메뉴 건너뛰기




Volumn 20, Issue 6, 1999, Pages 726-728

Osteomyelitis, lateral sinus thrombosis, and temporal lobe infarction caused by infection of a percutaneous Cochlear implant

Author keywords

Cochlear implants; Complications; Lateral sinus thrombosis; Percutaneous

Indexed keywords

ADULT; ARTICLE; BONE SCREW; BRAIN INFARCTION; CASE REPORT; CAVERNOUS SINUS THROMBOSIS; COCHLEA PROSTHESIS; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; INFECTION; OSTEOMYELITIS; PRIORITY JOURNAL; TEMPORAL LOBE;

EID: 0033490839     PISSN: 01929763     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (20)

References (15)
  • 2
    • 0023811644 scopus 로고
    • Medical or surgical complications related to the Nucleus multichannel cochlear implant
    • Cohen N, Huffman R, Strohshein M. Medical or surgical complications related to the Nucleus multichannel cochlear implant. Ann Olol Rhinol Laryngol 1988;97:8-13.
    • (1988) Ann Olol Rhinol Laryngol , vol.97 , pp. 8-13
    • Cohen, N.1    Huffman, R.2    Strohshein, M.3
  • 3
    • 0025951786 scopus 로고
    • Complications of cochlear implant surgery in adults and children
    • Cohen N, Hoffman R. Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 1991 ; 100:708-11.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 708-711
    • Cohen, N.1    Hoffman, R.2
  • 4
    • 0029083132 scopus 로고
    • Complications of cochlear implant surgery
    • Hoffman R, Cohen N. Complications of cochlear implant surgery. Ann Otol Rhinol Laryngol 1995;166(Supple):420-2.
    • (1995) Ann Otol Rhinol Laryngol , vol.166 , Issue.SUPPLE , pp. 420-422
    • Hoffman, R.1    Cohen, N.2
  • 5
    • 0030918214 scopus 로고    scopus 로고
    • Cochlear implantation in a district general hospital: Problems and complications in the first five years
    • Collins M, Hawthorne MH, el-Hmd K. Cochlear implantation in a district general hospital: problems and complications in the first five years. J Laryngol Otol 1997;111:325-32.
    • (1997) J Laryngol Otol , vol.111 , pp. 325-332
    • Collins, M.1    Hawthorne, M.H.2    El-Hmd, K.3
  • 6
    • 0025053998 scopus 로고
    • Percutaneous pedestal in cochlear implantation
    • Parkin J. Percutaneous pedestal in cochlear implantation. Ann Otol Rhinol Laryngol 1990;99:796-801.
    • (1990) Ann Otol Rhinol Laryngol , vol.99 , pp. 796-801
    • Parkin, J.1
  • 7
    • 0028226302 scopus 로고
    • Multichannel cochlear implantation with percutaneous pedestal
    • Parkin J, Parkin M. Multichannel cochlear implantation with percutaneous pedestal. ENTJ 1994;73(3):156-65.
    • (1994) ENTJ , vol.73 , Issue.3 , pp. 156-165
    • Parkin, J.1    Parkin, M.2
  • 8
    • 0026019746 scopus 로고
    • Surgical complications with the cochlear multiple channel intracochlear implant: Experience at Hanover and Melbourne
    • Webb R, Lehnhardt E, Clark GM, et al. Surgical complications with the cochlear multiple channel intracochlear implant: experience at Hanover and Melbourne. Ann Otol Rhinol Laryngol 1991:100:131-6.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 131-136
    • Webb, R.1    Lehnhardt, E.2    Clark, G.M.3
  • 10
    • 0027022749 scopus 로고
    • A retrospective study of osseointegrated skin"2Dpenetrating titanium fixtures used for retaining facial prostheses
    • Jacobsson M, Tjellstrom A, Fine L, et al. A retrospective study of osseointegrated skin"2Dpenetrating titanium fixtures used for retaining facial prostheses. Int J Maxillofacial Implant 1992;7(4):523-8.
    • (1992) Int J Maxillofacial Implant , vol.7 , Issue.4 , pp. 523-528
    • Jacobsson, M.1    Tjellstrom, A.2    Fine, L.3
  • 11
    • 0027970485 scopus 로고
    • Persistent irritation of the soft tissue around an osseointegrated titanium implant
    • Holgers K, Thomsen P, Tjellstrom A. Persistent irritation of the soft tissue around an osseointegrated titanium implant. Scand J Plast Reconstr Hand Surg 1994;28:225-230.
    • (1994) Scand J Plast Reconstr Hand Surg , vol.28 , pp. 225-230
    • Holgers, K.1    Thomsen, P.2    Tjellstrom, A.3
  • 12
    • 0027323048 scopus 로고
    • Tissue integrated prostheses in the rehabilitation of auricular defects: Results with percutaneous mastoid implants
    • Niparko J, Langman AW, Cutler DS, et al. Tissue integrated prostheses in the rehabilitation of auricular defects: results with percutaneous mastoid implants. Am J Otol 1993;14(4):343-8.
    • (1993) Am J Otol , vol.14 , Issue.4 , pp. 343-348
    • Niparko, J.1    Langman, A.W.2    Cutler, D.S.3
  • 13
    • 0023907585 scopus 로고
    • Soft tissue reactions around percutaneous implants: A clinical study of soft tissue conditions around skin penetrating titanium implants for bone anchored hearing aids
    • Holgers K, Tjellstrom A, Bjursten LM, et al. Soft tissue reactions around percutaneous implants: a clinical study of soft tissue conditions around skin penetrating titanium implants for bone anchored hearing aids. Am J Otol 1988;9(1):56-9.
    • (1988) Am J Otol , vol.9 , Issue.1 , pp. 56-59
    • Holgers, K.1    Tjellstrom, A.2    Bjursten, L.M.3
  • 14
    • 0025201069 scopus 로고
    • Surgical and nonsurgical complications associated with cochlear prosthesis implantation
    • Windmill I, Martinez SA, Nolph MB, et al. Surgical and nonsurgical complications associated with cochlear prosthesis implantation. Am J Otol 1990;11(6):415-20.
    • (1990) Am J Otol , vol.11 , Issue.6 , pp. 415-420
    • Windmill, I.1    Martinez, S.A.2    Nolph, M.B.3
  • 15
    • 0030798095 scopus 로고    scopus 로고
    • Use of magnetic resonance imaging and magnetic resonance angiography in diagnosis of sigmoid sinus thrombosis
    • Davison S, Facer GW, McGough PF, et al. Use of magnetic resonance imaging and magnetic resonance angiography in diagnosis of sigmoid sinus thrombosis. ENT J 1997:76:436-41.
    • (1997) ENT J , vol.76 , pp. 436-441
    • Davison, S.1    Facer, G.W.2    McGough, P.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.