in Proc. IEEE Ultrason. Symp., pp. 1535-1540 (1996).
    • (1996) Proc. IEEE Ultrason. Symp. , pp. 1535-1540
    • Hossack, J.A.1
  • 12
  • 14
    • 0025822618 scopus 로고
    • New approaches to nonlinear diffractive field propagation
    • Christopher, P.T., and Parker, K.J., New approaches to nonlinear diffractive field propagation, J. Acoust. Soc. Amer. 90, 488-499 (1991).
    • (1991) J. Acoust. Soc. Amer. , vol.90 , pp. 488-499
    • Christopher, P.T.1    Parker, K.J.2
  • 15
    • 0021806081 scopus 로고
    • Determination of the nonlinearity parameter B/A of biological media
    • Law, W.K., Frizzell, L.A., and Dunn, F., Determination of the nonlinearity parameter B/A of biological media, Ultrasound Med. Biol. 11, 307-318 (1985).
    • (1985) Ultrasound Med. Biol. , vol.11 , pp. 307-318
    • Law, W.K.1    Frizzell, L.A.2    Dunn, F.3
  • 16
    • 0032624656 scopus 로고    scopus 로고
    • Source prebiasing for improved second harmonic bubble-response imaging
    • Christopher, T., Source prebiasing for improved second harmonic bubble-response imaging, IEEE Trans. Ultrason. Ferroelec. Freq. Contr., 46, 556-563 (1999).
    • (1999) IEEE Trans. Ultrason. Ferroelec. Freq. Contr. , vol.46 , pp. 556-563
    • Christopher, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.